Date: February 27, 2013 Acme Electric Customers Product Advisory Notice Transformer Mounting Brackets Acme Electric has been notified of a potential quality issue with the mounting bracket on Acme single phase general purpose and buck boost transformers in sizes ranging from 0.25 kva to 2 kva. Please refer to the attached letter for specific details on this recall, how to identify the product(s) and what to do if items you ve purchased and/or installed are affected. Since the notice includes information for both distributors (like Fromm) and end users (you), we thought it would be helpful to provide highlights of actions items that specifically pertain to you: Inspect the date code on each unit of your inventory which is printed on a small silver sticker located on each unit s carton. If the date code falls between EIA-413-1224 (week 24 of 2012) and EIA-413-1303 (week 3 of 2013), such unit should be returned to Fromm as soon as possible. If installed, you can still inspect the date code: The date code is printed on a small silver or white sticker which is located on the outside of the metal enclosure (see enclosed photo). In the event that you have already installed any units which should have been quarantined and have further questions, please contact Acme toll-free at 1-800-334-5214 (press 3 when prompted). We re sorry for this inconvenience. If you need further assistance, please contact your Fromm salesperson. Fromm Electric Supply
Date: February 27, 2013 From: Acme Electric Distributors Acme Electric, a division of Actuant Electrical, Inc. Second Product Advisory Notice Transformer Mounting Brackets We would like to thank you for your prompt responses to the Product Advisory dated February 12, 2013 for Acme Electric transformer mounting brackets. Acme Electric has already begun filling the offsetting purchase orders and anticipates having all open orders filled within the next two weeks. Acme Electric will be supplying free replacement brackets for those transformers which fall within the scope of the original Advisory and have already been installed, if such transformers do not appear to be mounted securely. Such replacement brackets have been designed to fit over the existing transformer and can be installed by simply loosening the transformer from its mounted position. In order to notify your customers and/or end-users as to the availability of the replacement brackets, Acme Electric has prepared the enclosed Product Advisory dated February 27, 2013. We are asking for your assistance in ensuring that a copy of the new Advisory is sent to each of your customers and/or end-users which have purchased and/or installed a transformer within the scope of the original Advisory. Alternatively, we can send the new Advisory on your behalf if you provide Acme Electric the contact information for your customers and/or end-users. Please send information (in Excel format if possible) to bracket.replacements@actuant.com and title the email End User Contacts. If you have any questions regarding the new Product Advisory or desire assistance in the distribution of the new Product Advisory, please send an email to bracket.replacements@actuant.com. Sincerely yours, John Teece Product Manager Acme Electric
Date: February 27, 2013 From: Acme Electric Transformer Customers and End-Users Acme Electric, a division of Actuant Electrical, Inc. Product Advisory Notice Transformer Mounting Brackets You are receiving this Product Advisory because our records indicate that you may have purchased and/or installed one or more Acme Electric single phase general purpose and buck boost transformers in sizes ranging from 0.25 kva to 2 kva ( Transformers ) at some time during the last eighteen weeks. Since January 25, 2013, Acme Electric has received eight reports that the mounting brackets on some Transformers have come loose either during or shortly after installation. Our investigation has revealed that the mounting bracket failures are directly attributable to a quality issue with the weld between the mounting bracket and the metal enclosure. Please be advised that depending upon how the Transformer is installed or being installed at the time of a failure, such a failure could result in personal injury and/or property damage. A list of the Acme Electric part numbers which may be affected by this quality issue is attached to this Product Advisory. In the interest of safety, and to assure the highest possible quality standards, Acme Electric is asking you to immediately take the following measures: 1. Inspect the date code on each Transformer. The date code is printed on a small silver sticker which is located both on the original shipping box and on the outside of the metal enclosure (see enclosed photo). 2. If the date code falls between EIA-413-1224 (week 24 of 2012) and EIA-413-1303 (week 3 of 2013), and you suspect the Transformer is not mounted securely, has a loose mounting bracket or poses a risk of falling, then please contact the Acme Customer Service Team at 1-877-201-2445 to request a free replacement bracket. If the Transformer is securely mounted and/or is not mounted using the welded-on rear mounting bracket, no further action is necessary. 3. If the date code does not fall between the foregoing date code ranges, then the Transformer is not subject to this Product Advisory and no further action is necessary. We want to thank all of you in advance for your help in ensuring that Acme Electric customers continue to receive the high quality products they have grown to expect. If you have any questions regarding this Product Advisory, please contact the Acme Customer Service Team at 1-877-201-2445. Sincerely yours, John Teece Product Manager Acme Electric
