Resultatrapport hematologi, utsendelse 2/2014

Like dokumenter
Resultatrapport hematologi, utsendelse 4/2015

Resultatrapport hematologi, utsendelse 4/2011

Resultatrapport hematologi, utsendelse 4/2011

Resultatrapport hematologi, utsendelse 2/2011

Resultatrapport hematologi, utsendelse 3/2011

Resultatrapport hematologi, utsendelse 1/2012

Resultatrapport hematologi, utsendelse 4/2013

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 1/ 2015

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 2/ 2015

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 3 / 2015

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 4 / 2015

NKKS RAPPORTVEILEDER FOR NOKLUS PROGRAM

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 2/ 2016

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 4 / 2016

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 32/ 2013

Blodutstryk kan avsløre leukemi

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 22/ 2013

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 2 / 2017

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 2/2012

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 2/2011

Erfaringer med EKV. Marthe Wedø Aune NOKLUS & Avdeling for immunologi-og transfusjonsmedisin. Mars 2009

RESULTATRAPPORT KOAGULASJON, UTSENDELSE 3 / 2016

EQSDocument Side 1 av 13

EQSDocument Side 1 av 12

Databehandlingen for de ovennevnte EKV programmene blir utført på samme dataprogram, og utseendet av rapportene blir derfor tilnærmet likt.

Ekstern kvalitetskontroll for pasientnær analysering

Autovalidering Våre erfaringer etter 1 års bruk

Anne Christin Breivik Avdelingsingeniør NOKLUS

Mellominstrumentell. Eksempler fra medisinsk biokjemi. Utarbeidet av overlege Sverre Marstein og bioingeniør Torill Odden Sentrallaboratoriet

PRINSIPPER PENTRA 120

Analysekvalitet på urinalbuminanalysen

Samkjøring av instrumenterhematologi. Foredraget vil omhandle. Hvordan sikre samkjørte hematologi instrumenter?

Hvilke konsekvenser skal en BLAST melding ha for laboratoriet?

NKKS RAPPORTVEILEDER FOR DEKS-PROGRAM

Analysekvaliteten på U-AKR og S-kreatinin (egfr)

Percentiler / Flagger

NKKS RAPPORTVEILEDER FOR LABQUALITY-PROGRAM

NORIP referansegrenser for differensialtelling. Pål Rustad

CRP - hvordan lages et nytt EQA-program?

Flytskjema. - for behandling av avvikende EKV-resultat. Gunn B B Kristensen, NKK møte Hva skal jeg snakke om?

HØGSKOLEN I SØR-TRØNDELAG

Anne Christin Breivik

Olgunn S. Lid, seksjonsleder for Seksjon for hematologi-og koagulasjonsanalyser, Lab.for klinisk biokjemi,

Hematologiinstrumenter. Anvendelse og tolkning av resultater

NKKS RAPPORTVEILEDER GENERELL DEL

Konsolideringsmodell hematologi St Olavs hospital HF Avdeling for immunologi- og transfusjonsmedisin St Olavs Hospital HF Trondheim,

Kontinuerlig opplæring - hematologi

SYSMEX XS-1000i. Analyseprinsipper

Percentiler-programmet - en liten smakebit. Solstrand mars 2018

HbA1c. Kvalitetskontroll og kva som er viktig for oss ved legekontorene når HbA1c skal brukast til å stille diagnosen diabetes

Foredraget vil omhandle:

SYSMEX KX-21 HEMATOLOGIANALYSATOR FRA MEDINOR

Nasjonale kvalitetsindikatorer

Hematologisk kvalitetskontroll av blodkomponenter

Analysekvalitet HbA1c.

Ringegrenser i Norge. Kristin M Aakre Lab for klinisk biokjemi Haukeland universitetssykehus

Bruk av pasientprøver til kvalitetsovervåking Percentiler programmet

Måleprinsipper. Advia. 3 ulike prinsipper benyttes: Instrumentet har 5 kanaler. 2 flowceller benyttes til måling m

Avdeling for medisinsk biokjemi, St. Olavs Hospital. Nr 56 Oktober 2005

STUDENTKURS HEMATOLOGISK DIAGNOSTIKK

Ekstern kvalitetskontroll Blodkomponenter

Hematologi og tolkning av cytogrammer

Medisinsk biokjemi, 2 nivå Utsendelse

EKV-kategorier. Hva er det?

Krav til analysekvalitet sett i sammenheng med Ekstern Kvalitetsvurdering (EKV)

Tolkning av resultater fra EKV program

Olgunn S. Lid, seksjonsleder Seksjon for hematologi- og koagulasjonsanalyser Haukeland universitetssykehus

To k a s u s e r viser at det er viktig å

IQC/metodevalidering: Kartlegging av impresisjon og middelverdi (target).

Albumin og kreatinin i urin 2, 2016

Nytt frå NKK og EKV rapportane

Analyse av urin-albumin og urin-albumin/kreatinin-ratio:

Meningsmåling Nordmøre og Romsdal

Albumin og kreatinin i urin 1, 2017

Rapport for Native sera 2013

Side 1 Versjon

in T e r N at i o N a l society for laboratory

Avvikende trombocytter

ESTIMATION OF PREANALYTICAL UNCERTAINTY IN CLINICAL CHEMISTRY

Analytisk ved Biologisk Total RCV Klinisk Kjemi Variasjon Konsentrasjon Variasjon Variasjon p<0,05 intraindividuell [%] [%] [%] [%]

Hva skiller ulike hematologiinstrumenter? Når kommer de til kort? Marthe Wedø Aune Avd. for Medisinsk biokjemi NKK møte, mars 2016

Analytisk ved Biologisk Total Klinisk Kjemi Variasjon Konsentrasjon Variasjon Variasjon intraindividuell [%] [%] [%]

Ekstern kvalitetsvurdering NKK i samarbeid med Labquality, Noklus, DEKS, EQUALIS, ECAT, Instand, RfB-dgkl og UKNEQAS PROGRAM OG PÅMELDING FOR 2017

«Blasts?» -et nyttig flagg?

