1 INTRODUKSJON IFES BRENSELSLAGRE FOR METALLISK BRENSEL UNDERSØKELSER AV LAGRET BRENSEL

Størrelse: px
Begynne med side:

Download "1 INTRODUKSJON IFES BRENSELSLAGRE FOR METALLISK BRENSEL UNDERSØKELSER AV LAGRET BRENSEL"

Transkript

1 IFE/KR/F-2013/009 Oppfølging av sikkerhet og videre håndtering av brukt aluminiumkapslet, historisk metallisk brensel i JEEP I stavbrønn og HBWR-bunker

2

3 1 Innholdsfortegnelse 1 INTRODUKSJON SIKKERHETSPRINSIPPER FOR LAGRING AV BRUKT BRENSEL NASJONAL STRATEGI FOR HÅNDTERING AV BRUKT BRENSEL ANBEFALINGER FRA TEKNISK UTVALG OG STRANDENUTVALGET IFES BRENSELSLAGRE FOR METALLISK BRENSEL JEEP I STAVBRØNN HBWR BUNKER UNDERSØKELSER AV LAGRET BRENSEL METODIKK RESULTATER JEEP I STAVBRØNN HBWR VURDERING AV FUNN OG TILHØRENDE RISIKO JEEP I STAVBRØNN UTVIKLING AV HYDROGENGASS FUKTIGHET DANNELSE AV URANHYDRID SAMLET RISIKOVURDERING STAVBRØNN HBWR VIDERE ARBEID SIKKERHET OG STABILISERING SIKKERHET SOM STYRENDE PRINSIPP MINIMERE HÅNDTERING FØR STABILISERING OPPDATERT SIKKERHETSDOKUMENTASJON TILPASSET BEREDSKAP OG OVERVÅKING VIDERE KARAKTERISERING IFES OPPFØLGING KONKLUSJON REFERANSER VEDLEGG

4 2 Figurliste Figur 1 JEEP I stavbrønn, Kjeller Figur 2 Nøytronradiografi (øverst i avbildningen) viser hvite, hydrogenrike områder på brenselsstaven (UH 3 og H 2 ), på steder hvor visuell inspeksjon viser korrosjonsangrep i Alkapslet brensel. Korrosjonsangrepene er synlige enten som blemmer eller pittings (grop) i Alkapslingen (brensel fra JEEP I stavbrønn) Figur 3 Metallografisk tverrsnitt av brenselselement 25 viser korrosjonsangrep / hydrering av det metalliske U-brenselet. Snittet går gjennom blemmen i Al-kapslingen og det hydrerte, korroderte området (UH 3 ) i U-brenselet (brensel fra JEEP I stavbrønn).... 8

5 3 1 Introduksjon Med utgangspunkt i Strandenutvalgets forslag til «prosessen videre ved klarlegging av den best egnede tekniske løsningen for behandling av norsk, instabilt metallisk uran for sikker lagring i framtiden og egnet lokalisering for mellomlagring av brukt brensel og langlivet middelaktivt avfall». har Avdeling NMAT gjennomført undersøkelser og samlet dokumentasjon (se vedlegg) om tilstanden til det historiske brenselet lagret på Kjeller og i Halden. Undersøkelsene gjelder arbeidspunktet som omhandler «å skaffe en oversikt over brukt brensel og avfall i tidsrammen ». Dokumentasjonen ble systematisert og presentert under Teknisk Utvalgs arbeid i 2009 /1/ som inngikk i Strandenutvalget /2/. I tråd med oppfølgingen av anbefalingene fra Teknisk Utvalg og Strandenutvalget er det blitt gjennomført undersøkelser av metallisk brensel lagret i JEEP I stavbrønn på Kjeller og ved lageret ved Haldenreaktoren. Arbeidet ble dokumentert i to rapporter (vedlegg A1, A2). En del av prosjektet var en masteroppgave som ble levert september 2012 ved Chalmers, Gøteborg. I tillegg er det blitt samlet og evaluert relevante tekniske data om det metalliske brenselet. Dette er tegninger og faktiske data om brenselet som blant annet brenselstyper, utbrenning, brenselshistorikk, tilstandsdokumentasjon av kapslingen og eventuelle brenselsfeil. Videre evalueringen av de innsamlede data skal gi grunnlag for utarbeidelse av en detaljert plan for videre arbeid slik IFE nå har tatt initiativ til (se kapittel 5). Denne rapporten beskriver funnene sammen med en foreløpig vurdering for nødvendige tiltak for å ivareta sikkerheten, og hvordan funnene understreker behovet for en nasjonal plan for videre håndtering og lagring av dette materialet. 1.1 Sikkerhetsprinsipper for lagring av brukt brensel IFEs overordnete tilnærming er at all virksomhet skal være sikker, og at sikkerheten skal være ivaretatt ved: - at sikkerhet alltid er et overordnet hensyn, foran økonomiske og driftsmessige forhold. - å forebygge og forhindre helse- og miljøskader fra IFEs virksomhet, og å beskytte Instituttets utstyr, eiendom og omgivelser mot tap og skader. - at Instituttets tekniske installasjoner, anlegg og laboratorier skal være konstruert, bygget, drevet og vedlikeholdt på en slik måte at sikkerhetsmessige krav alltid er ivaretatt og etterleves. Sikkerhetsprinsippene IFE arbeider etter er basert på IAEAs anbefalinger og nasjonale krav og kan oppsummeres som forsvar i dybden som er et sett av tekniske og administrative tiltak for å forebygge eventuelle uhell og dempe konsekvensene hvis uhell skulle inntreffe. Forsvar i dybden omfatter tiltak for å beskytte allmennheten og miljøet mot skader hvis barrierene ikke er fullstendig effektive. Satt i system skal de tekniske og administrative tiltakene alltid ivareta de tre grunnleggende kontrollfunksjonene for reaktoranlegg og håndtering av kjernebrensel: kjøling, kritikalitet og innkapsling av radioaktive stoffer. Ved å påse at disse tre basisfunksjonene er sikret, ivaretas samtidig sikkerheten til anlegget og dermed allmennheten. For brukt brensel er det sentralt å kapsle inn de radioaktive stoffene. Brenselet genererer svært lite varme ettersom utbrenningen er lav og siden det har vært lagret i mange år allerede. Kritikalitet er utelukket siden brenselet har lav anrikning og står lagret i posisjoner

6 4 med god innbyrdes avstand. Når det gjelder innkapsling, er det avgjørende å holde vann utenfor fra å trenge inn, spesielt direkte inn mot selve brenselsmatrisen. Sikkerheten for IFEs brenselslagre for metallisk brensel er vurdert i sikkerhetsrapportene for JEEP I stavbrønn og for Haldenreaktoren /3, 4/. For hver gjennomgang av sikkerheten i forbindelse med nye konsesjoner har IFE revidert sikkerhetsrapportene og lagt disse til grunn for sin søknad om fornyet konsesjon under atomenergiloven. Statens strålevern har i neste omgang vurdert IFEs rapporter og tatt initiativ til endringer enten som en del av konsesjonsbehandlingen eller som en del av vilkårene for konsesjon. Sikkerheten for begge lagrene ble vurdert til å være tilfredsstillende da konsesjon ble gitt i 2008 /5/. 1.2 Nasjonal strategi for håndtering av brukt brensel Fra slutten av 1990-tallet har statlige myndigheter i Norge søkt å etablere en overordnet nasjonal strategi for håndtering av brukt brensel. Berganutvalget ( ) anbefalte en nasjonal strategi for sluttbehandling og deponering av brukt kjernebrensel i Norge /6/. I 2004 ble Fase 1-utvalget etablert for blant annet å identifisere kritiske forhold med hensyn til valg av tekniske løsninger og et mandat for videre utredninger /7/. Mandatet for videre utredninger ble lagt til grunn for det såkalte Fase 2-utvalget (Strandenutvalget) som ble etablert i Samtidig ble det også etablert et Teknisk Utvalg for å utrede stabilisering og sikker lagring av metallisk uranbrensel og brensel med aluminiumskapsling. Utredningen fra Teknisk Utvalg var en selvstendig rapport bestilt av Nærings- og handelsdepartementet (NHD), samtidig som den inngikk i beslutningsgrunnlaget for Strandenutvalget. Teknisk Utvalg kom i 2010 med en entydig anbefaling om å stabilisere brenselet ved et dertil egnet anlegg. Slike anlegg finnes ikke i Norge. Som oppfølging av Teknisk Utvalg anbefalte Strandenutvalget at for brukt brensel bør «informasjon om konstruksjon, materialegenskaper, historikk og tilstand systematiseres og kompletteres» /2/. Begge rapportene er gjennomgått og vurdert av Statens strålevern /9/. IFE støttet konklusjonene fra Teknisk Utvalg og fra Strandenutvalget /10/. Spesielt pekte IFE på Strandenutvalgets initiativ om en forstudie for håndtering av metallisk brensel. Forstudien bør avklare om det er mulig å gjennomføre forsendelse av brensel for opparbeiding, som ledd i en stegvis prosess. De siste funnene har ytterligere aktualisert dette. Det ble for øvrig presisert fra IFEs side at Instituttet ikke kan delta i strategiske valg knyttet til norsk brenselssyklus i fremtiden. Så langt har utredningsarbeidet ikke resultert i en nasjonal strategi eller en beslutning for hvordan videre håndtering og deponering av brukt brensel i Norge skal foregå. NHD har for 2013 for øvrig satt av ressurser til å starte en konseptvalgutredning Anbefalinger fra Teknisk Utvalg og Strandenutvalget I rapporten fra Teknisk Utvalg blir det angitt hvilke tekniske utfordringer som generelt er knyttet til aluminiumskapslet metallisk uranbrensel: «Metallisk uran er pyrofort (selvantennelig i luft) og reagerer med vann slik at det dannes hydrogengass og pyrofort uranhydrid. Aluminiumskapsling reagerer med vann og danner hydrogengass og kan dessuten utsettes for en omfattende, alvorlig lokal korrosjon som kan ødelegge kapslingen og frilegge det metalliske uranbrenselet.» /1/.

