Procedure for use of the Vaki Smolt Counter for Well boats



Like dokumenter
Start Here USB *CC * *CC * USB USB

Elektronisk termostat med spareprogram. Lysende LCD display øverst på ovnen for enkel betjening.

Institutt for biovitenskap

Hvordan føre reiseregninger i Unit4 Business World Forfatter:

Norsk (English below): Guide til anbefalt måte å printe gjennom plotter (Akropolis)

Trådløsnett med Windows Vista. Wireless network with Windows Vista

Trådløsnett med Windows XP. Wireless network with Windows XP

Justeringsanvisninger finnes på de to siste sidene.

REMOVE CONTENTS FROM BOX. VERIFY ALL PARTS ARE PRESENT READ INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION

PSi Apollo. Technical Presentation

Trådløsnett med. Wireless network. MacOSX 10.5 Leopard. with MacOSX 10.5 Leopard

Elektronisk innlevering/electronic solution for submission:

EMPIC MEDICAL. Etterutdanningskurs flyleger 21. april Lars (Lasse) Holm Prosjektleder Telefon: E-post:

Slope-Intercept Formula

SmartPass Mini User Manual BBNORGE.NO

Vedlegg 2 Dokumentasjon fra TVM leverandør

Exercise 1: Phase Splitter DC Operation

Unit Relational Algebra 1 1. Relational Algebra 1. Unit 3.3

Forord The Smolt Fish Counters

Trigonometric Substitution

GLOBALCOMSERVER HP 9100C DIGITAL SENDER GATEWAY ADMINISTRATOR S GUIDE 1998 AVM INFORMATIQUE (UPDATED: AUGUST 22, 2006)

Bestille trykk av doktoravhandling Ordering printing of PhD Thesis

Compello Fakturagodkjenning Versjon 10 Software as a service. Tilgang til ny modulen Regnskapsføring

Windlass Control Panel

Information search for the research protocol in IIC/IID

Compello Fakturagodkjenning Versjon 10.5 As a Service. Tilgang til Compello Desktop - Regnskapsføring og Dokument import

SERVICE BULLETINE

HONSEL process monitoring

Moving Objects. We need to move our objects in 3D space.

User Guide

Du må håndtere disse hendelsene ved å implementere funksjonene init(), changeh(), changev() og escape(), som beskrevet nedenfor.

Perpetuum (im)mobile

- Vennlig hilsen gründerne bak retyre

Trådløst nett UiT Feilsøking. Wireless network UiT Problem solving

SafeRing / SafePlus Retrofit of under voltage coil V Module

Mathematics 114Q Integration Practice Problems SOLUTIONS. = 1 8 (x2 +5x) 8 + C. [u = x 2 +5x] = 1 11 (3 x)11 + C. [u =3 x] = 2 (7x + 9)3/2

Windows Server 2008 Hyper-V, Windows Server 2008 Server Core Installation Notes

TB-615 / TB-617 Wireless slim keyboard. EN User guide SE Användarhandledning FI Käyttöohje DK Brugervejledning NO Bruksanvisning

Endelig ikke-røyker for Kvinner! (Norwegian Edition)

5 E Lesson: Solving Monohybrid Punnett Squares with Coding

INSTALLATION GUIDE FTR Cargo Rack Regular Ford Transit 130" Wheelbase ( Aluminum )

Dynamic Programming Longest Common Subsequence. Class 27

manual Movie digitizer Moviesaver 300 Item: Plexgear

MID-TERM EXAM TDT4258 MICROCONTROLLER SYSTEM DESIGN. Wednesday 3 th Mars Time:


The regulation requires that everyone at NTNU shall have fire drills and fire prevention courses.

INSTALLATION GUIDE FTR Cargo Rack Regular Ford Transit 130" Wheelbase ( Aluminum )

Radix en enkel innføring

Trådløst nett UiT. Feilsøking. Wireless network UiT Problem solving

Rom-Linker Software User s Manual

KROPPEN LEDER STRØM. Sett en finger på hvert av kontaktpunktene på modellen. Da får du et lydsignal.