NKK Workshop 2013 Gruppeoppgave Del 1

Klinikk for diagnostikk Avdeling for medisinsk biokjemi Seksjon Molde

Akseptgrenser. De grenser et EKV-resultat bør ligge innenfor for at resultatet skal vurderes som akseptabelt. Akseptgrenser i EKV

Ekstern kvalitetsvurdering

MASTER I IDRETTSVITENSKAP 2014/2016. Utsatt individuell skriftlig eksamen. STA 400- Statistikk. Mandag 24. august 2015 kl

Kva var gjort på forhånd?

HØGSKOLEN I SØR-TRØNDELAG

Løsningsforslag til obligatorisk innlevering 3.

Analytisk ved Biologisk Total RCV Klinisk Kjemi Variasjon Konsentrasjon Variasjon Variasjon p<0,05 intraindividuell [%] [%] [%] [%]

EQA-program for Nasjonale. kvalitetsindikatorer. Fagmøte Solstrand Gunn B B Kristensen

Statistikk, FO242N, AMMT, HiST 2. årskurs, 30. mai 2007 side 1 ( av 8) LØSNINGSFORSLAG HØGSKOLEN I SØR-TRØNDELAG

Vedlegg. Foto: Annbjørg Ø. Kristoffersen

EQAnord Hemolyseprosjekt

Ekstern kvalitetsvurdering

Løsningsforslag Til Statlab 5

Skiftenoteringsskjema for ny gjødslingsplan

Transkript:

Sykehuset Levanger Avdeling for Laboratoriemedisin v/ragnhild Elgseter Kirkegata 2 A 7600 LEVANGER Bergen, 03072014 nr: 5237 NKK-nr: 2553 Resultatrapport hematologi, utsendelse 2/2014 Vedlagt følger resultater fra den andre kontrollutsendelsen for hematologi i 2014 (sendt ut 3 juni) 79 norske sykehuslaboratorier var påmeldt med til sammen 118 instrument Alle deltakerne rapporterte tallsvar ved utsendelsen Kontrollmaterialet Glass 1: Glass 2: Lett stabilisert, fersktappet CPD-adeninblod brukt til telling av blodlegemer og retikulocytter Fersktappet K 2 -EDTA-blod uten tilsetninger brukt til differensialtellingene Kontrollmaterialet i glass 1 og glass 2 var tappet fra to forskjellige blodgivere Tillagt verdi Median for metodegruppene benyttes vanligvis som tillagt verdi Er n < 5 i en metodegruppe, benyttes median for alle metodegrupper samlet Dersom det er nivåforskjeller for en komponent, kan median for alle metodegrupper samlet være et relativt usikkert estimat for tillagt verdi Ta hensyn til dette ved tolking av resultatene Dersom n < 5 for en retikulocytt-metodegruppe eller for 3-parts DIFF-metodene, kan vi ikke gi tillagt verdi basert på alle metodegruppene samlet pga betydelige metodeforskjeller for disse komponentene Akseptgrenser Kontrollene skal analyseres i duplikat og gjennomsnittet sammenlignes med tillagt verdi for metodegruppen Tabellen nedenfor viser akseptgrensene for de ulike komponentene Om det er stor forskjell mellom duplikatmålingene, vil snittet gi et usikkert grunnlag for vurdering av riktigheten Deltakere med upresise målinger får en kommentar om dette Komponent Akseptgrenser % Komponent Akseptgrenser % Leukocytter 10 Middel MCHC 10 Erytrocytter 5 Neutr 15 Hb 5 Lymf 15 EVF 10 Mono 30 MCV 10 Eos 50 MCH 10 Baso 200 MCHC 10 LUC 50 Trombocytter 20 Retikulocytter 20 Middel MCV 10 Ret-He/CHr/MCHr 10 Middel MCH 10 E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

