Original instructions. SIRe Basic Fan Heaters Electric With quick guide. SIReBX. For wiring diagram, please see last pages.

Like dokumenter
Original instructions. SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see last pages

Original instructions. SIRe Basic Fan Heaters Water With quick guide. SIReB. For wiring diagram, please see last pages.

Original instructions. SIRe Basic Air Curtains Water With quick guide. SIReB. For wiring diagram, please see last pages

SIRe Basic Fan Heaters Water With quick guide SIReB

Original instructions. SIRe Basic Quick guide. SIReB

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

SIRe Competent Fan Heater Electric. SIReFCX. With quick guide. For wiring diagram, please see last pages SE... 2 ES

SIRe Competent Fan heaters Functions. SIReFC

SIRe Advanced Fan Heater Electric. SIReFAX SIReFAEMX. With quick guide GB DE FR For wiring diagram, please see last pages

SIRe Competent Air Curtains Electric With quick guide. SIReAC. For wiring diagram, please see last pages SE... 2 ES

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see last pages SE... 2 ES

Original instructions. SIRe Competent Fan Heater Water With quick guide. SIReFC SE For wiring diagram, please see last pages

SIRe Competent Air Curtains Functions. SIReAC

Styresystem SIRe. Intelligent Tilpasser seg automatisk inngangen. Proaktiv funksjon Gir raskere reaksjon

BRUKS- OG MONTERINGSANVISING FOR CLIVET HID-S1 ELEKTRONISK TERMOSTAT

SIRe Advanced Air Curtains Water Ambient, no heat

SIRe Advanced Fan Heater - Water. SIReFA SIReFAWM. With quick guide GB DE FR For wiring diagram, please see last pages. ES...

ASU-4 alarmsystem. Tekniske data:

SIRe Advanced Air Curtains Functions. SIReAA

SILENCIO EL TERMOSTAT

CTC Trådløs romføler. Funksjon - Drift - Vedlikehold

Teknisk spesifikasjon:

Varmluftsvifte Panther Kraftig varmevifte for store lokaler

CLIVETTALK KONTROLLER CLIVET TALK

Portier. Portier. Elegante luftporter for inngangspartier. 1 Uten varme 3 Elvarme: 3-13,5 kw. Anbefalt installasjonshøyde 2,5 m*

KOMPAKT ReGO Ventilasjonsaggregater styresystem C4 Installasjons- og driftsmanual

Drift og installasjons veiledning DB3 Pumpdrive

SEMPA TERMOBLOK VEGGHENGTE ELEKTROKJELER MONTERINGS- OG BETJENINGSINSTRUKS

DOMEKT ReGO Ventilasjonsaggregater styresystem C4 Installasjons- og driftsmanual

Regulator for elektrokjeler. type:

TA VARE PÅ DENNE INNSTRUKSJONEN BRUKER MANUAL

Styresystem SIRe. Intelligent Tilpasser seg automatisk inngangen. Proaktiv funksjon Gir raskere reaksjon

Elektra V GB NO DE PL

Drift og installasjons veiledning MT10 Styring for 4" pumper

SmartDial. Trådløs. Bruksanvisning. -no. Dokument oversatt fra engelsk A001

Roth Touchline Brukerveiledning

Elektrisk koblingsskjema for regulator T-MB og MB kort på Sabiana fancoiler.

Brukerveiledning fjernkontroll MR-CH01 og MR-CC01

CTC SMS. Funksjon - Drift - Vedlikehold

Varmluftsvifte Panther 6-15 Effektive varmevifte for middels store lokaler.

Uponor SMS-modul for fjerntilgang R-56

Wavin AHC 9000 trådløs romtermostat u/nattsenknig Monteringsveiledning

Elektra H GB... 9 NO

Regulator for elektrokjeler. type:

57692b qxd: /02/09 12:10 Side 1. Type MTD2 med trådløs IR-gulvføler. Norsk

Nå med batteribackup

Varmluftsvifte Cat. Varmluftsvifte Cat. Kompakt varmevifte for små lokaler

BRUKSANVISNING VIFTEOVN VT 2000E

Olimpia Splendid Bi2 BRUKERVEILEDNING. Oslo/Sandvika Tel: Tel: Tel:

ASU-4 alarmsystem. Lad batteriene i minst 12 timer før ASU-4 settes i full drift. Med forbehold om endringer. Nyborg, , BK/HAK.