SAS FANS NYTT & NYTTIG FRA VERKTØYKASSA TIL SAS 4. MARS 2014, MIKKEL SØRHEIM

Start MATLAB. Start NUnet Applications Statistical and Computational packages MATLAB Release 13 MATLAB 6.5

6105 Windows Server og datanett

FYSMEK1110 Eksamensverksted 23. Mai :15-18:00 Oppgave 1 (maks. 45 minutt)

KAMPANJE AZG : Skifte bolter reimhjul

Brukerveiledning. Rolltalk PowerArm. Rev A NO

Den som gjør godt, er av Gud (Multilingual Edition)

Viktig informasjon om omlegging til Windows 10

UNIVERSITETET I OSLO

Innhold. Instruks for melding av hærverk. ID1743-a- hærverk. IE76286-b- Trafikkdetektor Leggebeskrivelse E og E

UNIVERSITY OF OSLO DEPARTMENT OF ECONOMICS

SafeRing / SafePlus Retrofit of auxiliary switch S9 for relay trip indication V module

Profile handbook. for

Midnight BBQ Light USER MANUAL

Brukerveiledning SafeUse. English version: slide 15

Neural Network. Sensors Sorter

SafeRing / SafePlus Retrofit of auxiliary switch S9 for fuse blown indication F module

Newtons fargeskive. Regnbuens farger blir til hvitt. Sett skiva i rask rotasjon ved hjelp av sveiva.

Oppgave 1a Definer følgende begreper: Nøkkel, supernøkkel og funksjonell avhengighet.

Micro/Macro Fiske teller Bruker Manual

[36] Boiserie. Melamine and lacquered door handles. Optional metal handle. Standard ABS handle. Look _silver (J) Pop _silver (P) _chromed (K)

Brukerinstruks / User Manual

UNIVERSITETET I OSLO

Eiendomsverdi. The housing market Update September 2013

User manual English Svenska Norsk

Kontrollert strømutkobling Prosedyre

Appendix B, not for publication, with screenshots for Fairness and family background

KAMPANJE APK : APK-8: Bytte bakaksel bolter

BRUKERVEILEDNING FOR MC50.

Public roadmap for information management, governance and exchange SINTEF

KAMPANJE APK : APK-4: Kontroll montering EGT-2

Databases 1. Extended Relational Algebra

Printer Driver. Denne veiledningen beskriver installasjonen av skriverdriveren for Windows Vista. Før denne programvaren brukes

Endringer i neste revisjon av EHF / Changes in the next revision of EHF 1. October 2015

KAMPANJE APK : APK-5: Skifte pakninger mellom turbo og CCDPF

EMS 1. Music Streamer. Owner's Manual

NORWEGIAN DESIGN SINCE Art.no: Jan Connect. Adjust. Save. WI-FI BRUKSANVISNING WI-FI USER GUIDE ANDROID

AquaScan Win 2.5 manual

manual Plexgear L14 Item: Plexgear

SQL Server guide til e-lector

Monteringsprosedyre for Soundstop - lydmatte

SHORE POWER CONVERTER LIST 2018

1. Opprette Workspace: Velg File, New Workspace. Angi Workspace name og location (hvor filene skal lagres). Trykk OK

Han Ola of Han Per: A Norwegian-American Comic Strip/En Norsk-amerikansk tegneserie (Skrifter. Serie B, LXIX)

UNIVERSITETET I OSLO ØKONOMISK INSTITUTT

Time & Attendance Timeregistrering. End User Sluttbruker

INF Logikk og analysemetoder Forslag til løsning på oppgave fra læreboken

MONTASJEBESKRIVELSE INSTALLATION GUIDE

Transkript:

Procedure for use of the Vaki Smolt Counter for Well boats This document is a recommended procedure for the operation of a Vaki smolt counter on well boats in combination with a vacuum pump. This document should be used in conjunction with the Macro user manual. Action 1. Turn on the counter 2-4 hours before use. 2. Once the counter is warm open the lower hatch to inspect the mirrors and lens cover glass. Remove any water drops, residue or dirt with a soft cloth. 3. Unlatch the transport locks, turn on the hydraulic system and turn the hydraulic control to Auto mode. Explanation The power switch is usually located on a control panel close to the counter on the deck. When the counter is powered on the back light and the heaters will turn on and remove condensation and humidity from the mirrors and glass. Water drops and marks on the mirrors and glass can interfere with the counting. The dewaterer and counter will self adjust into the defined horizontal position. To redefine the horizontal position: 1. Turn the hydraulic control to Manual mode and using the manual handles reposition the counting unit. 2. In the desired position push the green button for at least 3 seconds to store the new position. 3. Turn the control back to Auto mode. 4. Turn on the computer in the wheel house. The Vaki counting program will start automatically. 5. In the main screen select the Visibility function on the touch screen. If a red bar and the text not counting appears in the lower left corner proceed to step 5, otherwise continue in step 7 A curve like the one shown in the picture below will display. It should have a shape and values similar to those indicated in the picture. The red cure should be some where between 160 and 220 (y-axes). Vaki Aquaculture Systems 1