Kommentar til resultatene Det er 118 instrument som deltar i dette kontrollprogrammet Den største instrumentgruppen er Sysmex SE/SF/XE/XS/XT+XN med 54 instrumenter (45 %), og resultatene fra denne gruppen har dermed stor innvirkning på beregningene for alle instrumentene samlet («Alle»-gruppen) Ta hensyn til dette i oppsummeringen under Celletellinger Det er gode resultater for celletellingene ved denne utsendelsen CV er lavere enn gjennomsnittlig CV for de 3 siste årene for LPK, EPK, Hb OG TPK CV Alle for EPK (1,7 %) og Hb (1,5 %) er lavere enn vi tidligere har sett i denne perioden Dette til tross for at det er signifikante forskjeller mellom instrumentgrupper for begge komponenter Det var <5 deltakere fra gruppene UniCel og Cell-Dyn 3200/Ruby som rapporterte trombocyttresultater, disse instrumentgruppene er derfor ikke tatt med i kommentaren som følger Det er godt samsvar mellom medianverdiene til de ulike instrumentgruppene (Fig 1) Instrumentgruppene Cell-Dyn Sapphire og Sysmex-gruppene har likevel en median som er signifikant forskjellig fra median alle Differansen mellom disse to gruppene er på 9 trombocyttenheter Ingen deltakere som rapporterte resultat for trombocytter fikk resultater utenfor akseptgrensen på 20 % Nr Metodegruppe Median n Differanse SDdiff Konfidensintervall (95%) Sign for høy/lav? 1 ABX Micros CRP 200, Advia 60 146,5 6-1,800 4,0160-12,044-8,444 Nei 2 ABX Pentra 80/XL80/DX120 150 10 1,700 1,7245-2,112-5,512 Nei 3 Advia 120, 2120/2120i 149,5 19 1,200 1,4912-1,889-4,289 Nei 4 Cell-Dyn Sapphire 154 19 5,700 1,8109 1,931-9,469 Ja, høy Sysmex K-4500, KX -21, KX- 21N, Poch- 5 100i, XP-300 145 5-3,300 2,7439-10,761-4,161 Nei Sysmex XE-2100/5000, XT- 6 2000i/1800i, XS-1000i, XN-1000 144,8 52-3,500 1,1421-5,780 - -1,220 Ja, lav 7 Alle TPK 148,3 116 Refgruppe - Fig 1: Figuren viser medianverdiene med konfidensintervall for komponenten TPK, konsentrasjon i 10 9 /L Differensialtellinger Blodutstryk av Glass 2 viste eosinofili, og dette kunne også sees i deltakernes resultater Vi finner signifikante forskjeller mellom ABX Pentra 80/ XL80/ DX120 og Advia 120/ 2120/2120i, hvor ABX Pentra 80/ XL80/ DX120 ga verdier lavere enn «Alle», mens Advia 120/ 2120/2120i ga verdier høyere enn «Alle» (Fig 2) Forskjellen var på 2,5 neutrofil-enheter Også for lymfocyttene fant vi signifikante forskjeller mellom flere instrumentgrupper Den største forskjellen var, som for neutrofile, mellom ABX Pentra 80/ XL80/ DX120 og Advia 120/ 2120/2120i, men her ga ABX Pentra 80/ XL80/ DX120 høyere mens Advia 120/ 2120/2120i ga lavere verdier enn «Alle» (Fig 3) Forskjellen var på 5,4 lymfocyttenheter Nr Metodegruppe Median n Differanse SDdiff Konfidensintervall (95%) Sign for høy/lav? 1 ABX Pentra 80/XL80/DX120 56,83 8-2,570 0,6022-3,963 - -1,177 Ja, lav 2 Advia 120, 2120/2120i 62,3 19 2,900 0,4056 2,062-3,738 Ja, høy 3 Cell-Dyn Sapphire 59,15 19-0,250 0,4439-1,170-0,670 Nei Sysmex XE-2100/5000, XT- 4 2000i/1800i, XS-1000i, XN-1000 59,35 50-0,050 0,2454-0,538-0,438 Nei 5 Alle 5-part Neut 59,4 101 Refgruppe - Fig 2: Figuren viser medianverdiene med konfidensintervall for komponenten neutrofile granulocytter, konsentrasjon i % Nr Metodegruppe Median n Differanse SDdiff Konfidensintervall (95%) Sign for høy/lav? 1 ABX Pentra 80/XL80/DX120 27,7 8 2,820 0,5151 1,634-4,006 Ja, høy 2 Advia 120, 2120/2120i 22,35 19-2,530 0,2654-3,069 - -1,991 Ja, lav 3 Cell-Dyn Sapphire 26,55 19 1,670 0,3226 1,008-2,332 Ja, høy Sysmex XE-2100/5000, XT- 4 2000i/1800i, XS-1000i, XN-1000 24,75 51-0,130 0,2290-0,585-0,325 Nei 5 Alle 5-part Lymf 24,88 102 Refgruppe - Fig3: Figuren viser medianverdiene med konfidensintervall for komponenten lymfocytter, konsentrasjon i % E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

Retikulocytter 4 % av deltakerne (3 stk) som rapporterte retikulocytter har verdier som faller utenfor akseptgrensene på 20 % Dette er færre enn ved forrige utsendelse (9 %) Det er ingen instrumentgrupper som skiller seg ut i denne sammenheng Det er godt samsvar mellom medianverdiene til Advia 120, 2120/2120i, Cell-Dyn Sapphire og Sysmex XNgruppen (Fig 6) Sysmex XE-2100/5000,XT-2000i gir som tidligere lavere verdier Det største avviket i trimmet median er denne gangen mellom Advia 120, 2120/2120i og Sysmex XE-2100/5000,XT-2000i og er på 0,55 reticulocyttenheter Nr Metodegruppe Median n Differanse SDdiff Konfidensintervall (95%) Sign for høy/lav? 1 Advia 120, 2120/2120i 1,9 6 0,150 0,1555-0,245-0,545 Nei 2 Cell-Dyn Sapphire 1,85 17 0,100 0,0462 0,005-0,195 Ja, høy 3 Sysmex XE-2100/5000, XT-2000i 1,35 24-0,400 0,0436-0,488 - -0,312 Ja, lav 4 Sysmex XN 1,85 19 0,100 0,0409 0,017-0,183 Ja, høy 5 Alle retic 1,75 66 Refgruppe - Fig 1: Figuren viser medianverdiene med konfidensintervall for komponenten retikulocytter, konsentrasjon i % Generell kommentar til deltaker E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