7 5 Blandingen av metallisk uran, uranhydrid og hydrogen er reaktivt i romtemperatur og har historisk medført hendelser i form av brann og spontane reaksjoner. Dette er forhold som vil påvirke valg av senere løsninger for lagring og deponering. Dette er mer detaljert beskrevet i rapporten fra Teknisk Utvalg og ulike andre kilder /11, 12, 13/. De rapporterte uhellene internasjonalt har i særlig grad vært knyttet til håndtering av materialet. For eksempel har sterkt korroderte brenselselementer blitt mistet i gulvet ved håndtering eller ved transport. Det er også rapportert om uhell som følge av at lagringsbeholdere med en hydrogenatmosfære åpnes og luft slipper inn. En rekke land har også beskrevet behovet for tiltak og hvordan disse er blitt implementert. Eksempelvis ble korrosjonsskadet brensel fra den svenske R1-reaktoren satt i en kontrollerbar atmosfære gjennom uttak av brensel under overvåkning, jevnlig kontroll av atmosfæren rundt brenselet, før endelig stabilisering og prosessering startet i 2009 /14/. Gjennomføring av slike tiltak der særskilte anlegg bygges opp er tiltak som er nært knyttet til en nasjonal strategi for håndtering av brukt brensel slik dette har vært vurdert av de ulike norske offentlige utvalgene. 2 IFEs brenselslagre for metallisk brensel Brukt brensel i Norge stammer fra driften av JEEP I og II reaktorene og noe fra NORAreaktoren på Kjeller, samt Haldenreaktoren. Noe av dette brenselet kan plasseres direkte i et deponi, mens det øvrige brenselet har dårlig lagringsbestandighet. En vesentlig del av den siste gruppen er metallisk brensel. Avdeling NMAT har dokumentasjon for alle lagrede brenselselementer ved Haldenreaktoren og i JEEP I stavbrønn (vedlegg A3 A7). Denne ble presentert for det offentlig nedsatte Teknisk Utvalg i Dokumentasjonen gir informasjon om utbrenningshistorikk og i noen tilfeller informasjon fra observasjoner gjort fremover i tid etter innplasseringen i lageret. Omlastningen i 1982 er markert spesielt på alle kortene. Den siste oppføringen er innplasseringen av et mindre antall elementer i På kortene er det markert om elementene har merker eller defekter i kapsling og/ eller brensel. Detaljert informasjon om brenslet bør av sikringshensyn unntas offentlighet. Dette gjelder informasjonen i vedleggene (A1 A7). For øvrig vises det til innførte sikringstiltak godkjent av Statens strålevern, revidert og godkjent trusselvurdering (DBT), samt sårbarhetsanalyse for reaktoranlegget i Halden. 2.1 JEEP I stavbrønn JEEP I stavbrønn er et vertikalt tørrlager med hovedsakelig lagret standardbrensel fra JEEP I noe eksperimentalbrensel fra JEEP I, fra NORA-reaktoren og fra Haldenreaktoren. Lageret er beskrevet i sikkerhetsrapporten for anlegget /3/. Lageret består av et betongfundament som er støpt på bakkenivå og en betongsåle støpt ca. 3 meter under bakkenivå. Det er 97 hull (pits) i fundamentet og i hvert hull er det festet et 2,7 meter langt stålrør som er støpt fast i den 0,2 meter tykke betongsålen. Toppen av hvert rør er dekket med et metalldeksel og ekspanderende pakning. Volumet rundt rørene mellom betongsålen og betongfundamentet er fylt med sand, fin pukk og en drenerende masse. Lagerposisjonene er forseglet med jernskinner som er skrudd fast med bolter og hele lageret er dekket med en aluminiumsplate som er forseglet av IAEA.

8 6 Figur 1 JEEP I stavbrønn, Kjeller. I JEEP I stavbrønn er det brensel i 93 av 97 lagringsplasser (pits). I hver lagringsplass er det en rustfri stålbeholder (kvalitet 304L) med vanntette lokk, og hver beholder er senket ned i en pit, dvs. i de innstøpte stålrørene i stavbrønnen. Lagringsbeholderen inneholder et standard brenselselement. I få tilfeller er det 2 mindre elementer i en lagringsbeholder Brenselet i lagringsbeholdere i 71 pits er standard JEEP I brenselselementer med naturlig anriket, metallisk uran, dvs. JEEP I standardbrensel. 22 pits til sammen er lager for lagringsbeholder med brensel av forskjellig design, dette er HBWR type metalliske uranbrenselselementer, brenselselementer med lav anriket, bestrålt UO 2, eller ThO 2, og «void» elementer med UO 2 brensel. Brenselsstavene består av et kapslingsrør av aluminium fylt med uranbolter (slugs) med en diameter av 2,54 cm. Innhold og visuelle observasjoner for hver lagringsplass er beskrevet i vedlegg. Lagerbeholdning, historikk og tilstand med resultatene fra de tidlige observasjonene på 50- og 60-tallet er spesifisert i rapporten til Teknisk Utvalg /1/. JEEP I stavbrønn inngår i Met. Lab. IIs driftsområde og er dermed tillagt avd. NMAT. Anlegget er omfattet av IFEs konsesjon for drift av instituttets atomanlegg som går ut i 2018 /5/. Jeep I stavbrønn er et statisk lager uten endringer mht. mengden nukleært materiale. 2.2 HBWR-bunker Horisontalt hovedlager består av 202 horisontale stållommer for lagring av bestrålt brensel. Lageret er beskrevet i sikkerhetsrapporten for Haldenreaktoren /4/. Hver element har en brenselsstav med aluminiumskapsling og metallisk uran brensel. Hver HBWR I brenselselement inneholder kun en brenselstav. Brenselsstaven består av et kapslingsrør av aluminium fylt med uranbolter (slugs). Hver element er plassert for lagring i en Al beholder med tett lokk. Lagringsbeholderen er vanntett. Rundt lageret er det en 2 meter tykk betongsskjerm, og fronten er skjermet med en 1 meter tykk plate av tungbetong. I hver av stållommene er det 7 meter lange horisontale stålrør. Inne I betongkonstruksjonen er det en metallkonstruksjon som støtter rørene som utgjør lagerposisjoner. Lageret kjøles av luft, og luften ventileres ved naturlig sirkulasjon over taket til bunkerbygningen. Lagerbeholdning, historikk og tilstand, i tråd med informasjonen i

9 7 vedleggene, ble presentert for Teknisk Utvalg. I motsetning til beskrivelsene for JEEP I stavbrønn har det ikke vært rapportert tidligere om blemmer o.l. for brensel i HBWR-bunker. Brenselslageret for metallisk brensel i Halden inngår i ansvaret til avdeling Reaktordrift. Anlegget er omfattet av IFEs konsesjon som går ut 31. desember Det eneste anlegget som ikke er omfattet av denne er Haldenreaktoren der konsesjonen går ut 31. desember IFE har i sin søknad om fornyet konsesjon frem til 2024 også inkludert brenselslagrene i Halden /8/. 3 Undersøkelser av lagret brensel IFE har i 2011 og 2012 gjennomført ulike typer undersøkelser av brenselselementer fra JEEP Is første brenselsladning fra 1951 og av HBWRs første brenselsladning fra Utformingen av undersøkelsene skjedde på bakgrunn av relevante og tilgjengelige metoder, og etter anbefalinger fra Teknisk Utvalg og Strandenutvalget. Utvelgelse, metodikk og resultater er utførlig beskrevet i vedlegg A1 og A2, for detaljer og fullstendige beskrivelser henvises det derfor til disse rapportene. Undersøkelsene omfattet 5 brenselselementer fra Halden og ett element fra JEEP I stavbrønn. Elementene fra HBWR ble valgt ut fra observasjoner beskrevet i dokumentasjonen, utbrenning, hvor i reaktoren disse hadde vært plassert og med sikte på å velge representative elementer for resten av lagrene. Brenselshistorikken for elementene fra Haldenreaktoren viser at de har vært i reaktoren fra oppstart av reaktoren i Etter dette har elementene vært lagret i Halden. Brenselet valgt fra lageret i Halden har vært eloksert, i motsetningen til elementet fra JEEP I stavbrønn. Brenselshistorikken for elementet fra JEEP I stavbrønn beskriver at dette elementet var i bruk i reaktoren fra Etter dette har elementet vært lagret på Kjeller. Brenselselementet nr. 25 fra JEEP I i pit nr. 94 ble valgt fordi det stråler lite og kunne dermed transporteres fra JEEP I stavbrønn til Met. Lab. II uten skjerming. Dessuten var det beskrevet at byller o.l. var observert tidligere. Elementet ble visuelt undersøkt i Brenselet har relativt lav utbrenning. 3.1 Metodikk Preparasjons- og undersøkelsesteknikker ble innøvet på relevante ubestrålt testmaterialer fra tidlig 50-tallet. For å identifisere adekvate metallografiske metoder for hvert av disse materialene og for å samle inn data som grunnlag for sammenligning med resultatene fra bestrålt brensel. Undersøkelsen av elementet fra JEEP I stavbrønn omfattet demontering av brenselselementet, ekstraksjon av elementets to brenselspinner, deretter visuell inspeksjon av hele elementet og hver av pinnene samt nøytronradiografi av en av brenselspinnene. Det ble tatt prøver av brenselspinnen for metallografisk undersøkelse, dvs. hardhetstesting, optisk mikroskopi og elektronmikroskopi. For brenselet fra Halden omfattet undersøkelsene visuell inspeksjon og gammasprektralanalyse.

10 8 3.2 Resultater JEEP I stavbrønn Undersøkelsene viser at årsaken til «blemme/blemmer», eller engelsk blister notert på kartotekkortet, er lokal korrosjon/hydrering. Denne korrosjonsinduserte volumøkningen forårsaker en lokalt avgrenset utbylling av Al-kapslingen. Blemmene skyldes dannelse av uranhydrid. Figur 2 Nøytronradiografi (øverst i avbildningen) viser hvite, hydrogenrike områder på brenselsstaven (UH 3 og H 2 ), på steder hvor visuell inspeksjon viser korrosjonsangrep i Al-kapslet brensel. Korrosjonsangrepene er synlige enten som blemmer eller pittings (grop) i Al-kapslingen (brensel fra JEEP I stavbrønn). Figur 3 Metallografisk tverrsnitt av brenselselement 25 viser korrosjonsangrep / hydrering av det metalliske U-brenselet. Snittet går gjennom blemmen i Al-kapslingen og det hydrerte, korroderte området (UH 3 ) i U-brenselet (brensel fra JEEP I stavbrønn).

11 9 Figur 2 viser bilder av karakteristiske Al-kapslingsmerker på brensel fra JEEP I stavbrønn, dvs. «pittings og blemmer». Utseende av pittings og blemmer er vist i visuelle inspeksjonsbilder, nederst i figur 2. Ved hjelp av nøytronradiografi ble det gjennomført en hydrogenfordelingsanalyse. Figur 2 øverst viser område med kapslingsmerker. Nøytronradiografi dokumenterer hydrogenanrikningen med lyse flekker i området med «pittings og/eller blemmene». Figur 3 viser et tverrsnittsbilde av det samme brenselet. I Figur 3 ser man at kapslingen er tett til tross for utbulingen som følge av dannelse av uranhydrid. Gjennom disse undersøkelsene er det blitt verifisert at de kvalitative observasjonene som er notert om JEEP I stavbrønn når det gjelder brenselets utseende og korrosjonstegn (blemmer, sprekker etc.), stemmer med dagens observasjoner av det undersøkte brenselet HBWR Undersøkelsen av brenselet fra lagerbeholdningen i tørrlageret i Halden viser at kapslingen av de undersøkte brenselselementene ikke viser blemmer eller antydning til uranhydriddannelse. Stikkprøvene viser at det også her er kvalitativt samsvar mellom observasjonene gjort i 2012 og noteringene på kartotekkort. Det som var av irregulariteter vurderes å representere liten risiko for uønskete reaksjoner. Det anbefales likevel å gjøre grundigere undersøkelser. 4 Vurdering av funn og tilhørende risiko I dette kapitlet blir funnene kort oppsummert sammen med en vurdering av hvordan de kan ha oppstått, gitt tilgjengelige opplysninger for håndtering av dette brenselet frem til i dag. Det er lagt særlig vekt på å vurdere resultatene opp mot IFEs sikkerhetsmessige prinsipper for de nukleære anlegg og videre arbeid. 4.1 JEEP I stavbrønn Funnene samsvarer kvalitativt med funn fra visuell undersøkelse av brenselet i JEEP I stavbrønn fra 1982, hvor det ble funnet tilsvarende defekter på brenselet. Det kan ikke konkluderes med i hvilken grad det undersøkte elementet er representativt for de andre elementene i JEEP I stavbrønn. Det er rimelig å anta at de defektene som er notert tidligere, er reelle defekter i likhet med dem som ble funnet på det undersøkte brenselet. Det kan antas at tilstanden for elementer produsert tidlig kan være dårligere enn tilstanden for elementer produsert senere. Dette skyldes at de tidligste elementene ikke ble eloksert, det vil si at kapslingsmaterialet ikke fikk et beskyttende oksidsjikt på inn- og utside ved konstruksjon av brenselet (se også kapittel 4.2). Funnet av uranhydrid i brenselet indikerer at det har vært eller er vann eller hydrogen tilgjengelig i brenselet. Den sannsynlige årsaken til dette er fuktighet, og disse forholdene, sammen med mulige årsakssammenhenger og konsekvenser, diskuteres derfor mer i detalj nedenfor Utvikling av hydrogengass Aluminiumskapsling kan bli skadet gjennom pitting-korrosjon. Det finnes defekter i Alkapslingen til noen elementer. Dette kan føre til vanninntrenging i uranbrenselet. Skadene