6. Calibrate the counter by pushing the Calibrate button in the main screen. 7. In the main screen tap the New counting session tab on the touch screen. To start and define a new count. Give the counting session an appropriate name and add comments in the pop up window. 8. Check the recording mode in the lower left corner of the screen. It should say Counting: Recording 9. Check that the counter now is ready for counting. The horizontal axes (x-axes) should start around 200 and end at approximately 1860. This can vary slightly from one installation to an other. Do not run water or fish thru the counter during this procedure. Ragged or un-even curve indicates that either the mirrors or glass are dirty or there may be problems with the configuration. Clean the mirrors and glass and try again. This should only be done if the previous steps have been completed successfully and it is not necessary to calibrate the counter for every counting session. The calibration will run through some checks and verify the level of light and set the width of the counter. After a calibration one should check the visibility curve. The width should always be approximately 200 for the left value to 1800 for the right value. Here the identifying name of the counting session is given and comments added. This information is used in the filenames and displayed in the printed counting report. If the mode is not correct enter the Settings function and set to continuous recording. This is necessary to obtain a video recording of the complete counting session. The counter should now indicate that it is ready for counting by displaying a green bar at the bottom of the screen and a number 0 both in the counter field and the Total field. 10. Pump fish over the dewaterer and into the counter in an even It is possible that excessive turbulent water in the counter can create shadows that may be counted or can create problems with the image analysis. Vaki Aquaculture Systems 2

continuous flow. Check the thru put graph ensuring the thru put line remains under the red maximum line. Ensure that white water from the vacuum pump does not enter the counter channel. 11. To store sub total in a counting session (e.g. when counting into a number of different cages) push store button on the touch screen. 12. The number in the counting field can then be reset to 0 by double tapping the displayed number on the touch screen. 13. It is possible to pause the counting session e.g. to clean mirrors by pushing the stop button. Remember to push the start button before continuing to pump fish through the counter. Over loading the counter can result in undercounting. The number in the counting field will be stored and displayed with the time stamp on the count report. This must be confirmed by an OK. The counting field will be zeroed; the total in the bottom of the screen will remain unchanged. This can be useful when counting a predefined batch number into a cage. When the counting session has been stopped with the stop button no images will be recorded or counted. 14. End the counting session by pushing the Store button and then End counting 15. View the count report and recording by tapping the Report or Record functions. 16. Save the report and image recording to a USB memory stick by copying the * This will store the last intermediate count into the stored values and end the session. It is recommended to end the session before the last blows are taken by the vacuum system. This to avoid big water splashes in the recording. At this point there should not be any fish left in the system. The counting report and recorded images from all saved counting sessions can be reviewed. A hard copy of the report can be printed if a printer is connected to the counter computer. NOTE: the corresponding (*.blb and *.mse files) must be stored in the same folder together. The files should be burned to a CD Vaki Aquaculture Systems 3

.mse and *.blb files stored in the folder C:/Reports/ on the counter computer. ROM for archive. For downloading RemoteC see: http://www.vaki.is/vaki/products/micromacrocounter/softwareupgrades/ Vaki Aquaculture Systems 4