Forklaringer til rapporten Histogrammet Resultat for egen metode vises som mørke/blå stolper Resultat fra alle metoder samlet vises som grå/orange bakgrunn Den horisontale linjen under histogrammet viser akseptområdet (dvs tillagt verdi ± akseptgrenser) Tillagt verdi vises som en liten vertikal strek, og er den verdien laboratoriet blir sammenliknet med Symbolet viser gjennomsnittet av duplikatmålingene : Median: Median etter eksklusjon SD: Standardavvik for gjennomsnitt av duplikatmålingene CV: Variasjonskoeffisient (%) for gjennomsnitt av duplikatmålingene n: Antall resultat med i beregningene n x : Antall ekskluderte resultat grunnet uriktige eller upresise resultat, eller ikke analysert i duplikat Hvis n < 5 oppgis ikke SD og CV Historikk, avvik i % I plottet vises egen snittverdi som prosentavvik fra tillagt verdi Grått rektangel angir akseptområde Akseptgrensene for aktuelle komponent er angitt under plottet viser snittverdi for de ulike utsendelsene kronologisk viser snittverdi som ligger utenfor eller opp mot utkanten av plottet Historikk, avvik i konsentrasjonsenheter I plottet vises egen snittverdi som avvik i konsentrasjonsenheter fra tillagt verdi Akseptområdet vises i grått Resultat for aktuell utsendelse er markert med en ring rundt punktet, tidligere resultat er markert med Benevning for aktuelle komponent er angitt under plottet Historikken inneholder opplysninger om instrument, og forklaring til kortkodene i historikken følger i tabellen nedenfor: Instrument Kode Instrument Kode ABX MicrosEMI CRP ABXMEC Sysmex K4500 SYSK4500 ABX Pentra 80 ABXP80 Sysmex KX-21 SYSKX21 ABX Pentra DX 120 ABXPDX120 Sysmex PocH-100i SYSP100i ABX Pentra XL 80 ABXPXL80 Sysmex XE-2100 SYSXE2100 Advia 120 ADV120 Sysmex XE-5000 SYSXE5000 Advia 2120 ADV2120 Sysmex XN-serien SYSXN Advia 2120 i ADV2120i Sysmex XP-300 SYSXP300 Advia 60 ADV60 Sysmex XS-1000i SYSKS1000i Cell-Dyn 3200 CD3200 Sysmex XT-1800i SYSXT1800i Cell-Dyn Ruby CDR Sysmex XT-2000i SYSXT2000i Cell-Dyn Sapphire CDSAP UniCel DxH 800 UCDxH800 Ytterligere forklaringer til de statistiske beregningene finner du i NKKs rapportveileder og i Nina Gade Christensens Statistisk veileder fra nov 2002 Med vennlig hilsen Sverre Sandberg Leder Marthe Wedø Aune Konsulent Gunn B B Kristensen Kvalitetskonsulent NKK Hege Alvheim Avdelingsingeniør E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

B-Leukocytter, 10 9 /L Sysmex XT-2000i [Sysmex] Eget snitt: 5,40(5,4-5,4) Avvik fra tillagt verdi: -4,4% - Akseptomr (tillagt verdi ± 10%): 5,09-6,22 Alle LPK 2014,2 5,65 5,40-4,4 SYSXT2000i 2014,1 5,05 4,85-4,0 SYSXT2000i 2013,4 5,20 5,05-2,9 SYSXT2000i 2013,3 3,85 3,90 1,3 SYSXT2000i 2013,2 3,85 3,85 0,0 SYSXT2000i 2013,1 4,15 4,15 0,0 SYSXT2000i 2012,4 3,50 3,50 0,0 SYSXT2000i 2012,3 3,65 3,70 1,4 SYSXT2000i 2012,2 4,75 5,00 5,3 SYSXT2000i 2012,1 4,95 5,05 2,0 SYSXT2000i 2011,4 3,55 3,60 1,4 SYSXT2000i 2011,3 6,30 6,15-2,4 SYSXT2000i 2011,2 5,05 4,75-5,9 SYSXT2000i 2011,1 3,60 3,55-1,4 SYSXT2000i 2010,4 6,00 6,00 0,0 SYSXT2000i 2010,3 2,50 2,60 4,0 SYSXT2000i ABX Micros CRP 200, Advia 60 5,40 0,082 1,5 6 0 ABX Pentra 80/XL80/DX120 5,60 0,189 3,4 9 1 Advia 120, 2120/2120i 5,65 0,182 3,2 18 1 Cell-Dyn Sapphire 5,65 0,110 1,9 19 0 Cell-Dyn 3200, Ruby 5,50 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 5,70 0,214 3,8 5 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 5,65 0,142 2,5 54 0 UniCel DxH 800 5,75 2 0 Alle LPK 5,65 0,156 2,8 116 2 B-Erytrocytter, 10 12 /L Sysmex XT-2000i [Sysmex] Eget snitt: 4,580(4,58-4,58) Avvik fra tillagt verdi: -0,4% - Akseptomr (tillagt verdi ± 5%): 4,368-4,828 Alle EPK 2014,2 4,598 4,580-0,4 SYSXT2000i 2014,1 3,550 3,575 0,7 SYSXT2000i 2013,4 4,300 4,235-1,5 SYSXT2000i 2013,3 3,598 3,625 0,8 SYSXT2000i 2013,2 3,500 3,400-2,9 SYSXT2000i 2013,1 4,155 4,115-1,0 SYSXT2000i 2012,4 3,975 3,925-1,3 SYSXT2000i 2012,3 3,730 3,655-2,0 SYSXT2000i 2012,2 4,085 4,050-0,9 SYSXT2000i 2012,1 4,128 4,110-0,4 SYSXT2000i 2011,4 3,925 4,050 3,2 SYSXT2000i 2011,3 3,635 3,615-0,6 SYSXT2000i 2011,2 3,780 3,735-1,2 SYSXT2000i 2011,1 4,515 4,430-1,9 SYSXT2000i 2010,4 3,725 3,630-2,6 SYSXT2000i 2010,3 4,325 4,245-1,9 SYSXT2000i ABX Micros CRP 200, Advia 60 4,660 0,1037 2,2 6 0 ABX Pentra 80/XL80/DX120 4,515 0,0860 1,9 10 0 Advia 120, 2120/2120i 4,655 0,0579 1,2 19 0 Cell-Dyn Sapphire 4,660 0,0798 1,7 19 0 Cell-Dyn 3200, Ruby 4,620 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 4,585 0,0703 1,5 5 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 4,598 0,0433 0,9 54 0 UniCel DxH 800 4,660 2 0 Alle EPK 4,610 0,0767 1,7 118 0 E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