Varmluftsvifte Elektra

Manual for ASU-10 alarmsentral

AR200 AR200. Innfelt luftport for små innganger. 1 Uten varme 3 Elvarme: 3 18 kw 2 Vannbåren varme. Anbefalt installasjonshøyde 2,5 m*

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 1 Uten varme 3 Elvarme: 8 30 kw 2 Vannbåren varme WL.

Wavin AHC 9000 trådløs romtermostat m/ir gulvføler u/nattsenkning Monteringsveiledning

ASU Monitor inng.: 0= frakoblet, 1= kontakt, 2= temperatur, 3= kont. + temp. 3.

MP2000 Dataromskjøler

Romtermostatens brukerveiledning. For brukeren. Romtermostatens brukerveiledning. geotherm VWL 45/1 VWL 65/1 VWL 75/1 VWL 125/1 VWL 155/1

Disse anvisningene er delt inn i to deler. Først bruksanvisningen og så installasjonsanvisningene nederst i dette dokumentet.

Wireless Clickkit Quickguide

NOVA trådløs regulering

GRAM PLUS/TWIN/EURO /02

Varmluftsvifter SWT. Varmluftsvifter SWT. Takmontert varmevifte med vannbåren varme

Display og knapper 3-4. Flammesymbol 5 Batterier 5 Synkronisering 6 Tid og dato 6. Manuell styring 7-10 Tidsplan 11

Menysystem. Generelt. Navigasjon. CTC Basic display

Bruksanvisning for. Vifteovn. Modell: VS 2000

B r u k e r m a n u a l

MWR-WH00 KABLET FJERNKONTROLL. Brukermanual. Takk for at du kjøpte dette Samsung-produktet. Takk for at du kjøpte dette Samsung-produktet.

Elektra - C/F/V/H Slitesterke varmevifter til svært krevende omgivelser

Varmepumper og skap for varmeanlegg

Lagre disse instruksjonene CZ-RE2C2. Forenklet fjernkontroll for splitt-system-klimaanlegg BRUKSANVISNING

Feilkoder/suport. Rens kondensator med trykkluft/nitrogen, eller vask med fettløsende vaskemiddel Defekt vifte (hvis Sjekk vifte, bytt hvis defekt

Innhold: ISTC-kontroller Oppsett av intelligent styring

Kontrollpanel med WIFI-tilkobling for Arctic Pro varmepumper. Brukermanual

BRUKSANVISNING EASYSTART TIMER MONTERINGSANVISNING BILVARMEAPPARATER TEKNISK DOKUMENTASJON BRUKSANVISNING KORT VEILEDNING

AirPatrol WiFi Versjon 2 Full Manual. for ios V4.2

Bruksanvisning Termostat MSD4-1655

Display og knapper 3-4. Flammesymbol 5 Batterier 5 Synkronisering 6 Tid og dato 6. Manuell styring 7-10 Tidsplan 11

BRUKERVEILEDNING. Fjernkontroll BRC315D7

TRÅDLØS MOTTAKER BT-PR02 RF BT-FR02 RF BT-WR02 RF BT-WR02 H&C RF. BRUKSANVISNING NO Trådløse mottakere 4-5

BRUKERMANUAL. App for Beha smartovn

Brynsalléen 4, 0667 Oslo TEL: Fax:

Hurtigveiledning. Les instruksjonene nøye før du bruker apparatet.

Montasjeanvisning for EVR 4 varmluftapparat

/07 (BJ) Type MTC2 / MTD2 med rom- eller gulvføler

MP.com Isvannsaggregat

BRUKERHÅNDBOK. 1 Trykk på Registrer. 2 Angi e-postadresse. 4 Angi brukernavn. 3 Velg land. 7 Bekreft informasjon

Forenklet versjon av installasjons- og bruksanvisning. BRUKERVEILEDNING. Olimpia Splendid Bi2

Varmepumper og skap for varmeanlegg

1 Sikkerhetsinformasjon. 2 Apparatets oppbygning. Persiennestyringssystem. Elektronisk persiennestyring easy Best.-nr. :

110191N CI 50. Monterings-/Brukerveiledning Styrepanel

FDV Fujitsu innedeler for næring.