Vaki Aquaculture Systems 5

Prosedyre for bruk av Vaki teller for brønnbåt Følgende prosedyre er en anbefalt fremgangsmåte som vil sikre gode resultater ved smolt telling på brønnbåter. Operasjon Forklaring 1. Slå på teller 2 4 timer før telling Strøm kobles til, vanligvis ved å slå på bryter i el-skap. Speil og glass varmes nå opp slik at de blir duggfrie 2. Etter at teller er blitt varm åpnes nedre luke for inspeksjon av glass og to speil. Evt dråper og utfellinger må tørkes bort. 3. Ta teller ut av transportsikringer, slå på hydraulikkaggregat og sett hydraulikk funksjon til auto. 4. PC slås på og telle-program startes. 5. Visibility funksjon i program velges (egen trykk-knapp i hovedskjermbilde) 6. Still inn telleren ved å trykke på Kallibrering knappen i hovedskjermbildet 7. Definer og start Ny telling med egen trykk-knapp i hovedskjembilde og gi tellingen et egnet navn.. Rene speil og glass foran linse gir bedre kvalitet på telling. Ved å gjøre dette vil avsilingskasse og teller stille seg inn i tidligere definert vater posisjon. Hvis en ønsker å redefinere vater kan man slå hydraulikk operasjonen over til manuell kjøring og med hjelp av ventiler (spaker) kan ønsket helning på teller stilles inn. Trykk inn den grønne knappen i 3 sekund og den nye innstillingen er lagret i minnet. Slå tilbake til auto Hvis rödt felt vises på skjermen og teksten not counting kommer frem i nedre venstre hjörne gå til skritt 5, ellers gå rett til skritt 7. Den røde kurven skal vise en verdi mellom 160 (starter på 120 på bildet!) og 220 (y-aksen) og ha form som angitt i bilde nederst i denne prosedyren. Kurven skal starte på ca 200 og slutte på ca. 1860 (x-aksen) Telleren skal ikke kjøres med vann/fisk når denne testen gjennomføres! Taggete eller dårlig kurve kan tyde på skitne speil/glass eller problemer med innstillinger. Rens og prøv igjen. Kalibrering skal kunn utföres om tidligere skritt er gjennomfört. Det er ikke nödvendig å kalibrere telleren för hver telling. Kalibreringen will utföre noen sjekker på maskinen og instillinger, bla lysstyrke og bredde på tellefeltet. Eftef kalibrering bör en pröve visibility og kontrollere at bredden ligger et sted mellom 200 og 1800 i venstre og högre verdi. Her skrives inn kjennetegn på selve tellingen samt kommentarer. Opplysningene som legges inn her vil legge seg i filnavnet og også stå på tellerapporten. Vaki Aquaculture Systems 6

8. Sjekk innstillinger Sjekk at telleren er stilt til kontinuerlig opptak 9. Telleren skal nå være klar for telling og ha grønt felt nederst på skjermen og et tall som viser 0 både i tellefelt og i Totalen 10. Pump fisk over telleren i jevnest mulig flyt slik at antall fisk per minutt ligger under den røde kurven vist (se vedlagt bilde) og vær sikker på at skummende vann fra vakumpumper ikke renner inn i selve teller åpningen. 11. For å lagre tall midt i en telling (f.eks. flytting mellom merder) trykk på knappen lagre 12. Tallet i øverste venstre kollonne kan nullstilles ved å dobbeltklikke på tallet i øverste felt i skjermbildet. 13. Hvis en ønsker å rengjøre speil/glassflater, se eller åpne teller midt i en telleoperasjon kan telling stoppes ved å trykke Stop Husk å starte telleren igjen før fisk pumpes opp i telleren 14. Avslutt telling med å trykke Lagre først og deretter Avslutt 15. Se på rapport og opptak med å trykke på knappene Rapport eller Opptak 16. Skriv ut rapport og opptak på USB minne med å kopiere aaaa.mse og aaaa.blb filer som finnes på C:/Reports/. Disse kan så brennes på CD ROM etter ønske. Hvis skummende vann kommer inn i teller kan det gi skygger som tolkes som fisk eller flekker som gjør at fisk ikke blir talt. For mye fisk kan føre til undertelling Dette fører til at tallet i øverste felt i skjermbildet blir skrevet ut som en linje i rapporten sammen med tidspunkt. Dette må bekreftes med OK Nå vil telletallet nullstilles, men totalen vil fortsette å stige så lenge tellingen pågår. Dette kan være aktuelt hvis en f.eks begynner med å losse i en ny merd Når man har stoppet tellingen kan man gå inn i synsfeltet uten at telleren teller de skyggene vi måtte skape under rengjøring. Med dette lagres siste mellom-telling og telling stoppes. Det anbefales å avslutte telling før siste tømming av vakumsystemet for å hindre store vannflekker i tellingen på slutten. Her kan resultatene fra en avsluttet telling undersøkes både som rapport og video fil med silhuetter av fisken. NB: disse filene må alltid kopieres samtidig for å kunne lese opptaket (*.blb og *.mse filene). For å kunne lese filene på ekstern pc må egnet program lastes ned fra: http://www.vaki.is/vaki/products/micromacrocounter/softwareupgrades/ Vaki Aquaculture Systems 7

Vaki Aquaculture Systems 8