B-Hb, g/dl Sysmex XT-2000i [Sysmex] Eget snitt: 14,70(14,8-14,6) Avvik fra tillagt verdi: 1,4% - Akseptomr (tillagt verdi ± 5%): 13,78-15,23 Alle Hb 2014,2 14,50 14,70 1,4 SYSXT2000i 2014,1 11,10 11,35 2,3 SYSXT2000i 2013,4 13,40 13,65 1,9 SYSXT2000i 2013,3 11,05 11,30 2,3 SYSXT2000i 2013,2 10,90 10,95 0,5 SYSXT2000i 2013,1 12,05 12,00-0,4 SYSXT2000i 2012,4 12,10 12,20 0,8 SYSXT2000i 2012,3 11,20 11,30 0,9 SYSXT2000i 2012,2 12,65 12,70 0,4 SYSXT2000i 2012,1 11,65 11,60-0,4 SYSXT2000i 2011,4 12,35 12,65 2,4 SYSXT2000i 2011,3 10,85 11,05 1,8 SYSXT2000i 2011,2 11,45 11,80 3,1 SYSXT2000i 2011,1 13,25 13,60 2,6 SYSXT2000i 2010,4 11,00 11,25 2,3 SYSXT2000i 2010,3 12,78 12,70-0,6 SYSXT2000i ABX Micros CRP 200, Advia 60 14,25 0,123 0,9 6 0 ABX Pentra 80/XL80/DX120 14,33 0,195 1,4 10 0 Advia 120, 2120/2120i 14,65 0,235 1,6 19 0 Cell-Dyn Sapphire 14,55 0,228 1,6 19 0 Cell-Dyn 3200, Ruby 14,45 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 14,30 0,094 0,7 5 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 14,50 0,155 1,1 54 0 UniCel DxH 800 14,40 2 0 Alle Hb 14,50 0,221 1,5 118 0 B-EVF, volumfraksjon Sysmex XT-2000i [Sysmex] Eget snitt: 0,410(0,41-0,41) Avvik fra tillagt verdi: -2,4% - Akseptomr (tillagt verdi ± 10%): 0,378-0,462 Alle EVF 2014,2 0,420 0,410-2,4 SYSXT2000i 2014,1 0,335 0,330-1,5 SYSXT2000i 2013,4 0,400 0,390-2,5 SYSXT2000i 2013,3 0,343 0,340-0,9 SYSXT2000i 2013,2 0,340 0,325-4,4 SYSXT2000i 2013,1 0,355 0,350-1,4 SYSXT2000i 2012,4 0,380 0,375-1,3 SYSXT2000i 2012,3 0,340 0,330-2,9 SYSXT2000i 2012,2 0,380 0,370-2,6 SYSXT2000i 2012,1 0,360 0,350-2,8 SYSXT2000i 2011,4 0,360 0,370 2,8 SYSXT2000i 2011,3 0,335 0,335 0,0 SYSXT2000i 2011,2 0,360 0,360 0,0 SYSXT2000i 2011,1 0,390 0,390 0,0 SYSXT2000i 2010,4 0,340 0,330-2,9 SYSXT2000i 2010,3 0,388 0,380-2,1 SYSXT2000i ABX Micros CRP 200, Advia 60 0,433 0,0144 3,3 6 0 ABX Pentra 80/XL80/DX120 0,435 0,0084 1,9 10 0 Advia 120, 2120/2120i 0,435 0,0116 2,7 19 0 Cell-Dyn Sapphire 0,430 0,0096 2,2 19 0 Cell-Dyn 3200, Ruby 0,420 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 0,410 0,0104 2,5 5 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 0,420 0,0087 2,1 54 0 UniCel DxH 800 0,443 2 0 Alle EVF 0,425 0,0124 2,9 118 0 E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

E-MCV, fl Sysmex XT-2000i [Sysmex] Eget snitt: 88,50(88,6-88,4) Avvik fra tillagt verdi: -3,0% - Akseptomr (tillagt verdi ± 10%): 82,13-100,38 Alle MCV 2014,2 91,25 88,50-3,0 SYSXT2000i 2014,1 94,05 92,75-1,4 SYSXT2000i 2013,4 92,50 92,00-0,5 SYSXT2000i 2013,3 95,40 94,60-0,8 SYSXT2000i 2013,2 95,93 95,55-0,4 SYSXT2000i 2013,1 85,50 85,05-0,5 SYSXT2000i 2012,4 94,85 95,15 0,3 SYSXT2000i 2012,3 90,75 89,15-1,8 SYSXT2000i 2012,2 93,25 91,60-1,8 SYSXT2000i 2012,1 87,30 85,90-1,6 SYSXT2000i 2011,4 91,70 92,00 0,3 SYSXT2000i 2011,3 92,05 92,35 0,3 SYSXT2000i 2011,2 94,90 95,70 0,8 SYSXT2000i 2011,1 86,55 87,50 1,1 SYSXT2000i 2010,4 90,30 92,05 1,9 SYSXT2000i 2010,3 89,35 89,20-0,2 SYSXT2000i ABX Micros CRP 200, Advia 60 93,00 2,478 2,7 6 0 ABX Pentra 80/XL80/DX120 95,50 1,220 1,3 10 0 Advia 120, 2120/2120i 93,50 1,974 2,1 19 0 Cell-Dyn Sapphire 91,80 1,206 1,3 19 0 Cell-Dyn 3200, Ruby 90,25 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 89,60 0,909 1,0 5 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 91,25 1,483 1,6 54 0 UniCel DxH 800 95,13 2 0 Alle MCV 91,95 2,140 2,3 118 0 E-MCH, pg Sysmex XT-2000i [Sysmex] Eget snitt: 32,10(32,3-31,9) Avvik fra tillagt verdi: 1,9% - Akseptomr (tillagt verdi ± 10%): 28,35-34,65 Alle MCH 2014,2 31,50 32,10 1,9 SYSXT2000i 2014,1 31,10 31,75 2,1 SYSXT2000i 2013,4 31,20 32,25 3,4 SYSXT2000i 2013,3 30,80 31,15 1,1 SYSXT2000i 2013,2 31,25 32,20 3,0 SYSXT2000i 2013,1 29,00 29,15 0,5 SYSXT2000i 2012,4 30,45 31,10 2,1 SYSXT2000i 2012,3 29,90 30,95 3,5 SYSXT2000i 2012,2 30,90 31,35 1,5 SYSXT2000i 2012,1 28,20 28,20 0,0 SYSXT2000i 2011,4 31,35 31,25-0,3 SYSXT2000i 2011,3 29,80 30,55 2,5 SYSXT2000i 2011,2 30,25 31,75 5,0 SYSXT2000i 2011,1 29,20 30,70 5,1 SYSXT2000i 2010,4 29,50 30,95 4,9 SYSXT2000i 2010,3 29,55 29,95 1,4 SYSXT2000i ABX Micros CRP 200, Advia 60 30,68 0,814 2,7 6 0 ABX Pentra 80/XL80/DX120 31,53 0,477 1,5 10 0 Advia 120, 2120/2120i 31,45 0,585 1,9 17 1 Cell-Dyn Sapphire 31,30 0,608 1,9 19 0 Cell-Dyn 3200, Ruby 31,60 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 31,25 0,487 1,6 5 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 31,50 0,442 1,4 54 0 UniCel DxH 800 30,95 2 0 Alle MCH 31,45 0,545 1,7 116 1 E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