12 10 har oppstått ved at kapslingen har sprukket opp. Det er ikke bekreftet at disse sprekkene går gjennom hele kapslingen. Hydrolyse av vann fører til dannelse av hydrogengass. En annen mekanisme for produksjon av hydrogen i brenselsmatrisen er at det oppstår fra hydridet selv. Sprekkdannelse kan være forårsaket av hydrogenatomer som har bygget seg opp i matrisen, re-kombinert til hydrogen i gassform. Hydrogengass inne i brenselet og i lagringsbeholderne representerer en risiko det må tas hensyn til ved undersøkelser, karakterisering, håndtering og transport av brenselet. I gjennomføring av undersøkelsene av lagrene med brensel fra HBWR og JEEP I ble det tatt nødvendige forholdsregler Fuktighet JEEP I brenselselementer er pakket i tette lagringsbeholdere av rustfritt stål med skrulokk. Hver lagringsbeholder står i en lagringsposisjon. Et hovedpoeng er å kunne verifisere at det ikke er vann til stede i elementene. På starten av 1980-tallet ble det gjennomført flere tiltak for å utbedre problemer med fuktighet i stavbrønnen. Både fuktighet som følge av kondens og innlekkasje av grunnvann ble da registrert. En annen sannsynlig årsak til at fuktighet på et tidlig tidspunkt kan ha kommet i kontakt med brenslet er at dette skjedde under produksjon, bestråling i reaktoren og/ eller under tidlig lagring i vann. Ved neste stikkprøveundersøkelse i 2009 hadde brønnene intakte stålrør og ingen fukt i bunnen, det vil si på 4,5 meters dyp. Disse undersøkelsene fant sted etter at man, pga. kalkutslag og sprekker i betongen ved årtusenskiftet ble klar over at lageret trengte en betongrehabilitering. Lageret ble undersøkt av Multiconsult gjennom en visuell kontroll av grunnvannsnivå og inspeksjon av tilstanden til tre brønner ved hjelp av et nedsenkbart videokamera. Under rehabilitering ble deler av det øverste betonglaget fjernet og ny, armert betong ble støpt på plass. All betong ble malt med pustende maling. I brønnen består hver lagringsposisjon av et rør som er støpt fast i en sementsåle. Det ble i 2006 montert en detektor i grunnen i flukt med lagerbygningen. Den vil gi alarm om fuktighet, og detektoren har ikke gitt alarm. På denne bakgrunn er det sannsynlig at eventuell fuktighet i brenselselementene har kommet til brenselet under drift i JEEP I reaktoren allerede fra eller under den videre lagringen på 50-tallet som fant sted i vann. Dette kan forklare at lignende visuelle observasjoner ble registrert i undersøkelsene i som var gjort tidligere. Slik brenselet står i dag i aluminiumskapsling, stålbeholdere, men da fortsatt med en mulighet for fukt, er det en mulighet for korrosjon gjennom galvaniske reaksjoner Dannelse av uranhydrid Uranhydrid (UH 3 ) er identifisert i det undersøkte brenselet i JEEP I stavbrønn. Dette kan ha blitt generert ved en reaksjon der uranbrenselet reagerer med vann eller hydrogen. H 2 gassdannelse og korrosjonsangrep med UH 3 er uønsket. Ved funn av slikt materiale kan det ikke utelukkes spontane reaksjoner. Dette avhenger av karakteristika for korrosjonsproduktet, dvs. hydridmaterialet, så som partikkelstørrelse, morfologi, mengde og distribusjon av hydridmaterialet, fysiske påvirkninger som friksjon, trykk, kjemiske

13 11 påvirkninger (som sammensetning) og egenskaper av omgivelsesatmosfære (fukt) og temperatur. Hydridmaterialet som er påvist i det undersøkte brenselselementet fra JEEP I stavbrønn er begrenset i omfang. Det er lite oksygen tilgjengelig slik at videre reaksjoner er lite sannsynlig. På bakgrunn av hydridets egenskaper som skissert ovenfor, der blant annet tilført energi spiller en viktig rolle, er det allikevel naturlig å ikke foreta noen videre operasjoner (håndtering, videre undersøkelser etc.) før dette er risikovurdert Samlet risikovurdering - stavbrønn Sentrale forhold ved det brukte brenslet i JEEP I stavbrønn og lageret tilstand tilsier at den overordnete risikoen for hendelser er lav. Lageret inneholder flere barrierer mot utslipp; lagerbrønnen, lagringsbeholderen av rustfritt stål til hvert brenselselement, kapsling samt brenselsmatrise. Selv om det er registrert defekter på brenselsmatrisen og på kapslingen til enkeltelementer, utgjør kapslingen en viktig barriere mot inntrengning av vann og luft. Det er sannsynlig at hydriddannelsen skjedde i en tidlig fase av lagringen på bakgrunn av tilgjengelig fukt under produksjon, bruk og/ eller tidlig lagring. Dette samsvarer kvalitativt med de visuelle observasjonene som er gjort i når disse vurderes opp mot tidligere observasjoner. Det er derfor sannsynlig at de forandringene som er synlige i dag, oppsto tidlig og at utviklingen går sakte eller har stanset. Fritt hydrogen var på samme måte sannsynligvis først og fremst tilgjengelig i en tidlig fase på bakgrunn av fuktproblemene, men det kan ikke utelukkes at dette kan frigjøres fra hydridmaterialet også nå. Imidlertid er det lite luft tilgjengelig siden defektene har mindre betydning for kapslingens tetthet, Brenselet har også lav utbrenning og lang hendøingstid (60 år), noe som gjør at det er lite varme tilgjengelig til å initiere reaksjoner i brenselet. Det vurderes derfor som lite sannsynlig at det vil oppstå spontane reaksjoner i det lagrete brenslet. På grunn av at eventuelle reaksjoner vil generere lite energi som følge av lite tilgjengelig materiale som fremmer reaksjonen, er det vanskelig å se for seg hendelser som kan føre til kontaminering ut over den rustfrie stålbeholderen og lagerbrønnen. Dette vil gi liten påvirkning på luft og vann. Som en oppsummering kan man da slå fast at mens kjøling og kritikalitet ikke er relevante problemstillinger, tilsier de funnene som nå er gjort at den nødvendige innkapsling av radioaktive stoffer er til stede. Funnene understreker imidlertid behov for videre tiltak og stabilisering. Det er ønskelig å begrense håndteringen av brenselet før mer detaljerte risikovurderinger av håndtering er gjennomført. 4.2 HBWR En rekke forhold, i tillegg til observasjoner og resultatet av undersøkelsene, gjør allikevel at status for lagring av metallisk brensel ved anlegget i Halden vurderes som sikkerhetsmessig bedre enn status for lagring av slikt brensel i JEEP I stavbrønn. For det første ble brenselet for Haldenreaktoren eloksert, For det andre er lageret i Halden over bakkenivå og har kontinuerlig lufttilførsel mellom rørene som fører til mindre risiko for vanninntrenging og lokalisert korrosjon. De identifiserte funnene, i undersøkelser og dokumentasjon nødvendiggjør videre undersøkelser og karakterisering for å få bedre data på utviklingstrekk i brenselet også for lageret i Halden, samt mer detaljert oversikt over tilhørende risiko. En ny vurdering vil også

14 12 omfatte behov for andre undersøkelsesmetoder og eventuelt nytt utstyr for gjennomføring av disse. Det er ønskelig å begrense håndteringen av brenselet lagret også ved Haldenreaktoren før mer detaljerte risikovurderinger av håndtering er gjennomført. 5 Videre arbeid sikkerhet og stabilisering Av sikkerhetsmessige hensyn er det avgjørende å beholde innkapslingen av radioaktiviteten i brenselsmatrisen, i aluminiumskapslingen, stålbeholderen og i selve lageret. På bakgrunn av funnene vil integriteten til selve brenselsmatrisen, kapslingen og risikoen for hendelser bli vurdert i det videre arbeidet. Det primære målet er å fjerne brenselet hurtigst mulig for stabilisering, og i mellomtiden gjennomføre nødvendige tiltak som ivaretar sikkerheten til brenselet. Sammenlignet med nyere oksidbrensel vil det være riktig å prioritere en løsning for det metalliske brenselet. Dette gjelder spesielt brenselet i JEEP I stavbrønn. Tilgjengelig informasjon om brenselet er ytterligere systematisert gjennom denne rapporten med vedlegg og dermed gjort tilgjengelig for relevante myndigheter, spesielt i forhold til etablering av en nasjonal strategi for videre behandling, stabilisering og mellomlagring. 5.1 Sikkerhet som styrende prinsipp På bakgrunn av de funn som er gjort i JEEP I stavbrønn, er det klart at videre undersøkelser i dette lageret ikke skjer uten at det gjennomføres detaljerte undersøkelser på hvilken måte arbeidet kan påvirke sikkerheten. Dette gjelder i de enkelte lagerposisjoner, mellom lagringsposisjonene, samt rundt lageret over og under grunnen. IFE vil i utgangspunktet ikke gjennomføre lignende undersøkelser som nå er gjort uten at nærmere risikovurderinger er gjennomført. Tiltak med utgangspunkt i en slik risikovurdering kan for eksempel omfatte kontrollerbar atmosfære, dertil egnete lagringsbeholder og anlegg for særlige undersøkelser av slikt brensel. Dette vil nå bli vurdert gjennom IFEs prosjektgruppe som er etablert for å koordinere vurderingene av videre tiltak. 5.2 Minimere håndtering før stabilisering For å redusere risikoen ved håndtering av dette brenselet, bør antall prosesser for håndtering frem til stabilisering minimaliseres. Teknisk Utvalg har gjort en vurdering av mulige behandlingsmåter for dette brenselet og konkluderer at opparbeiding ved et gjenvinningsanlegg er i dag eneste realistiske alternativ. For IFE er det viktig å arbeide for den sikkerhetsmessig beste løsningen for dette brenselet, gitt status og utvikling, og det krever at brenselet på en eller måte stabiliseres. Blant de anleggene som er tilgjengelige, vurderer Strandenutvalget anlegget i Cap LaHague som eneste aktuelle alternativ. Møtereferatet mellom AREVA og Teknisk Utvalg er tydelig i at «There were no obvious reasons why the fuels can not be reprocessed by AREVA NC», selv om det er flere forhold som må avklares. Undersøkelser av brenselet vil være av vesentlig betydning for arbeidet med å forberede brenselet for en endelig løsning. For IFE vil det derfor være naturlig i det videre arbeidet å følge anbefalingene fra Teknisk Utvalg og karakterisere brenselet i samarbeid med relevante aktører for stabilisering av brenselet. En produktiv prosess sikkerhetsmessig videre vedrørende demontering, ompakking, karakterisering og