Varmluftsvifter SWH. Varmluftsvifter SWH. Intelligent varmevifte med ekstremt lavt lydnivå, for vanntilkobling. Produktspesifikasjoner

Brukerveiledning. DEVIreg Touch. Elektronisk intelligent termostat.

Brukerhåndbok for betjeningspanel til: CS275. Versjon 1.0

Installasjon- og Brukerveiledning. VERN Komfyrvakt Sensor. El.nr.: Enkel trygghet

Varmluftsvifte SWX EX

Roth Touchline Brukerveiledning

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 3 Elvarme: 8 30 kw 2 Vannbåren varme WL. For svingdører

Roth Touchline Veiledning til oppsett av system ved kjøling

Transkript:

Original instructions SIRe Basic Fan Heaters Electric With quick guide SIReBX C For wiring diagram, please see last pages.

NO Hurtigveiledning/oppstart Kontroller at alle bestanddeler finnes (se avsnittet Bestanddeler). Råd om plassering Kontrollenheten SIReUB1 har en integrert romtemperaturføler og er montert slik at den er tilgjengelig for brukeren. PC-kortet base SIReB1X er innstallert i nærheten av varmeviften, og kablene mellom PC-kortet base SIReB1X og varmeviften må være 230V. Modulærkablene RJ12 (6p/6c), som fås i forskjellige lengder, brukes til å koble sammen PC-kortet og kontrollenheten. Lengre kabler fås som ekstrautstyr. For maksimale kabellengder se avsnittet Ekstrautstyr. For å unngå at ikke autoriserte personer får tilgang til kontrollenheten kan den eventuelt plasseres et annet sted, og en ekstern romføler, SIReRTX (ekstrautstyr), kan installeres i lokalet for registrering av riktig temperatur. Interngivare SIReIT02 ska monteras i utloppet på värmefläkten i avsedd hållare. Tilkobling av systemet I PC-kort Base SIReB1X kobles apparatet videre med modulærkabel RJ12 (6p/6c) hvis flere apparater skal kobles sammen parallelt. Hvis en ekstern romtemperaturføler SIReRTX benyttes, tilkobles den ved hjelp av modulærkabelen RJ11 (4p/4c) på SIReB1X. PC-kort Base SIReB1X i/ved apparatet og kontrollenhet SIReUB1 tilkobles med modulærkabel RJ12 (6p/6c) etter at de andre apparatene er startet. Strømforsyning for elektrisk varme må tilkobles separat (se håndboken for varmluftsviften). Koblingsskjema Koblingsskjemaene finnes i et eget avsnitt bakerst i denne håndboken. Stille inn ID / Drift uten kontrollenhet Styresystemet kan styre ett eller flere parallellkoblede apparater (maks. 9). Hvert apparat skal ha et unikt ID-nummer (1-9), som stilles inn på PC-kortets ID-velger. For eksempel enhet 1: ID=1, enhet 2: ID=3 Hvis den eksterne styringen av en eller annen grunn ikke er installert, kan apparatet likevel kjøre midlertidig. ID-velgeren settes da til modus 0, se bildet. Funksjonen er halv hastighet og halv varmeeffekt. Ved endring av ID nummer må strømtilførselen frakobles. 2 1 0 3 4 5 Hvert apparat skal ha en unik ID på SIReB1Xkortet. 6 7 2 8 1 9 0 3 4 5 Velg 0 for å kjøre apparatet midlertidig uten ekstern kontroll. 6 7 8 9 11