E-MCHC, g/dl Sysmex XT-2000i [Sysmex] Eget snitt: 36,25(36,5-36,0) Avvik fra tillagt verdi: 5,1% - Akseptomr (tillagt verdi ± 10%): 31,03-37,93 Alle MCHC 2014,2 34,48 36,25 5,1 SYSXT2000i 2014,1 33,00 34,20 3,6 SYSXT2000i 2013,4 33,68 35,05 4,1 SYSXT2000i 2013,3 32,30 32,90 1,9 SYSXT2000i 2013,2 32,53 33,70 3,6 SYSXT2000i 2013,1 34,05 34,30 0,7 SYSXT2000i 2012,4 32,05 32,65 1,9 SYSXT2000i 2012,3 32,88 34,70 5,5 SYSXT2000i 2012,2 33,20 34,20 3,0 SYSXT2000i 2012,1 32,25 32,90 2,0 SYSXT2000i 2011,4 34,20 33,95-0,7 SYSXT2000i 2011,3 32,45 33,05 1,8 SYSXT2000i 2011,2 31,95 33,00 3,3 SYSXT2000i 2011,1 33,78 35,10 3,9 SYSXT2000i 2010,4 32,80 33,65 2,6 SYSXT2000i 2010,3 33,03 33,55 1,6 SYSXT2000i ABX Micros CRP 200, Advia 60 33,13 1,149 3,5 6 0 ABX Pentra 80/XL80/DX120 33,05 0,345 1,0 10 0 Advia 120, 2120/2120i 33,43 0,939 2,8 18 0 Cell-Dyn Sapphire 34,00 0,690 2,0 19 0 Cell-Dyn 3200, Ruby 34,50 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 34,70 0,728 2,1 5 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 34,48 0,728 2,1 54 0 UniCel DxH 800 32,55 2 0 Alle MCHC 34,10 0,938 2,8 117 0 B-Trombocytter, 10 9 /L Sysmex XT-2000i [Sysmex] Eget snitt: 146,0(146-146) Avvik fra tillagt verdi: 0,8% - Akseptomr (tillagt verdi ± 20%): 115,8-173,8 Alle TPK 2014,2 144,8 146,0 0,8 SYSXT2000i 2014,1 242,0 243,0 0,4 SYSXT2000i 2013,4 195,5 190,5-2,6 SYSXT2000i 2013,3 159,5 161,5 1,3 SYSXT2000i 2013,2 201,0 207,5 3,2 SYSXT2000i 2013,1 135,5 149,5 10,3 SYSXT2000i 2012,4 222,0 225,5 1,6 SYSXT2000i 2012,3 136,5 132,0-3,3 SYSXT2000i 2012,2 204,5 219,5 7,3 SYSXT2000i 2012,1 229,0 226,5-1,1 SYSXT2000i 2011,4 151,5 166,0 9,6 SYSXT2000i 2011,3 227,5 237,0 4,2 SYSXT2000i 2011,2 238,5 252,5 5,9 SYSXT2000i 2011,1 167,5 196,5 17,3 SYSXT2000i 2010,4 274,8 322,5 17,4 SYSXT2000i 2010,3 160,0 174,0 8,8 SYSXT2000i ABX Micros CRP 200, Advia 60 146,5 9,67 6,6 6 0 ABX Pentra 80/XL80/DX120 150,0 4,93 3,3 10 0 Advia 120, 2120/2120i 149,5 5,65 3,8 19 0 Cell-Dyn Sapphire 154,0 7,21 4,7 19 0 Cell-Dyn 3200, Ruby 175,5 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 145,0 5,91 4,1 5 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 144,8 6,29 4,4 52 1 UniCel DxH 800 145,0 2 0 Alle TPK 148,3 7,94 5,4 116 1 E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