15 13 dokumentasjon av brenselet er basert på spesifikasjoner som finnes hos relevante etterbehandlingsanlegg og aktuelle transportselskaper. 5.3 Oppdatert sikkerhetsdokumentasjon Dagens sikkerhetsrapport for JEEP I stavbrønn har vurdert brann og vannlekkasje som mulige ulykkesscenarier. Brann omhandler trekonstruksjonen i bygningen, mens vanninntrenging er vurdert som ikke realistisk. Sikkerhetsdokumentasjon for lagrene på Kjeller og i Halden skal oppdateres for å reflektere risiko ved reaksjon med vann, hydrogen og uranhydrid. 5.4 Tilpasset beredskap og overvåking Beredskapsplanen skal oppdateres gjennom å vurdere beredskapstiltak som er tilpasset andre typer uhell enn det som i dag er spesifisert i sikkerhetsrapporten, og å utvide overvåkingen av lagret med spesiell tanke på utvikling av hydrogen. Tiltakene skal bygge på en detaljert risikovurdering og prosjektering. 5.5 Videre karakterisering Innhold og omfang av videre karakterisering avhenger av tilgjengelig utstyr og anlegg, samt hvilken prosess som fastlegges for håndtering av brenselet. Eksempelvis krever nye, omfattende undersøkelser for karakterisering av brenselsstavene fra JEEP I anlegg som i dag ikke finnes i Norge på bakgrunn av at elementene er særlig lange. Både sikkerhetsmessige forhold og relevante tiltak krever derfor omfattende planlegging som nå er påbegynt i IFEs prosjektgruppe. 5.6 IFEs oppfølging. IFE har etablert et prosjekt for å koordinere de ulike tiltakene som nå er påkrevet, og for å sette en struktur som ivaretar både behovet for oppdatert sikkerhetsdokumentasjon, konsekvensanalyser, beredskapstiltak og tiltak for karakterisering av brensel. Prosjektet skal knytte til seg nødvendig kompetanse. IFE er allerede i kontakt med internasjonal ekspertise på området. Alle tiltak av sikkerhetsmessig betydning vil bli vurdert av IFEs Sikkerhetskomité. 6 Konklusjon I sitt arbeid for ivaretakelse av sikkerhet for brukt brensel, arbeider IFE for å vedlikeholde de tre grunnleggende kontrollfunksjonen: kjøling, sub-kritikalitet og innkapsling av radioaktive stoffer. Ved å påse at disse tre basisfunksjonene er sikret, ivaretas samtidig sikkerheten til anlegget og dermed allmennheten. Avdeling NMAT har, blant annet etter anbefalinger fra Teknisk Utvalg og Strandenutvalget, gjennomført undersøkelser av brenselselementer fra JEEP Is første brenselsladning fra 1951 og av HBWRs første brenselsladning fra Den overordnete konklusjonen er at de synlige delene av de fem elementene fra HBWR har tett kapsling. Videre at det ene elementet fra JEEP I har defekter som har mindre betydning for kapslingens tetthet, og at kapslingen er tett på det stedet brenselet er nærmere undersøkt. Det ble observert brune og hvite felt på aluminiumskapslingen, svellinger/

16 14 blemmer, sprekkdannelse og noe deformering. Årsaken til blemmer på brensel fra JEEP I stavbrønn er lokal korrosjon/ hydrering. Dette indikerer at det har vært vann eller hydrogen tilgjengelig for reaksjon med brenslet, sannsynligvis som følge av fukt fra produksjon, bestråling og/ eller tidlig lagring. Stikkprøver fra tørrlageret i Halden (HBWR-bunker) med brukt brensel fra HBWR første lastning viser på sin side ingen blemmer og dermed ingen direkte antydning til uranhydriddannelse. Undersøkelsene bekrefter dermed at korrosjonsproduktene i aluminiumkapslet, metallisk brensel med dårlig lagringsbestandighet, beskrevet generelt i tidligere i offentlige utredninger, også er observert i brenselet i IFEs statiske lagre for historisk brensel. Sentrale forhold ved det brukte brenslet og lagrenes tilstand tilsier at den overordnete risikoen for hendelser er lav, blant annet fordi at lagrene inneholder flere barrierer mot utslipp og inntrengning av vann. Det vurderes som lite sannsynlig at det vil oppstå reaksjoner i det lagrete brenslet som kan medføre utslipp til luft og vann. Det er sannsynlig at de forandringene som er synlige i dag, oppsto tidlig og at utviklingen går sakte eller har stoppet opp. Dette understreker at det er liten risiko for særlige hendelser i tilknytning til lageret. Håndteringen av brenselet ved JEEP I stavbrønn og HBWR bør begrenses før mer detaljerte risikovurderinger gjennomføres. Funnene fra det undersøkte brenselet i JEEP I stavbrønn gjør det nødvendig med intensivert overvåkning og registrering av status og utvikling. IFE har i sin høringsuttalelse til Strandenutvalgets utredning sagt at det er sentralt at tidsplanen som ble foreslått av Utvalget. foreslått av utvalget følges Undersøkelsene av brenselet understreker betydningen av dette.

17 15 7 Referanser 1 Technical Committee, «Recommendations for the Conditioning of Spent Metallic Uranium Fuel and Aluminium Clad Fuel for Interim Storage and Disposal», A report prepared by the Technical Committee on Storage and Disposal of Metallic Uranium Fuel and Al-clad Fuels for Nærings- og handelsdepartementet, januar NOU 2011: 2 «Mellomlagerløsning for brukt reaktorbrensel og langlivet mellomaktivt avfall» (Strandenutvalget), januar Institutt for Energiteknikk, Sikkerhetsrapport for lagrene for bestrålt brensel på Kjeller (KD /KP ), desember Institutt for Energiteknikk, Sikkerhetsrapport for Haldenreaktoren, desember Helsedepartementet, Konsesjon for drift av IFEs atomanlegg, november NOU 2001: 30, «Vurdering av strategier for sluttlagring av høyaktivt reaktorbrensel», (Berganutvalget), desember 2001 (webtilgang 1. februar, 2013: 7 Fase 1 utvalget, «Etablering av nytt mellomlager for høyaktivt avfall, Lagringsbehov, alternative tekniske løsninger og momenter for valg av teknisk løsning og lokalisering», Utredning gjennomført av Fase 1 - utvalget i perioden januar juni 2004 på oppdrag fra Nærings- og handelsdepartementet, juni 2004 (webtilgang 1. februar, 2013: mellomlagerrapportjuli04.pdf). 8 Institutt for Energiteknikk, Søknad om konsesjon for videre drift av Institutt for energiteknikks konsesjonsunderlagte atomanlegg etter 2008, desember Statens strålevern, Høring NOU 2011:2 Utredning av mellomlagerløsning for brukt reaktorbrensel og langlivet mellomaktivt avfall, 30. september IFE, Høringsuttalelse Mellomlagerløsning for brukt reaktorbrensel og langlivet mellomaktivt avfall (NOU 2011:2) (brev), 26. september Technical Information Service, Atomic Energy Commission, The Industrial Atom The Fire Properties of Metallic Uranium, April 12, F. Le Guyadec et al, «Pyrophoric behaviour of uranium hydride and uranium powders», Journal of Nuclear Materials 396 (2010), pp , M- Epstein and B. Malinovic, Uranium Pyrophoricity Phenomenia and Prediction, SNF-6192-FP 2004 (webtilgang 1. februar, 2013: UraniumPyrophoricityPhenomenaandPrediction.pdf). 14 I. Bjørner et al., «Behandling av korrodert R1-brensel ved Forvaringsanlegningen i Studsvik Steg 1 Sikkerhetsrapport», mai 1990.

18 16 8 Vedlegg. A1 A2 A3 A4 A5 A6 A7 V. Andersson, B. C. Oberländer, «HBWR 1st charge fuel- visual inspection & gamma scanning, IFE/KR/F-2012/110 (unntatt offentlighet, jf. atomenergiloven 53). V. Andersson, B. C. Oberländer, H. K. Jenssen, H. J. Kleemann, «Investigation of one fuel element from JEEP I 1st charge from 1951», IFE/KR/F-2012/111 (unntatt offentlighet, jf. atomenergiloven 53). T. A. Gulbrandsen, Kardex-kort fra 1. lastning HBWR. Avd. REAK, samt oversikt over elementer som er reprosessert ved Kjeller (unntatt offentlighet, jf. atomenergiloven 53). E. Lundby, Kartotekkort fra vis.insp. av brenselselementene i JEEP 1 stavbrønn. Avd. NMAT (unntatt offentlighet, jf. atomenergiloven 53). IFE, Tegninger av lagrene, historiske brenselselementer, lagringsbeholdere, og annet utstyr for lagring av historisk metallisk uranbrensel i JEEP I stavbrønn og HWBRbunker (unntatt offentlighet, jf. atomenergiloven 53). IFE, Opplisting av lagerbeholdningen i JEEP I «statisk» stavbrønnlager (unntatt offentlighet, jf. atomenergiloven 53). IFE, Lagerbeholdning i «statisk» lager fot brukt brensel - HBWR-bunker (unntatt offentlighet, jf. atomenergiloven 53).

19 Institutt for energiteknikk Postboks 40 NO-2027 Kjeller, Norge Telefon: (+47) Telefax: (+47)

Hva gjør IFE med det historiske atomavfallet?

Hva gjør IFE med det historiske atomavfallet? Ha gjør IFE med det historiske atomafallet? Peter Bennett Prosjektleder Ole Reistad Sikkerhetssjef Presentasjon 10. februar 2016 Kjeller Ha er iktig å ite om det historiske afallet? Ha er historisk afall?