NO SIRe Basic Fan Heaters Electric Oppstart System forsynt med strøm. Tre sifre 1.4.0. (programvareversjon) vises raskt statusvinduet, etterfulgt av tre horisontale linjer. Etter ca. 30 sekunder vises den gjeldende romtemperaturen i statusvinduet. Etter første oppstart skal følgende grunninnstillinger foretas. Bruk pil opp/ ned til å stille inn ønsket romtemperatur, viftehastighetstrinn og varmetrinn. Du kan endre en innstilling ved å trykke på den runde knappen (bekreft). Innstillingen begynner da å blinke og kan justeres med pil opp/ned. Fabrikkinnstillingene gir manuell vifteregulering og termostatstyrt varme. Flere innstillingsmuligheter finnes i avsnittet Driftsmoduser. Ved første oppstart kan det oppstå alarmer og feilkoder, disse kan vanligvis tilbakestilles uten ytterligere tiltak. Viftetrinn Varmetrinn SE06-15 4 2 SE20 2 2 SE30 2 3 Velg ønsket romtemperatur 5 - +30 C C 20 Velg viftetrinn 1-5 (alt. 1-3) - 3 Aktiver varme 0 = Ingen varme 1 = Varmetrinn 1 mulig 2 = Varmetrinn 2 mulig (3 = Varmetrinn 3 mulig) Varmetrinn styrt av termostat _ 2 12

NO Innhold Hurtigveiledning/oppstart Råd om plassering 11 Tilkobling av systemet 11 Koblingsskjema 11 Stille inn ID / Drift uten kontrollenhet 11 Oppstart 12 Bestanddeler SIReBX 14 Ekstrautstyr 15 Maks. kabellengder 15 Operating modes Driftsmoduser 16 Ettergang vifte 16 Varmeregulering 16 Stille inn verdier 16 System PÅ/AV 16 Kontrollenhet SIReUB1 Oversikt 17 Forklaringer 17 Installatørmeny Parametermeny 18 Parameterbeskrivelse 18 Alarm- og feilkoder Overopphetingsbeskyttelse 19 Visning av alarm og feilkoder 19 Tilbakestilling alarm 19 Koblingsskjema, se siste sider. 13

C NO SIRe Basic Fan Heaters Electric Bestanddeler SIReBX SIReUB1, kontrollenhet Basic Deksel til veggenhet SIReB1X, eksternt PC-kort Basic SIReIT02, intern temperaturføler 2 m SIReCC, modulærkabler Mål bestanddeler Type Beskrivelse HxBxD [mm] L [m] SIReUB1 Kontrollenhet Basic 120x70x35 SIReB1 Integrert PC-kort Base SIRelT Inter temperaturføler 1 SIReCC605 Modulærkabel RJ12 (6/6) 5 14

NO Ekstrautstyr SIReRTX, ekstern romtemperaturføler SIReCJ4, skjøtestykke SIReCJ6, skjøtestykke SIReCC, modulærkabel Type NRF-no. EL-no. Beskrivelse HxBxD [mm] L [m] SIReRTX 85 022 94 Ekstern romtemperaturføler 70x33x23 SIReCJ4 Skjøtestykke for to stk. RJ11 (4/4) SIReCJ6 Skjøtestykke for to stk. RJ12 (6/6) SIReCC603 85 022 95 Modulærkabel RJ12 (6/6) 3 SIReCC605 85 022 96 Modulærkabel RJ12 (6/6) 5 SIReCC610 85 022 97 Modulærkabel RJ12 (6/6) 10 SIReCC615 85 022 98 Modulærkabel RJ12 (6/6) 15 SIReCC403 85 022 99 Modulærkabel RJ11 (4/4) 3 SIReCC405 85 023 01 Modulærkabel RJ11 (4/4) 5 SIReCC410 85 023 02 Modulærkabel RJ11 (4/4) 10 SIReCC415 85 023 03 Modulærkabel RJ11 (4/4) 15 Maks. kabellengder Modulærkabel RJ12 (6p/6c) mellom SIReUB1 og SIReB1(X): maks. 50 m. Modulærkabel RJ12 (6p/6c) mellom to SIReB1(X): maks. 50 m. Modulærkabel RJ11 (4p/4c) til romføler SIReRTX: maks. 20 m. Total kabellengde som tillates i systemet, er maksimalt 300 m. 15