Pasient Middel-MCV, fl Sysmex XT-2000i [Sysmex] Eget snitt: 94,1(94,1- ) Avvik fra tillagt verdi: 3,1% - Akseptomr (tillagt verdi ± 10%): 82,2-100,4 Alle PM-MCV 2014,2 91,3 94,1 3,1 SYSXT2000i 2014,1 91,0 92,4 1,5 SYSXT2000i 2013,4 91,1 93,3 2,4 SYSXT2000i 2013,3 91,6 92,8 1,3 SYSXT2000i 2013,2 91,6 94,4 3,1 SYSXT2000i 2013,1 91,0 92,4 1,5 SYSXT2000i 2012,4 91,0 94,1 3,4 SYSXT2000i 2012,3 91,3 94,3 3,3 SYSXT2000i 2012,2 91,1 92,6 1,6 SYSXT2000i 2012,1 91,0 91,9 1,0 SYSXT2000i 2011,4 90,7 94,1 3,7 SYSXT2000i 2011,3 90,6 95,2 5,1 SYSXT2000i 2011,2 90,8 94,8 4,4 SYSXT2000i 2011,1 90,7 94,5 4,2 SYSXT2000i 2010,4 90,6 95,0 4,9 SYSXT2000i 2010,3 90,4 92,9 2,8 SYSXT2000i ABX Micros CRP 200, Advia 60 89,9 1 0 ABX Pentra 80/XL80/DX120 93,4 1,95 2,1 7 0 Advia 120, 2120/2120i 91,7 1,35 1,5 18 0 Cell-Dyn Sapphire 91,7 1,30 1,4 18 1 Cell-Dyn 3200, Ruby 90,6 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 90,7 1 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 91,3 1,48 1,6 51 1 UniCel DxH 800 92,5 2 0 Pasientmiddel MCV skal ligge innenfor 89,5±3 fl dersom en analyserer prøver fra en generell pasientpopulasjon Dersom det i hovedsak analyseres prøver fra barn (2 mnd-14 år), kan lavere pasientmiddel MCV forventes Dersom dere har en stor andel tilsendte prøver (eldre enn 24t), vil høyere pasientmiddel MCV forventes Tilsendte prøver vil også gi lavere MCHC enn normalt, mens MCH ikke vil påvirkes i særlig grad Ved analysering av generell pasientpopulasjon og pasientmiddel MCV ligger utenfor 89,5±3 fl, bør parameteren vurderes Alle PM-MCV 91,5 1,47 1,6 101 2 Pasient Middel-MCH, pg Sysmex XT-2000i [Sysmex] Eget snitt: 31,1(31,1- ) Avvik fra tillagt verdi: 3,0% - Akseptomr (tillagt verdi ± 10%): 27,2-33,2 Alle PM-MCH 2014,2 30,2 31,1 3,0 SYSXT2000i 2014,1 30,1 31,5 4,7 SYSXT2000i 2013,4 30,2 31,0 2,6 SYSXT2000i 2013,3 30,1 30,9 2,7 SYSXT2000i 2013,2 30,1 30,9 2,7 SYSXT2000i 2013,1 30,1 30,0-0,3 SYSXT2000i 2012,4 30,0 30,5 1,7 SYSXT2000i 2012,3 30,1 30,8 2,3 SYSXT2000i 2012,2 30,1 30,6 1,7 SYSXT2000i 2012,1 30,1 30,4 1,0 SYSXT2000i 2011,4 30,2 29,6-2,0 SYSXT2000i 2011,3 30,2 30,6 1,3 SYSXT2000i 2011,2 30,1 31,1 3,3 SYSXT2000i 2011,1 30,0 31,4 4,7 SYSXT2000i 2010,4 30,0 31,3 4,3 SYSXT2000i 2010,3 30,0 30,5 1,7 SYSXT2000i ABX Micros CRP 200, Advia 60 30,0 1 0 ABX Pentra 80/XL80/DX120 30,8 0,39 1,3 7 0 Advia 120, 2120/2120i 30,5 0,38 1,3 18 0 Cell-Dyn Sapphire 30,6 0,68 2,2 19 0 Cell-Dyn 3200, Ruby 30,3 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 29,8 1 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 30,2 0,39 1,3 52 0 UniCel DxH 800 30,6 2 0 Alle PM-MCH 30,3 0,48 1,6 103 0 E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

Pasient Middel-MCHC, g/dl Sysmex XT-2000i [Sysmex] Eget snitt: 33,2(33,2- ) Avvik fra tillagt verdi: 0,3% - Akseptomr (tillagt verdi ± 10%): 29,8-36,4 Alle PM-MCHC 2014,2 33,1 33,2 0,3 SYSXT2000i 2014,1 33,0 33,9 2,7 SYSXT2000i 2013,4 33,1 33,2 0,3 SYSXT2000i 2013,3 33,0 33,0 0,0 SYSXT2000i 2013,2 33,0 32,8-0,6 SYSXT2000i 2013,1 33,0 32,5-1,5 SYSXT2000i 2012,4 32,9 32,4-1,5 SYSXT2000i 2012,3 32,8 32,5-0,9 SYSXT2000i 2012,2 33,0 33,1 0,3 SYSXT2000i 2012,1 33,1 33,2 0,3 SYSXT2000i 2011,4 33,3 31,6-5,1 SYSXT2000i 2011,3 33,1 32,2-2,7 SYSXT2000i 2011,2 33,0 32,8-0,6 SYSXT2000i 2011,1 33,0 33,2 0,6 SYSXT2000i 2010,4 33,1 33,0-0,3 SYSXT2000i 2010,3 33,0 32,9-0,3 SYSXT2000i ABX Micros CRP 200, Advia 60 33,4 1 0 ABX Pentra 80/XL80/DX120 33,0 0,65 2,0 7 0 Advia 120, 2120/2120i 33,1 0,65 2,0 18 0 Cell-Dyn Sapphire 33,5 0,57 1,7 18 1 Cell-Dyn 3200, Ruby 33,7 3 0 Sysmex K-4500, KX -21, KX- 21N, Poch-100i, XP-300 32,9 1 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 33,1 0,44 1,3 52 0 UniCel DxH 800 33,1 2 0 Alle PM-MCHC 33,1 0,53 1,6 102 1 B-Neut, % Sysmex XT-2000i [Sysmex] 2014,2 59,35 60,30 1,6 SYSXT2000i 2014,1 51,75 52,55 1,5 SYSXT2000i 2013,4 68,05 68,45 0,6 SYSXT2000i 2013,3 62,95 63,60 1,0 SYSXT2000i 2013,2 61,55 61,90 0,6 SYSXT2000i 2013,1 48,38 47,40-2,0 SYSXT2000i 2012,4 48,00 47,65-0,7 SYSXT2000i 2012,3 66,58 67,05 0,7 SYSXT2000i 2012,2 61,65 62,35 1,1 SYSXT2000i 2012,1 54,95 54,15-1,5 SYSXT2000i Eget snitt: 60,30(59,8-60,8) Avvik fra tillagt verdi: 1,6% - Akseptomr (tillagt verdi ± 15%): 50,45-68,25 Alle 5-part Neut ABX Pentra 80/XL80/DX120 56,83 1,584 2,8 8 0 Advia 120, 2120/2120i 62,30 1,481 2,4 19 0 Cell-Dyn Sapphire 59,15 1,677 2,8 19 0 Cell-Dyn 3200, Ruby 53,75 3 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 59,35 0,747 1,3 50 1 UniCel DxH 800 58,88 2 0 Alle 5-part Neut 59,40 2,226 3,8 101 1 E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