Detaljer

FeInstitutt for energiteknikk

FeInstitutt for energiteknikk FeInstitutt for energiteknikk Nærings og handelsdepartementet Postboks 8014 Dep 0030 Oslo Instituttveien18 Postboks40, NO-2027Kjeller Tlf: +4763806000 Faks: +4763816493 Org.nr.: NO959432538 Web: www.ife.no

Detaljer

SAKSDOKUMENT UTREDNING AV MELLOMLAGERLØSNING FOR BRUKT REAKTORBRENSEL OG LANGLIVET MELLOMAKTIVT AVFALL - HØRING

SAKSDOKUMENT UTREDNING AV MELLOMLAGERLØSNING FOR BRUKT REAKTORBRENSEL OG LANGLIVET MELLOMAKTIVT AVFALL - HØRING SAKSDOKUMENT Arkivsaknr.: 11/02084-2 Arkivkode: 0, M65 Saksbehandler Guro Haug Saksgang Møtedato Komite for miljø- og samfunnsutvikling 22.08.2011 Kommunestyret 29.08.2011 UTREDNING AV MELLOMLAGERLØSNING

Detaljer

Oslo, STRANDEN-UTVALGET: HØRINGSUTTALELSE FRA GREENPEACE

Oslo, STRANDEN-UTVALGET: HØRINGSUTTALELSE FRA GREENPEACE Oslo, 30.09.2011 STRANDEN-UTVALGET: HØRINGSUTTALELSE FRA GREENPEACE Vi viser til mottatt høringsbrev på NOU 2011:2. Vår uttalelse knytter seg særlig til utvalgets forslag om å sende deler av det norske

Detaljer

NoU: Mellomlagerløsning, brukt kjernebrensel og langlivet mellomaktivt avfall

NoU: Mellomlagerløsning, brukt kjernebrensel og langlivet mellomaktivt avfall NoU: Mellomlagerløsning, brukt kjernebrensel og langlivet mellomaktivt avfall Sammensetning av utvalget Medlemmer Erling Stranden, professor, Kongsberg (leder) Arne Bjørlykke, direktør, Oslo Rolf Jullum,

Detaljer

HVORFOR HAR VI EN FORSKNINGS- REAKTOR PA KJELLER? Institutt for energiteknikk. Institutt for energiteknikk

HVORFOR HAR VI EN FORSKNINGS- REAKTOR PA KJELLER? Institutt for energiteknikk. Institutt for energiteknikk Rostra Reklamebyrå RRA 26 Foto: Kjell Brustaad Oktober 1998 HVORFOR HAR VI EN FORSKNINGS- REAKTOR PA KJELLER? Institutt for energiteknikk KJELLER: Postboks 40, 2007 Kjeller Telefon 63 80 60 00 Telefax

Detaljer

NOU. Norges offentlige utredninger 2011: 2. Mellomlagerløsning for brukt reaktorbrensel og langlivet mellomaktivt avfall

NOU. Norges offentlige utredninger 2011: 2. Mellomlagerløsning for brukt reaktorbrensel og langlivet mellomaktivt avfall NOU Norges offentlige utredninger 2011: 2 Mellomlagerløsning for brukt reaktorbrensel og langlivet mellomaktivt avfall Norges offentlige utredninger 2011 Seriens redaksjon: Departementenes servicesenter

Detaljer

Statens stråleverns innstilling til konsesjon etter atomenergiloven

Statens stråleverns innstilling til konsesjon etter atomenergiloven Statens strålevern Norwegian Radiation Protection Authonity Statens stråleverns innstilling til konsesjon etter atomenergiloven io Dato: 01.11.2018 Ref: 16/01036 Fra: Til: Statens strålevern Helse- og

Detaljer

Status og fremdrift for arbeidene med opprydning av atomavfallet

Status og fremdrift for arbeidene med opprydning av atomavfallet Status og fremdrift for arbeidene med opprydning a atomafallet / Sektordirektør Henning R. Vahr Halden, 30. august 2017 Oppslag i media 1 Om IFEs nye sektor Atomafall 2 IFEs organisering 01.09.2017 3 IFE

Detaljer

Dato: 30. april 2008 Ref: 2006/00503/520.3 Statens strålevern Helse- og omsorgsdepartementet

Dato: 30. april 2008 Ref: 2006/00503/520.3 Statens strålevern Helse- og omsorgsdepartementet Innstilling Dato: 30. april 2008 Ref: 2006/00503/520.3 Fra: Til: Statens strålevern Helse- og omsorgsdepartementet STATENS STRÅLEVERNS INNSTILLING TIL INSTITUTT FOR ENERGITEKNIKKS SØKNAD OM FORNYET KONSESJON

Detaljer

Stavbrønnen Strålevern og miljøovervåking. Tore Ramsøy Fungerende Strålevernsjef

Stavbrønnen Strålevern og miljøovervåking. Tore Ramsøy Fungerende Strålevernsjef Stabrønnen Stråleern og miljøoeråking Tore Ramsøy Fungerende Stråleernsjef Stabrønn - skisse Beholder Sta Brønn: Rør a sartstål Beholder: Rustfritt stål Brenselssta: Metallisk uran kapslet med ubehandlet

Detaljer

Norsk atomavfall, norsk ansvar

Norsk atomavfall, norsk ansvar Norges Naturvernforbund (NNV), Greenpeace, Verdens Naturfond (WWF), Fremtiden i våre hender (FIVH), Lofoten mot Sellafield, Norges Miljøvernforbund, Nei til Atomvåpen, og Internasjonal kvinneliga for fred

Detaljer

RADIO- AVFALLET SLIK TAR VI HAND OM DET AKTIVE. KJELLER: Postboks 40, 2007 Kjeller Telefon Telefax

RADIO- AVFALLET SLIK TAR VI HAND OM DET AKTIVE. KJELLER: Postboks 40, 2007 Kjeller Telefon Telefax Rostra Reklamebyrå RRA 26 Foto: Kjell Brustaad Okt. 1998 SLIK TAR VI HAND OM DET RADIO- AKTIVE AVFALLET KJELLER: Postboks 40, 2007 Kjeller Telefon 63 80 60 00 Telefax 63 81 63 56 HALDEN: Postboks 173,

Detaljer

Status og fremdrift for arbeidene med opprydding i atomavfallet på Kjeller

Status og fremdrift for arbeidene med opprydding i atomavfallet på Kjeller Status og fremdrift for arbeidene med opprydding i atomafallet på Kjeller / Sektordirektør Henning R. Vahr Kjeller, 22. juni 2017 Oppslag i media 2 Om IFEs nye sektor Atomafall 2 Ife Organisasjonskart

Detaljer

Kapittel 12. Brannkjemi. 12.1 Brannfirkanten

Kapittel 12. Brannkjemi. 12.1 Brannfirkanten Kapittel 12 Brannkjemi I forbrenningssonen til en brann må det være tilstede en riktig blanding av brensel, oksygen og energi. Videre har forskning vist at dersom det skal kunne skje en forbrenning, må

Detaljer

Etablering av nytt mellomlager for høyaktivt avfall

Etablering av nytt mellomlager for høyaktivt avfall Etablering av nytt mellomlager for høyaktivt avfall Lagringsbehov, alternative tekniske løsninger og momenter for valg av teknisk løsning og lokalisering Utredning gjennomført av Fase 1 - utvalget i perioden

Detaljer

1 KVALITETSYSTEM... 3 1.1 IFEs kvalitetssystem... 3 1.2 Rødt nivå... 3 1.3 IFEs kontrollrutiner... 3 1.4 Prosesser... 3

1 KVALITETSYSTEM... 3 1.1 IFEs kvalitetssystem... 3 1.2 Rødt nivå... 3 1.3 IFEs kontrollrutiner... 3 1.4 Prosesser... 3 Dokument ID: SAR 18 Utgave nr.: 1 Konf. grad : Tekst: Åpen, Figurer: Konfidensiell 2 av 6 Innhold 1 KVALITETSYSTEM... 3 1.1 IFEs kvalitetssystem... 3 1.2 Rødt nivå... 3 1.3 IFEs kontrollrutiner... 3 1.4

Detaljer

Spenning Kapasitet (mm) (mm) (g) (V) (mah) PR10-D6A PR70 1,4 75 5,8 3,6 0,3 PR13-D6A PR48 1,4 265 7,9 5,4 0,83 PR312-D6A PR41 1,4 145 7,9 3,6 0,58

Spenning Kapasitet (mm) (mm) (g) (V) (mah) PR10-D6A PR70 1,4 75 5,8 3,6 0,3 PR13-D6A PR48 1,4 265 7,9 5,4 0,83 PR312-D6A PR41 1,4 145 7,9 3,6 0,58 Produkt Zinc Air-batteri Modellnavn IEC Nominell Nominell Diameter Høyde Vekt Spenning Kapasitet (mm) (mm) (g) (V) (mah) PR10-D6A PR70 1,4 75 5,8 3,6 0,3 PR13-D6A PR48 1,4 265 7,9 5,4 0,83 PR312-D6A PR41

Detaljer

Sikkerhetsprinsippene/konseptene i kjernekraftsammenheng

Sikkerhetsprinsippene/konseptene i kjernekraftsammenheng Sikkerhetsprinsippene/konseptene i kjernekraftsammenheng Atle Valseth Mini-konferanse Sikkerhetsaspekter knyttet til kjernekraftanlegg Tekna Oslo 21. januar 2009 IAEAs sikkerhetsprinsipper 1. Sikkerhetsansvaret

Detaljer

(UOFFISIELL OVERSETTELSE)

(UOFFISIELL OVERSETTELSE) NOR/311L0097.tona OJ L 328/2011, p. 49-52 COUNCIL DIRECTIVE 2011/97/EU of 5 December 2011 amending Directive 1999/31/EC as regards specific criteria for the storage of metallic mercury considered as waste

Detaljer

Forhold som skal vurderes under planlegging prosjektering

Forhold som skal vurderes under planlegging prosjektering Forhold som skal vurderes under planlegging prosjektering 1 Risikovurdering av lokalitetene og verdiene som skal sikres. Det må foretas en vurdering av virksomheten som skal sikres, med tanke på mulighetene

Detaljer

Korrosjon. Øivind Husø

Korrosjon. Øivind Husø Korrosjon Øivind Husø 1 Introduksjon Korrosjon er ødeleggelse av materiale ved kjemisk eller elektrokjemisk angrep. Direkte kjemisk angrep kan forekomme på alle materialer, mens elektrokjemisk angrep bare

Detaljer

Godkjent prosjektansvarlig:

Godkjent prosjektansvarlig: Olje & Energi Seksjon for Materialteknologi Porsgrunn MATERIALTEKNISK RAPPORT Gradering: Internt Tittel: Westerns forlis. Sakkyndig uttalelse vedrørende hull i aluminium bakkdekk. Forfatter(e): Håkon Leth-Olsen

Detaljer

Green Rock 05, 05 S1, 05 S2 and 05 S3 Montering/Drift/Vedlikehold

Green Rock 05, 05 S1, 05 S2 and 05 S3 Montering/Drift/Vedlikehold Green Rock 05, 05 S1, 05 S2 and 05 S3 Montering/Drift/Vedlikehold Green Rock 05 er designet for en-familie hus og hytter med relativt lite vannforbruk, og hvor avløpsvannet kan slippes direkte ut i terrenget

Detaljer

HØRING PÅ NOU 2011: 2: MELLOMLAGRINGSLØSNING FOR BRUKT REAKTORBRENSEL OG LANGLIVET MELLOMAKTIVT AVFALL

HØRING PÅ NOU 2011: 2: MELLOMLAGRINGSLØSNING FOR BRUKT REAKTORBRENSEL OG LANGLIVET MELLOMAKTIVT AVFALL 3. oktober 2011 Nærings- og handelsminister Trond Giske Postboks 8014 Dep. 0030 Oslo HØRING PÅ NOU 2011: 2: MELLOMLAGRINGSLØSNING FOR BRUKT REAKTORBRENSEL OG LANGLIVET MELLOMAKTIVT AVFALL Sammendrag 10.

Detaljer

MØTEINNKALLING. Tillegg SAKSLISTE. Saksnr. Arkivsaksnr. Tittel 19/14 14/305 HØRING - KONSEPTVALGUTREDNINGER (KVU) - NUKLEÆRE ANLEGGENE I NORGE

MØTEINNKALLING. Tillegg SAKSLISTE. Saksnr. Arkivsaksnr. Tittel 19/14 14/305 HØRING - KONSEPTVALGUTREDNINGER (KVU) - NUKLEÆRE ANLEGGENE I NORGE Utvalg: FORMANNSKAPET Møtested: Møterom Havnås Møtedato: 08.05.2014 Tid: 09.00 Eventuelt forfall meldes til tlf. 69 68 16 00 Varamedlemmer møter etter nærmere avtale. MØTEINNKALLING Tillegg SAKSLISTE Saksnr.