Single Phase Transformers Buck-Boost Transformers Part Number Description Part Number Description GP121000S TRANSFORMER, 1PH 1.0KVA 277/480-208/277 T111683 TFMR:BUCK BOOST 1PH 1KVA 120X240-12X24 GP12250S TRANSFORMER, 1PH.25KVA 277/480-208/277 T111684 TFMR:BUCK BOOST 1PH 1.5KVA 120X240-12X24 GP12500S TRANSFORMER, 1PH.50KVA 277/480-208/277 T111685 TFMR:BUCK BOOST 1PH 2KVA 120X240-12X24 T253007S TFMR:1PH.25KVA 240X480-120/240 T181050 TFMR:BUCK BOOST 1PH.250KVA 120X240-12X24 T253008S TFMR:1PH.50KVA 240X480-120/240 T181051 TFMR:BUCK BOOST 1PH.500KVA 120X240-12X24 T253009S TFMR:1PH.75KVA 240X480-120/240 T181052 TFMR:BUCK BOOST 1PH.750KVA 120X240-12X24 T253010S TFMR:1PH 1.0KVA 240X480-120/240 T113073 TFMR:BUCK BOOST 1PH 1KVA 120X240-16X32 T253011S TFMR:1PH 1.5KVA 240X480-120/240 T113074 TFMR:BUCK BOOST 1PH 1.5KVA 120X240-16X32 T253012S TFMR:1PH 2.0KVA 240X480-120/240 T113075 TFMR:BUCK BOOST 1PH 2KVA 120X240-16X32 T253060 TFMR:AUTO 1PH 1.0KVA 240-120/240 T181057 TFMR:BUCK BOOST 1PH.250KVA 120X240-16X32 T253061 TFMR:AUTO 1PH 1.5KVA 240-120/240 T181058 TFMR:BUCK BOOST 1PH.500KVA 20X240-16X32 T253062 TFMR:AUTO 1PH 2.0KVA 240-120/240 T181059 TFMR:BUCK BOOST 1PH.750KVA 120X240-16X32 T253063 TFMR:AUTO 1PH 3.0KVA 240-120/240 T137920 TFMR:BUCK BOOST 1PH 1KVA 240X480-24X48 T253064 TFMR:AUTO 1PH 5.0KVA 240-120/240 T137921 TFMR:BUCK BOOST 1PH 1.5KVA 240X480-24X48 T253107S TFMR:1PH.25KVA 600-120/240 T137922 TFMR:BUCK BOOST 1PH 2KVA 240X480-24X48 T253108S TFMR:1PH.50KVA 600-120/240 T181064 TFMR:BUCK BOOST 1PH.250KVA 240X480-24X48 T253109S TFMR:1PH.75KVA 600-120/240 T181065 TFMR:BUCK BOOST 1PH.500KVA 240X480-24X48 T253110S TFMR:1PH 1.0KVA 600-120/240 T181066 TFMR:BUCK BOOST 1PH.750KVA 240X480-24X48 T253111S TFMR:1PH 1.5KVA 600-120/240 T253112S TFMR:1PH 2.0KVA 600-120/240 T279740S TFMR:1PH 1.0KVA 120/208/240/277-120/240 T279741S TFMR:1PH 1.5KVA 120/208/240/277-120/240 T279742S TFMR:1PH 2.0KVA 120/208/240/277-120/240 T353041S TFMR:1PH 1.5KVA 120X240-120/240 TF217437S TFMR:EXPORT 1PH 1.0KVA TF217439S TFMR:EXPORT 1PH 2.0 KVA TF279260S TFMR:EXPORT 1PH 1.0 KVA 240X480-120/240 TF279261S TFMR:EXPORT 1PH 2.0 KVA 240/480-120/240 TF279300S TFMR:HOLLIS-EXPORT 1 PHASE 1.0 KVA TF279301S TFMR:HOLLIS-EXPORT 1 PHASE 2.0 KVA
Date: February 12, 2013 From: Acme Electric Distributors Acme Electric, a division of Actuant Electrical, Inc. Product Advisory Notice Transformer Mounting Brackets Acme Electric has been notified of a potential quality issue with the mounting bracket on Acme single phase general purpose and buck boost transformers in sizes ranging from 0.25 kva to 2 kva. This quality condition can result in the mounting bracket coming loose from the transformer box causing the transformer to fall from its mounted position. Depending upon how the transformer is mounted or being mounted at the time of a failure, such a failure could result in potentially serious property damage and/or personal injury. A list of the Acme part numbers which may be affected by this quality issue ( Target Part Numbers ) is attached to this Product Advisory. In the interest of safety, and to assure the highest possible quality standards, Acme Electric is asking you to immediately take the following measures: 1. Issue a stop sale or quality hold on all inventory with any of the Target Part Numbers. 2. Inspect the date code on each unit of inventory which is printed on a small silver sticker located on each unit s carton (see enclosed photo). If the date code falls between EIA-413-1224 (week 24 of 2012) and EIA-413-1303 (week 3 of 2013), such unit should be quarantined and prepared for shipment back to Acme. If the unit has a date code that does not fall within this range, such unit can be returned to stock and made available for distribution. 3. To return quarantined units to Acme, contact the Acme Customer Service Team (CST) and request a Return of Goods Authorization (RGA). An offsetting purchase order for the quarantined units must be placed at the time the RGA is processed. Please e-mail your request for an RGA relating to this potential quality issue to: AcmeBrackets@actuant.com. An RMA request form will be e-mailed to you which will include further instructions. Please complete the form, including your purchase order number for the offsetting order in the spaces provided. To expedite processing of your return, please include the following information on the request form: (i) the Target Part Numbers, (ii) the quantities to be returned, and (iii) the original purchase order numbers if available. All returns must be in their original Acme Packaging. If you have any further questions, the Acme CST can be reached toll free at 1-800-334-5214 (press 2 when prompted). 4. Concurrent with steps 1-3 above, please contact all customers to whom you have sold any of the Target Part Numbers since June 1, 2012, and provide them a copy of this Product Advisory. If they have inventory within the specified date codes, please arrange to have such units shipped back to you. Please include such customer returns in your original RGA request if possible. Otherwise, please submit additional RGA requests as necessary. In the event that your customer has already installed any units which should have been quarantined, please contact Acme CST toll-free at 1-800-334-5214 (press 3 when prompted).