B-Lymf, % Sysmex XT-2000i [Sysmex] 2014,2 24,75 23,85-3,6 SYSXT2000i 2014,1 31,93 31,35-1,8 SYSXT2000i 2013,4 22,80 22,70-0,4 SYSXT2000i 2013,3 28,75 28,40-1,2 SYSXT2000i 2013,2 28,35 28,05-1,1 SYSXT2000i 2013,1 36,63 37,20 1,6 SYSXT2000i 2012,4 31,10 31,55 1,4 SYSXT2000i 2012,3 23,20 22,70-2,2 SYSXT2000i 2012,2 27,30 26,75-2,0 SYSXT2000i 2012,1 27,80 27,35-1,6 SYSXT2000i Eget snitt: 23,85(24,1-23,6) Avvik fra tillagt verdi: -3,6% - Akseptomr (tillagt verdi ± 15%): 21,04-28,46 Alle 5-part Lymf ABX Pentra 80/XL80/DX120 27,70 1,334 4,8 8 0 Advia 120, 2120/2120i 22,35 0,723 3,2 19 0 Cell-Dyn Sapphire 26,55 1,078 4,1 19 0 Cell-Dyn 3200, Ruby 32,70 3 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 24,75 0,698 2,8 51 0 UniCel DxH 800 25,50 2 0 Alle 5-part Lymf 24,88 2,092 8,4 102 0 B-Mono, % Sysmex XT-2000i [Sysmex] 2014,2 7,83 8,10 3,4 SYSXT2000i 2014,1 11,70 11,60-0,9 SYSXT2000i 2013,4 7,70 7,65-0,6 SYSXT2000i 2013,3 5,53 5,30-4,2 SYSXT2000i 2013,2 6,05 6,10 0,8 SYSXT2000i 2013,1 10,80 10,95 1,4 SYSXT2000i 2012,4 13,05 12,90-1,1 SYSXT2000i 2012,3 8,10 7,80-3,7 SYSXT2000i 2012,2 8,85 8,75-1,1 SYSXT2000i 2012,1 11,30 12,40 9,7 SYSXT2000i Eget snitt: 8,10(8,7-7,5) Avvik fra tillagt verdi: 3,4% - Akseptomr (tillagt verdi ± 30%): 5,48-10,18 Alle 5-part Mono ABX Pentra 80/XL80/DX120 7,90 1,092 13,8 8 0 Advia 120, 2120/2120i 5,90 0,580 9,8 19 0 Cell-Dyn Sapphire 7,15 0,678 9,5 19 0 Cell-Dyn 3200, Ruby 6,60 3 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 7,83 0,405 5,2 50 1 UniCel DxH 800 7,38 2 0 Alle 5-part Mono 7,50 1,056 14,1 101 1 E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737

B-Eos, % Sysmex XT-2000i [Sysmex] 2014,2 6,80 6,80 0,0 SYSXT2000i 2014,1 3,85 4,15 7,8 SYSXT2000i 2013,4 1,05 1,05 0,0 SYSXT2000i 2013,3 1,75 1,85 5,7 SYSXT2000i 2013,2 3,35 3,35 0,0 SYSXT2000i 2013,1 3,65 3,95 8,2 SYSXT2000i 2012,4 6,90 7,10 2,9 SYSXT2000i 2012,3 1,50 1,70 13,3 SYSXT2000i 2012,2 2,00 2,05 2,5 SYSXT2000i 2012,1 5,48 5,60 2,2 SYSXT2000i Eget snitt: 6,80(6,5-7,1) Avvik fra tillagt verdi: 0,0% - Akseptomr (tillagt verdi ± 50%): 3,40-10,20 Alle 5-part Eos ABX Pentra 80/XL80/DX120 5,85 0,769 13,2 8 0 Advia 120, 2120/2120i 6,50 0,968 14,9 19 0 Cell-Dyn Sapphire 5,85 1,060 18,1 19 0 Cell-Dyn 3200, Ruby 6,60 3 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 6,80 0,302 4,4 51 0 UniCel DxH 800 7,00 2 0 Alle 5-part Eos 6,60 0,832 12,6 102 0 B-Baso, % Sysmex XT-2000i [Sysmex] 2014,2 1,35 0,95-29,6 SYSXT2000i 2014,1 0,40 0,35-12,5 SYSXT2000i 2013,4 0,30 0,15-50,0 SYSXT2000i 2013,3 0,78 0,85 9,0 SYSXT2000i 2013,2 0,65 0,60-7,7 SYSXT2000i 2013,1 0,50 0,50 0,0 SYSXT2000i 2012,4 0,80 0,80 0,0 SYSXT2000i 2012,3 0,70 0,75 7,1 SYSXT2000i 2012,2 0,20 0,10-50,0 SYSXT2000i 2012,1 0,55 0,50-9,1 SYSXT2000i Eget snitt: 0,95(0,9-1,0) Avvik fra tillagt verdi: -29,6% - Akseptomr (tillagt verdi ± 200%): 0,00-4,05 Alle 5-part Baso ABX Pentra 80/XL80/DX120 1,33 0,697 52,4 8 0 Advia 120, 2120/2120i 0,80 0,205 25,6 19 0 Cell-Dyn Sapphire 1,15 0,323 28,1 17 2 Cell-Dyn 3200, Ruby 2,65 3 0 Sysmex XE-2100/5000, XT-2000i/1800i, XS-1000i, XN-1000 1,35 0,174 12,9 49 2 UniCel DxH 800 1,30 2 0 Alle 5-part Baso 1,20 0,422 35,2 98 4 E-post: noklus@noklusno wwwnoklusno 5009 Bergen Orgnr 984 027 737