Detaljer

Norsk nukleær dekommisjonering (NND)

Norsk nukleær dekommisjonering (NND) 1 Norsk nukleær dekommisjonering (NND) Vi tar ansvaret for sikker og kostnadseffektiv håndtering av atomavfall og en styrt avvikling av Norges atomvirksomhet - til beste for fremtidige generasjoner 18.01.2019

Detaljer

Hva skjer på IFE? Sikkerhet og satsing på Kjeller. Informasjonsmøte 26. august 2019 Kjeller

Hva skjer på IFE? Sikkerhet og satsing på Kjeller. Informasjonsmøte 26. august 2019 Kjeller Hva skjer på IFE? Sikkerhet og satsing på Kjeller Informasjonsmøte 26. august 2019 Kjeller 01 Hva skjer på IFE, Nils Morten Huseby, adm dir IFE 02 Informasjon om Norsk Nukleær Dekommisjonering, Martin

Detaljer

Institutt for energiteknikk PB KJELLER

Institutt for energiteknikk PB KJELLER Institutt for energiteknikk PB 40 2027 KJELLER Deres ref Vår ref Dato 17/3513 05.02.19 Statsbudsjettet 2019: Oppdragsbrev til Institutt for energiteknikk 1. Innledning... 1 2. Overordnede utfordringer

Detaljer

IFE: Forskning for en bedre fremtid! Møte med Region Viken, 16. januar 2019 Nils Morten Huseby, adm dir

IFE: Forskning for en bedre fremtid! Møte med Region Viken, 16. januar 2019 Nils Morten Huseby, adm dir IFE: Forskning for en bedre fremtid! Møte med Region Viken, 16. januar 2019 Nils Morten Huseby, adm dir IFE har to viktige samfunnsoppdrag i 2019 Utvikle forskningen innen energi, radiofarmasi, helse og

Detaljer

2005/00794/520.3/1TH Saksbeh. Isabelle Thelin, tlf

2005/00794/520.3/1TH Saksbeh. Isabelle Thelin, tlf \1 -D L. Li Institutt for energiteknikk Postboks 40 2027 KJELLER Statens Norwegian Radiation Protection Authority Deres ref. Vår ref. pl-( 2005/00794/520.3/1TH Saksbeh. Isabelle Thelin, tlf. 67 16 25 37

Detaljer

Konfidensiell grad: Åpen

Konfidensiell grad: Åpen Konfidensiell grad: Åpen Søknad om fornyet konsesjon for JEEP II JEEP I Stavbrønn Metallurgisk laboratorium I Metallurgisk laboratorium II med tilhørende lagre Brenselsinstrumentverksted Rad. avfall 2019

Detaljer

Håper dette sammen med tidligere sendt inn, er nok for og ta søknaden om mellomlagring videre.

Håper dette sammen med tidligere sendt inn, er nok for og ta søknaden om mellomlagring videre. Haualand, Einar Fra: Haualand, Einar Sendt: 10. februar 2015 09:54 Til: Haualand, Einar Emne: VS: SV: Soltin AS - Søknad om tillatelse til mottak og mellomlagring av farlig avfall (stykkgods) Vedlegg:

Detaljer

Erfaringer to år etter ny forskrift om radioaktivt avfall: Har bransjen klart utfordringene?

Erfaringer to år etter ny forskrift om radioaktivt avfall: Har bransjen klart utfordringene? Erfaringer to år etter ny forskrift om radioaktivt avfall: Har bransjen klart utfordringene? Farlig avfallskonferansen 2013 Solveig Dysvik Bergen, 11.09.2013 Radioaktivitet litt «enkel» fysikk! En rekke

Detaljer

HMS og farlig avfall, brannforebygging som en del av hverdagen

HMS og farlig avfall, brannforebygging som en del av hverdagen Hvem og hva er Renor? Renor er en del av det internasjonale byggevarekonsernet HeidelbergCement Group, som har mer enn 50.000 ansatte i mer enn 50 land. Renor samler inn, mottar, sorterer og forbehandler

Detaljer

(51) Int. Cl. 2 G Ol B 7/14. (21) Patenlssknad nr. 760446. (22) Inngill 12.02.76. (23) Løpedag 12.02.76

(51) Int. Cl. 2 G Ol B 7/14. (21) Patenlssknad nr. 760446. (22) Inngill 12.02.76. (23) Løpedag 12.02.76 [B] (11) UTIEGNINGSSKRIFT JVr. 136429 NORGE [NO] STYRET FOR DET INDUSTRIELLE RETTSVERN (51) Int. Cl. 2 G Ol B 7/14 (21) Patenlssknad nr. 760446 (22) Inngill 12.02.76 (23) Løpedag 12.02.76 (41) Ålment tilgjengelig

Detaljer

Rapport etter kontroll ved Veso Vikan

Rapport etter kontroll ved Veso Vikan Rapport etter kontroll ved Veso Vikan Virksomhet Virksomhetens Adresse Veso Vikan Beisvågsveien 107, 7810 Namsos Deltagere fra virksomheten Heiki Olsen, driftsleder teknisk Mari Ann Flasnes Finnanger,

Detaljer

Forskningsdagene 2007 ved HiT : Kjernekraft basert på Thorium

Forskningsdagene 2007 ved HiT : Kjernekraft basert på Thorium Forskningsdagene 2007 ved HiT - 26.9.2007: Kjernekraft basert på Thorium Siv.ing. Knut K.F. Eitrheim Strålevern, OECD Halden Reactor Project, Institutt for Energiteknikk (IFE) Vi skal se på Prinsippet:

Detaljer

KD-HBWR-2012-10.I. Beredskapsplan

KD-HBWR-2012-10.I. Beredskapsplan KD-HBWR-2012-10.I Beredskapsplan Desember 2012 IF Tilgjengelighet Äpen unntatt enkelte Vedlegg til Administrativtvedtak 081 IFE/adm-vedtak-081 Rapporttittel Beredskapsplan for Institutt for energiteknikks

Detaljer

Licon nedfelt konvektor

Licon nedfelt konvektor Monteringsanvisning Licon nedfelt konvektor 1/6 Monteringsanvisning Generelt Produktene skal ikke plasseres i sterke kjemiske miljøer (som f.eks. klor), eller bli vasket med slike kjemikalier. Produktet

Detaljer

Treårig tilstandsrapport for konsesjonsbelagte anlegg ved Institutt for energiteknikk

Treårig tilstandsrapport for konsesjonsbelagte anlegg ved Institutt for energiteknikk Strålevern Rapport 2003:6 Treårig tilstandsrapport for konsesjonsbelagte anlegg ved Institutt for energiteknikk Norwegian Radiation Protection Authority Postboks 55 N-1332 Østerås Norway Referanse: Reistad

Detaljer

Storulykkeforskriften

Storulykkeforskriften Storulykkeforskriften Utkast til mal for sikkerhetsrapport Vibeke Henden Nilssen, DSB Lars Drolshammer, Miljødirektoratet Generelt om sikkerhetsrapport Krav i storulykkeforskriften: 9 Sikkerhetsrapport

Detaljer

Artikkel 4 Unntak Direktivet skal ikke gjelde visse anlegg, farer eller aktiviteter.

Artikkel 4 Unntak Direktivet skal ikke gjelde visse anlegg, farer eller aktiviteter. Dette jobbhjelpemiddelet er ikke en fullstendig kopi av Seveso ll-direktivet. Innholdet har blitt konsolidert for kortfattethet og bør ikke brukes som referanse når det utføres oppgaver relatert til Seveso-samsvar.

Detaljer

Presentasjon Mars 2016

Presentasjon Mars 2016 Presentasjon Mars 2016 Jan Tore Flottorp Vedlikeholdsingeniør Utexaminert fra Horten Ingeniørhøyskole i 1990 Ansatt på Glencore Nikkelverk siden 1996 Da først i Prosjekt avdelingen, men de siste 7 år som

Detaljer

M U L TI C O N S U L T

M U L TI C O N S U L T Grunnva nnstand M U L TI C O N S U L T Multiconsult rapport 102344-4, Supplerende grunnunder søkelser, innledende geotekniske vurderinger i reguleringsfasen, Dampsagtomta, datert 20. oktober 2003 Løvlien

Detaljer

Kjernekraftsikkerhet internasjonalt, sett i lys av ulykken av Fukushima Daiichi kjernekraftverk. Sikkerhetssjef Atle Valseth

Kjernekraftsikkerhet internasjonalt, sett i lys av ulykken av Fukushima Daiichi kjernekraftverk. Sikkerhetssjef Atle Valseth Kjernekraftsikkerhet internasjonalt, sett i lys av ulykken av Fukushima Daiichi kjernekraftverk Sikkerhetssjef Atle Valseth 12.10.2011 Innhold Kort om IFE Kjernekraft og sikkerhet Hva skjedde ved Fukushima

Detaljer

Innledende ROS-analyser for Vervet

Innledende ROS-analyser for Vervet Innledende ROS-analyser for Vervet 1. Innledning Under utredningsprogrammets kapittel E Analyse av konsekvenser for miljø, naturressurser og samfunn, er det et punkt beskrevet som Beredskap. Konsekvenser

Detaljer

Green Rock IISI. 1. Følgende må være ivaretatt ved installasjon:

Green Rock IISI. 1. Følgende må være ivaretatt ved installasjon: Løsningen er IiSi Green Rock Iisi S 6 og Iisi S 10 er avløpsrenseanlegg for hus med inntil 6 eller 10 beboere. Anleggene har innebygget septiktank og er som basis et biologisk renseanlegg. Kombinert med

Detaljer

ORYX Collar FX 330. ORYX, lidenskap for passiv brannsikring

ORYX Collar FX 330. ORYX, lidenskap for passiv brannsikring ORYX Collar FX 330 ORYX, lidenskap for passiv brannsikring Versjon 1.0, 21-03-2016 ORYX er spesialisert i passiv brannsikring for bygninger. Takket være vår kompetanse og store produktspekter tilbyr ORYX

Detaljer

NOU 1991:9. side 1 av 6. Dokumenttype NOU 1991:9 Dokumentdato 1991-03-01 Tittel Utvalgsleder Utgiver

NOU 1991:9. side 1 av 6. Dokumenttype NOU 1991:9 Dokumentdato 1991-03-01 Tittel Utvalgsleder Utgiver Dokumenttype NOU 1991:9 Dokumentdato 1991-03-01 Tittel Utvalgsleder Utgiver Deponi for norsk lav- og middelaktivt atomavfall Kveseth, Kari Olje- og energidepartementet Oppnevnt 1989-10-13 Sider 53 Note

Detaljer

Hallingdal trepellets

Hallingdal trepellets 5. juli 2010 Hallingdal trepellets Fakta silo: Totalt volum: 7.750 m 3 Volum pellets: 3.500 m 3 Diameter silo: Høyde til toppunkt: Vekt tak: 24 m 21 m 27.000 kg Lagringstemperatur: 30 C Fuktighet pellets:

Detaljer

Monteringsanvisning MA 4.A.1

Monteringsanvisning MA 4.A.1 Strålevarmepanelet fordeler Høy varmestrålingseffekt Strålevarmepanelet har en høyere strålingseffekt sammenlignet med standard strålevarmepaneler, dette på grunn av Sabianas pantenterte system. Ved at