Acme Electric is in the process of inspecting its inventory in warehouses across the country. Units that have passed inspection are being returned to stock and made available for sale. We want to thank all of you in advance for your help in ensuring that Acme customers continue to receive the high quality products they have grown to expect. If you have any question, please contact our customer service team at 1-800-334-5214. Sincerely yours, John Teece Product Manager Acme Electric Single Phase Transformers Buck-Boost Transformers Part Number Description Part Number Description GP121000S TRANSFORMER, 1PH 1.0KVA 277/480-208/277 T111683 TFMR:BUCK BOOST 1PH 1KVA 120X240-12X24 GP12250S TRANSFORMER, 1PH.25KVA 277/480-208/277 T111684 TFMR:BUCK BOOST 1PH 1.5KVA 120X240-12X24 GP12500S TRANSFORMER, 1PH.50KVA 277/480-208/277 T111685 TFMR:BUCK BOOST 1PH 2KVA 120X240-12X24 T253007S TFMR:1PH.25KVA 240X480-120/240 T181050 TFMR:BUCK BOOST 1PH.250KVA 120X240-12X24 T253008S TFMR:1PH.50KVA 240X480-120/240 T181051 TFMR:BUCK BOOST 1PH.500KVA 120X240-12X24 T253009S TFMR:1PH.75KVA 240X480-120/240 T181052 TFMR:BUCK BOOST 1PH.750KVA 120X240-12X24 T253010S TFMR:1PH 1.0KVA 240X480-120/240 T113073 TFMR:BUCK BOOST 1PH 1KVA 120X240-16X32 T253011S TFMR:1PH 1.5KVA 240X480-120/240 T113074 TFMR:BUCK BOOST 1PH 1.5KVA 120X240-16X32 T253012S TFMR:1PH 2.0KVA 240X480-120/240 T113075 TFMR:BUCK BOOST 1PH 2KVA 120X240-16X32 T253060 TFMR:AUTO 1PH 1.0KVA 240-120/240 T181057 TFMR:BUCK BOOST 1PH.250KVA 120X240-16X32 T253061 TFMR:AUTO 1PH 1.5KVA 240-120/240 T181058 TFMR:BUCK BOOST 1PH.500KVA 20X240-16X32 T253062 TFMR:AUTO 1PH 2.0KVA 240-120/240 T181059 TFMR:BUCK BOOST 1PH.750KVA 120X240-16X32 T253063 TFMR:AUTO 1PH 3.0KVA 240-120/240 T137920 TFMR:BUCK BOOST 1PH 1KVA 240X480-24X48 T253064 TFMR:AUTO 1PH 5.0KVA 240-120/240 T137921 TFMR:BUCK BOOST 1PH 1.5KVA 240X480-24X48 T253107S TFMR:1PH.25KVA 600-120/240 T137922 TFMR:BUCK BOOST 1PH 2KVA 240X480-24X48 T253108S TFMR:1PH.50KVA 600-120/240 T181064 TFMR:BUCK BOOST 1PH.250KVA 240X480-24X48 T253109S TFMR:1PH.75KVA 600-120/240 T181065 TFMR:BUCK BOOST 1PH.500KVA 240X480-24X48 T253110S TFMR:1PH 1.0KVA 600-120/240 T181066 TFMR:BUCK BOOST 1PH.750KVA 240X480-24X48 T253111S TFMR:1PH 1.5KVA 600-120/240 T253112S TFMR:1PH 2.0KVA 600-120/240 T279740S TFMR:1PH 1.0KVA 120/208/240/277-120/240 T279741S TFMR:1PH 1.5KVA 120/208/240/277-120/240 T279742S TFMR:1PH 2.0KVA 120/208/240/277-120/240 T353041S TFMR:1PH 1.5KVA 120X240-120/240 TF217437S TFMR:EXPORT 1PH 1.0KVA TF217439S TFMR:EXPORT 1PH 2.0 KVA TF279260S TFMR:EXPORT 1PH 1.0 KVA 240X480-120/240 TF279261S TFMR:EXPORT 1PH 2.0 KVA 240/480-120/240 TF279300S TFMR:HOLLIS-EXPORT 1 PHASE 1.0 KVA TF279301S TFMR:HOLLIS-EXPORT 1 PHASE 2.0 KVA