Detaljer

Det er to hovedkategorier strålekilder: Ioniserende strålekilder; radioaktive stoffer, røntgenapparater,

Det er to hovedkategorier strålekilder: Ioniserende strålekilder; radioaktive stoffer, røntgenapparater, 11 STRÅLEVERN 109 110 11.1 Strålekilder Det er to hovedkategorier strålekilder: Ioniserende strålekilder; radioaktive stoffer, røntgenapparater, elektronmikroskoper Sterke ikke-ioniserende strålekilder;

Detaljer

rehabilitering av skorstein Monteringsanvisning www.tolmer.no

rehabilitering av skorstein Monteringsanvisning www.tolmer.no rehabilitering av skorstein Monteringsanvisning www.tolmer.no Takk for at du valgte Tolmer s produkter til å oppgradere din skorstein. Hva kreves? Arbeid knyttet til skorsteinsrehabilitering er søknadspliktig

Detaljer

Lagring og transport av trepellets

Lagring og transport av trepellets Lagring og transport av trepellets Trepellets distribueres i hovedsak på tre følgende hovedmåter: Småsekk i størrelsesområdet 10-30 kg. Storsekk i størrelsesområdet fra 400 kg til 1200 kg. Ved større forbruk

Detaljer

Kartlegging av miljøbetingelser i tunneler. Presentasjon av rapporten, av Jon Luke, Norconsult

Kartlegging av miljøbetingelser i tunneler. Presentasjon av rapporten, av Jon Luke, Norconsult Kartlegging av miljøbetingelser i tunneler Presentasjon av rapporten, av Jon Luke, Norconsult Om rapporten Norconsult har gjennomført en undersøkelse av miljøbetingelser i Helltunnelen, Ekebergtunnelen

Detaljer

RFA206 - Tiltak for avfall som det ikke er tillatt å ta imot

RFA206 - Tiltak for avfall som det ikke er tillatt å ta imot RFA206 - Tiltak for avfall som det ikke er tillatt å ta imot Utarbeidet av: RfD Godkjent av: Even Midtun Dato: 01.12.2014 1. HENSIKT MED INSTRUKSEN 1.1 Formål Sikre at farlig avfall som i strid med bestemmelsene

Detaljer

Stavanger kommune. Spesialinspeksjon Betongelementer Øvrige elementer RAPPORT NR: Klubben kai

Stavanger kommune. Spesialinspeksjon Betongelementer Øvrige elementer RAPPORT NR: Klubben kai Betongelementer RAPPORT NR: 58 16 November 2016 Rapport spesialinspeksjon Betongelementer Stålelementer TYPE OBJEKT: Betongkai Kubben kai Konstruksjons nr. K 028 INSPEKSJON UTFØRT PÅ VEGNE AV: RAPPORT

Detaljer

Sameiet Østlia Skog. Internkontrollsystem. Sameiet Østlia Skog versjon

Sameiet Østlia Skog. Internkontrollsystem. Sameiet Østlia Skog versjon Sameiet Østlia Skog Internkontrollsystem 1 Versjoner: Dato Beskrivelse 2017-09-09 Første versjon, oppdatert med rutiner som gjelder for det elektriske anlegget i garasjeanlegg H1 (Hvitmosevn 4). Rutiner

Detaljer

Metall Waterstop type ACE

Metall Waterstop type ACE Metall Waterstop type ACE Tekniske detaljer Contaflexactiv utvendig hjørneløsning contaflex Bentoseal innvendig tettingsmasse hjørneløsning contaflexactiv utvendig hjørneprofil for overgang dekke/vegg

Detaljer

Bruksanvisning Energimåler. PolluCom-E

Bruksanvisning Energimåler. PolluCom-E Varenummer: 130275 Bruksanvisning Energimåler PolluCom-E - 1 - INNHOLDSFORTEGNELSE 1. GENERELT... 3 2. MONTERING AV MÅLEREN... 3 3. MONTERING AV EKSTERN TEMPERATURSENSOR... 4 3.1 MONTERING I FØLERLOMME...

Detaljer

Montering og bruksanvisning.

Montering og bruksanvisning. Renseanlegg PATRONFILTER Fabrikat: GRE AR125 HENGENDE SKIMMER Montering og bruksanvisning. Foretaksregisteret / 1 Følgende følger med i esken ved kjøp av nytt anlegg: NR KODE BESKRIVELSE AR125 AR125S AR125M

Detaljer

Institutt for energiteknikk

Institutt for energiteknikk Institutt for energiteknikk IFE Halden ~ 220 ansatte IFE Kjeller ~ 340 ansatte Nukleær sikkerhet og pålitelighet (NUSP) Menneske Teknologi Organisasjon (MTO) Energi- og Miljøteknologi (EM) (Vind,sol,hydrogen,...)

Detaljer

Vedlikehold av Ex-utstyr

Vedlikehold av Ex-utstyr Vedlikehold av Ex-utstyr IFEA Ex-forum Gardemoen 20.09.2011 Vedlikeholdskonsept iht EN 60079-17 Vedlikeholdsintervall Erfaringer med Ex-utstyr Arne Nossum Ansvarshavende for elektriske anlegg på Statoil

Detaljer

Inspeksjonsrapport Kontrollaksjon farlig avfall Inspeksjon ved Fjellregionen interkommunale avfallsselskap (FIAS)

Inspeksjonsrapport Kontrollaksjon farlig avfall Inspeksjon ved Fjellregionen interkommunale avfallsselskap (FIAS) Fylkesmannen i Hedmark Miljøvernavdelingen, Postboks 4034, 2306 Hamar Vår dato Vår referanse 22.04.2010 2010/2506 Saksbehandler, innvalgstelefon Arkiv nr. Deres referanse Steinar Østlie, 62 55 11 77 472

Detaljer

Vår dato Vår referanse Deres dato Deres referanse 21.jun.17 P.nr. IAS2189 Kathinka Martinsen Arne Instanes, tlf Tlf.

Vår dato Vår referanse Deres dato Deres referanse 21.jun.17 P.nr. IAS2189 Kathinka Martinsen Arne Instanes, tlf Tlf. Notat nr. IPAS 2189-1 Dato: 21.juni 2017 Prosjekt Energiverket, Longyearbyen. Grunnundersøkelser og grunnforhold. Prosjektnr. 2189 Saksbehandler Arne Instanes Kontroll Johanna L. Rongved Antall sider 5

Detaljer

Korrosjon under isolasjon

Korrosjon under isolasjon Korrosjon under isolasjon NDT konferansen 2010 Statoils strategi Inspeksjon eller vedlikehold? Anbefalinger i European Federation of Corrosion Engineers Tor Harry Fauske Leading Advisor Inspection Technology

Detaljer

ORYX Collar FX 330 BRANNMANSJETT

ORYX Collar FX 330 BRANNMANSJETT ORYX Collar FX 330 BRANNMANSJETT MONTERINGSANVISNINGER Versjon 1.1, 15-02-2017 (Norwegian) PRODUKTBESKRIVELSE ORYX Collar FX 330 er en brannmansjett for å lage brannheende gjennomføringer i vegger og gulv.

Detaljer

UNDERSØKTE KONSTRUKSJONER I HEDMARK

UNDERSØKTE KONSTRUKSJONER I HEDMARK 1 UNDERSØKTE KONSTRUKSJONER I HEDMARK Hedmark Konstr. Observerte nettriss Kjerner Sement/alkalier Reaktive bergarter Konstr. Maks riss i kjerner Riss i Riss i Deform./ type Hvor Areal Maks merket VMG Sement

Detaljer

Nissegården AS. TILSYNSRAPPORT NR. 12/ med pålegg og varsel om sanksjon

Nissegården AS. TILSYNSRAPPORT NR. 12/ med pålegg og varsel om sanksjon Nissegården AS TILSYNSRAPPORT NR. 12/2573-20 med pålegg og varsel om sanksjon 2017 Innhold 1 Innledning... 2 2 Metodikk... 2 3 Pålegg... 2 4 Andre forhold... 4 5 Veiledning om nytt regelverk... 5 Dato

Detaljer

- Utarbeidet på oppdrag fra Nærings- og fiskeridepartementet

- Utarbeidet på oppdrag fra Nærings- og fiskeridepartementet KONSEPTVALGUTREDNING Oppbevaring av norsk radioaktivt avfall - Utarbeidet på oppdrag fra Nærings- og fiskeridepartementet Rapport No.: 2014-1329, Rev. 1.0 Dato: 2015-01-27 DNV GL i samarbeid med Quintessa

Detaljer

1 Innledning. 2 Grunnlag. 3 Grunnforhold

1 Innledning. 2 Grunnlag. 3 Grunnforhold 1 Innledning Arkiplan/Asplan Viak utarbeider regulering av området ved Trondheim sentralstasjon hvor det planlegges ny bussterminal, nye boliger og nye kontorlokaler. Multiconsult ASA er engasjert av Arkiplan

Detaljer

UNIVERSITETET I OSLO

UNIVERSITETET I OSLO UNIVERSITETET I OSLO Det matematisk-naturvitenskapelige fakultet Eksamen i: FYS1000 Eksamensdag: 19. august 2016 Tid for eksamen: 9.00-13.00, 4 timer Oppgavesettet er på 6 sider Vedlegg: Formelark (2 sider).

Detaljer

ISO 27001 Syscom brukerforum 2013 Jørn Erik Hornseth og Torbjørn Remmen

ISO 27001 Syscom brukerforum 2013 Jørn Erik Hornseth og Torbjørn Remmen ISO 27001 Syscom brukerforum 2013 Jørn Erik Hornseth og Torbjørn Remmen Informasjonssikkerhet Visjon «Organisasjonen anerkjennes som ledende aktør innen informasjonssikkerhet» Oppdrag «Å designe, implementere,

Detaljer

Søknadsnr.: CURO AS, Industriveien 53, 7080 Heimdal

Søknadsnr.: CURO AS, Industriveien 53, 7080 Heimdal Søknadsnr.: 121478 Søker: Lyng Pro Tech AS Referanse: P121478NO Fullmektig: CURO AS, Industriveien 3, 7080 Heimdal Tittel: Varmeveksler 1 Varmeveksler Den foreliggende oppfinnelsen angår en varmeveksler

Detaljer

DIN PARTNER FOR HYGIENISK LAGRING. reoler og vogner

DIN PARTNER FOR HYGIENISK LAGRING. reoler og vogner DIN PARTNER FOR HYGIENISK LAGRING reoler og vogner REOLER OG VOGNER i aluminium, plast og rustfritt stål ENKELT RENHOLD Renhold koster penger. Alminor System 150 / 250 er utviklet for å møte stadig høyere

Detaljer

Monterings og bruksanvisning til rustfrie rustjebaner av typen TS og TS Scandi

Monterings og bruksanvisning til rustfrie rustjebaner av typen TS og TS Scandi Monterings og bruksanvisning til rustfrie rustjebaner av typen TS og TS Scandi Takk for di tillit. Belønningen vil være et kvalitetsprodukt og tilfredsstillelse av deres barn. Innledning Her får du informasjon

Detaljer

Treårig tilstandsrapport for konsesjonsbelagte anlegg ved Institutt for energiteknikk

Treårig tilstandsrapport for konsesjonsbelagte anlegg ved Institutt for energiteknikk Strålevern Rapport 2006:24 Treårig tilstandsrapport for konsesjonsbelagte anlegg ved Institutt for energiteknikk Norwegian Radiation Protection Authority Postboks 55 N-1332 Østerås Norway Referanse: Statens

Detaljer

ERGOBORD ST - Tekniske data Denne folder skal alltid oppbevares ved produktet!

ERGOBORD ST - Tekniske data Denne folder skal alltid oppbevares ved produktet! ERGOBORD ST - Tekniske data Denne folder skal alltid oppbevares ved produktet! Innholdsfortegnelse: 1. INTRODUKSJON... 3 2. OVERENSSTEMMELSE MED EU-DIREKTIV... 3 3. BRUKSOMRÅDE... 3 4. MONTERING... 3 5.

Detaljer

Anbefaling 022 N / 2007 Harmonisering av mekaniske koplinger

Anbefaling 022 N / 2007 Harmonisering av mekaniske koplinger Anbefaling 022 N / 2007 Harmonisering av mekaniske koplinger Formål Formålet med en harmonisering av mekaniske koplinger og en felles standard på slanger er å øke sikkerheten ved å få til en harmonisering

Detaljer

Drensplate. Stopper fukt. Kapillær brytende. Effektiv drenering. Enkel å montere

Drensplate. Stopper fukt. Kapillær brytende. Effektiv drenering. Enkel å montere Drensplate I s o l e r e n d e d r e n s p l a t e 1 1 4 Stopper fukt Kapillær brytende Effektiv drenering Enkel å montere E n e r g i b e s p a r e n d e b y g g i s o l a s j o n E n d e l a v S u n

Detaljer

IFE/KR/F-2018/xxx. Eksponering av miljøet fra utslipp til vann og luft av radioaktive stoffer fra Yara AS anlegg på Herøya

IFE/KR/F-2018/xxx. Eksponering av miljøet fra utslipp til vann og luft av radioaktive stoffer fra Yara AS anlegg på Herøya IFE/KR/F-2018/xxx Eksponering av miljøet fra utslipp til vann og luft av radioaktive stoffer fra Yara AS anlegg på Herøya Rapportnummer Tilgjengelighet Revisjonsnummer Dato IFE/KR/F-2018/xxx KONFIDENSIELL

Detaljer

Monterings og bruksanvisning til rustfrie rustjebaner av typen DPP og Basic

Monterings og bruksanvisning til rustfrie rustjebaner av typen DPP og Basic Monterings og bruksanvisning til rustfrie rustjebaner av typen DPP og Basic Takk for di tillit. Belønningen vil være et kvalitetsprodukt og tilfredsstillelse av deres barn. Innledning Her får du informasjon

Detaljer

Miljøet har godt av at du oppgraderer din skorstein. Rehabilitering av skorstein

Miljøet har godt av at du oppgraderer din skorstein. Rehabilitering av skorstein Miljøet har godt av at du oppgraderer din skorstein Rehabilitering av skorstein Tolmer AS har i dag 2 typer rustfrie/ syrefaste stålrør. Vi har stive og flexible stålrør i flere dimensjoner. Produkter

Detaljer

- Kinetisk og potensiell energi Kinetisk energi: Bevegelses energi. Kinetiske energi er avhengig av masse og fart. E kin = ½ mv 2

- Kinetisk og potensiell energi Kinetisk energi: Bevegelses energi. Kinetiske energi er avhengig av masse og fart. E kin = ½ mv 2 Kapittel 6 Termokjemi (repetisjon 1 23.10.03) 1. Energi - Definisjon Energi: Evnen til å utføre arbeid eller produsere varme Energi kan ikke bli dannet eller ødelagt, bare overført mellom ulike former

Detaljer

Til våre naboer INFORMASJON OM SIKKERHET OG BEREDSKAP VED NORDIC PAPER GREÅKER

Til våre naboer INFORMASJON OM SIKKERHET OG BEREDSKAP VED NORDIC PAPER GREÅKER Til våre naboer INFORMASJON OM SIKKERHET OG BEREDSKAP VED NORDIC PAPER GREÅKER 0 Til våre naboer Dette er sikkerhets- og beredskapsinformasjon til våre naboer. Dokumentet gir en beskrivelse av risikobildet

Detaljer

Nedre Berglia garasjer Vedlegg 4, armeringskorrosjon i betong s. 1/5

Nedre Berglia garasjer Vedlegg 4, armeringskorrosjon i betong s. 1/5 Nedre Berglia garasjer Vedlegg 4, armeringskorrosjon i betong s. 1/5 Armeringskorrosjon i betong HVA ER BETONG OG HVORFOR BRUKES ARMERING Betong består av hovedkomponentene: Sand / stein Sement Vann Når

Detaljer

1 RIGGPLAN ORGANISASJONSKART FREMDRIFTSPLAN FORHÅNDSMELDING SAMORDNINGSSKJEMA...4

1 RIGGPLAN ORGANISASJONSKART FREMDRIFTSPLAN FORHÅNDSMELDING SAMORDNINGSSKJEMA...4 Innholdsfortegnelse 1 RIGGPLAN...3 2 ORGANISASJONSKART...3 3 FREMDRIFTSPLAN...4 4 FORHÅNDSMELDING...4 5 SAMORDNINGSSKJEMA...4 6 RISIKOMOMENTER OG SPESIFIKKE TILTAK...4 7 RUTINER FOR AVVIKSBEHANDLING...5

Detaljer

Brannstopp pakning. Brannstopp for brennbare rør 50 mm til 160 mm diameter med pakninger i prekuttede lengder med Europeisk Teknisk Godkjenning

Brannstopp pakning. Brannstopp for brennbare rør 50 mm til 160 mm diameter med pakninger i prekuttede lengder med Europeisk Teknisk Godkjenning Brannstopp pakning Brannstopp for brennbare rør 50 til 160 diameter med pakninger i prekuttede lengder med Europeisk Teknisk Godkjenning Bruksområde Tette rundt brennbare rør 50 to 160 diameter i gjennomføringer

Detaljer

Barrierestyring. Hermann Steen Wiencke PREPARED.

Barrierestyring. Hermann Steen Wiencke PREPARED. Barrierestyring Hermann Steen Wiencke PREPARED. Bakgrunn - Ptil Det overordnede fokuset er at barrierer skal ivaretas på en helhetlig og konsistent måte slik at risiko for storulykker reduseres så langt

Detaljer

Garantert radonsikkert bygg!

Garantert radonsikkert bygg! Garantert radonsikkert bygg! Siden oppstarten i 2009 har Radonmannen AS utviklet seg til å bli ledende i Norge innenfor leveranse av forebyggende tiltak mot radon i nye bygg. Kundegruppen består hovedsakelig

Detaljer

Ski kommune. Le-66. Saksbehandler: Anita M rmæl BEHANDLING: SAKNR Formannskapet 47/11 Kommunestyret DATO 07.09.2011 21.09.2011

Ski kommune. Le-66. Saksbehandler: Anita M rmæl BEHANDLING: SAKNR Formannskapet 47/11 Kommunestyret DATO 07.09.2011 21.09.2011 Ski kommune Le-66 0ø, lar Saksbehandler: Anita M rmæl BEHANDLING: SAKNR Formannskapet 47/11 Kommunestyret Arknr.: M67 Arkivsak: 11/1193-2 DATO 07.09.2011 21.09.2011 HØRING AV UTREDNING OM MELLOMLAGERLØSNING

Detaljer

Antall sider i rapporten: 7 23.10.90 Bransjenr. (NACE-koder): 24.15 Forrige kontroll: 24.04.01 Revisjon

Antall sider i rapporten: 7 23.10.90 Bransjenr. (NACE-koder): 24.15 Forrige kontroll: 24.04.01 Revisjon 1 Rapport nr.: 05.019 (endelig) Virksomhet: Yara Norge AS Bedriftsnummer: 974285150 Virksomhetens adresse: EMAS-registrert: Postboks 190 8161 Glomfjord SFTs arkivkode: Anleggsnummer: 2002 / 1078 A21036

Detaljer

NOTAT. 1 Innledning. 2 Utførelse av fase 1 undersøkelsen SAMMENDRAG

NOTAT. 1 Innledning. 2 Utførelse av fase 1 undersøkelsen SAMMENDRAG NOTAT OPPDRAG Bårliskogen bofellesskap - forprosjekt DOKUMENTKODE 127454-RIGm-NOT-001 EMNE TILGJENGELIGHET Åpen OPPDRAGSGIVER HR Prosjekt AS OPPDRAGSLEDER Gunnar Brønstad KONTAKTPERSON Leif Kirkholm SAKSBEHANDLER

Detaljer

Innst. S. nr Innstilling fra energi- og miljøkomiteen om videreføring av Haldenprosjektet. St.meld. nr. 22 ( ). SAMMENDRAG ( )

Innst. S. nr Innstilling fra energi- og miljøkomiteen om videreføring av Haldenprosjektet. St.meld. nr. 22 ( ). SAMMENDRAG ( ) Innst. S. nr. 126. (1998-99) Innstilling fra energi- og miljøkomiteen om videreføring av Haldenprosjektet. St.meld. nr. 22 (1998-99). Til Stortinget. SAMMENDRAG Formålet med meldingen er å presentere Regjeringens

Detaljer

Installasjon av glassfiberbasseng.

Installasjon av glassfiberbasseng. Installasjon av glassfiberbasseng. Valg av plassering: Tenk nøye igjennom plasseringen av bassenget før du begynner: - I forhold til naboer/sjenanse. - Innsyn. - Nærhet til løvfellende trær - Solforhold

Detaljer

!"#"$%&# '&()*"$$+,-,$"(+.&%+/0)1**2%+30##$"$$1#4+ &4+5",/-$$"*,"+03+5"$&#4

!#$%&# '&()*$$+,-,$(+.&%+/0)1**2%+30##$$$1#4+ &4+5,/-$$*,+03+5$&#4 !"#"$%&# '&()*"$$+,-,$"(+.&%+/0)1**2%+30##$"$$1#4+ &4+5",/-$$"*,"+03+5"$&#4 678+9:+!9;9 PENETRON er en kjemisk behandling for kapillær vanntetting av betong. PENETRON er et tørt pulver som består

Detaljer

Manger kirke RAPPORT. Radøy sokneråd. Vurdering av forsterkningsløsning 615689-RIB-RAP-001 OPPDRAGSGIVER EMNE

Manger kirke RAPPORT. Radøy sokneråd. Vurdering av forsterkningsløsning 615689-RIB-RAP-001 OPPDRAGSGIVER EMNE RAPPORT Manger kirke OPPDRAGSGIVER Radøy sokneråd EMNE DATO / REVISJON: 18. desember 2014 / 0 DOKUMENTKODE: 615689-RIB-RAP-001 Denne rapporten er utarbeidet av Multiconsult i egen regi eller på oppdrag

Detaljer

ELEKTRO PULS TEKNOLOGIER AS. SPESIALISTER I FLYTTING AV VÆSKER I KAPILLÆRER Og. Elektro- Osmose. Pilotprosjekt no 2.

ELEKTRO PULS TEKNOLOGIER AS. SPESIALISTER I FLYTTING AV VÆSKER I KAPILLÆRER Og. Elektro- Osmose. Pilotprosjekt no 2. Og Elektro- Osmose Pilotprosjekt no 2 Nummer: P-01-060-R Gjennomført av IKM Laboratorium AS I samarbeid med Elektro Puls Teknolier as. Formåler med denne installasjon av EPS Systemet er å kunne garantere

Detaljer