NO SIRe Basic Fan Heaters Electric Driftsmodus Driftsmoduser Fabrikkinnstillingene gir manuell vifteregulering og termostatstyrt varme ved valgt trinn. Viftetrinn SE06-15 4 2 SE20 2 2 SE30 2 3 Varmetrinn Stille inn verdier Bruk pil opp/ned til å velge ønsket romtemperatur, viftehastighetstrinn og varmetrinn. Trykk på bekreftknappen. Tallet/tallene begynner å blinke. Verdien kan nå justeres med pil opp/ned og bekreftknappen. Automodus Endre parameter P04 fra 0 til 1 (se parameterliste på neste side) for å aktivere automodus. Termostaten regulerer både vifte og varme C Manuell drift Senk temperaturinnstillingen under 5 C. Følgende symboler vises i statusvinduet = manuell modus. I manuell modus reguleres både vifte- og varmetrinn manuelt. Temperatur Viftehastighetstrinn 20-3 Varmetrinn _ 2 Ettergang vifte Når varmen er aktivert, fortsetter viften å kjøre for å kjøle ned apparatet. Ettergangstiden er 180 sekunder eller kortere hvis interntemperaturen har falt under +30 C (gjelder bare for apparater med intern temperaturføler). Varmeregulering Når romtemperaturen faller under innstilt temperaturverdi, aktiveres første varmetrinn. Hvis temperaturen fortsetter å falle, aktiveres enda et varmetrinn (se beskrivelsen under parameterne P.00). System PÅ/AV Trykk på PÅ/AV-knappen i 2 sekunder for å slå av systemet. Enhetens sikkerhetsfunksjoner er fortsatt aktive etter at systemet er slått av, som betyr at viften kan fortsette å kjøre en stund etter at AV-modus er valgt. 16

NO Kontrollenhet SIReUB1 Oversikt Pil opp blar oppover C Statusvindu Bekreft Gjeldende romtemperatur 208. Pil ned blar nedover C Ønsket romtemperatur 20 Alarm, rød lysdiode Kjøresignal, grønn lysdiode PÅ/AV-knapp Viftehastighetstrinn - 3 Varmetrinn _ 2 Forklaringer Statusvindu Statusvinduet har fire hovedvisninger: gjeldende og ønsket romtemperatur, vifte- og varmetrinn. Alarmkoder og parameterinnstillinger kan også vises i statusvinduet. Pil opp Bla opp i menyen / øke en innstilling. Bekreft Gir tilgang til installatørmenyen, til å velge parametere og bekrefte en justert innstilling. Etter ca. 20 sekunder går kontrollenheten tilbake til å vise gjeldende temperatur. Pil ned Bla ned i menyen / redusere en innstilling. 17

NO SIRe Basic Fan Heaters Electric Installatørmeny Parametermeny Hold bekreftknappen inne til P00 vises i statusvinduet. Bruk pil opp/pil ned til å bla mellom parameterne. Trykk en gang på bekreftknappen for å endre en innstilling på parametermenyen. Blinkende verdier kan justeres med pil opp/ned og bekreftknappen. Hold bekreftknappen inne for å komme tilbake til statusvinduet. (Statusvinduet vises automatisk på nytt etter ca. 50 sekunder.) P00. P01. P02. P02.. Parameterbeskrivelse P13. P.00 Temperaturforskjell varmetrinn Stiller inn forskjellen mellom varmetrinnene. En fabrikkinnstilling på 1,0 og en ønsket romtemperatur på 20 C gir følgende funksjon: Lavt varmetrinn kobles til ved +19,5 C (kobles fra ved +20,0 C). Hvis temperaturen fortsetter å falle under +18,5 C, tilkobles enda et varmetrinn (kobles fra ved +19,0 C) osv. P.01 Overopphetingsalarm PÅ/AV Mulighet til å blokkere alarmen (gyldig bare for apparater med intern temperaturføler). P.02 Ettergangstid Tid der viften fortsetter å kjøre når varmen er aktivert (gyldig bare for apparater med intern temperaturføler). P.03 Temperaturgrense for ettergang Ettergangstid avbrytes hvis den interne temperaturen faller under denne innstilte verdien (gyldig bare for apparater med intern temperaturføler). P.04 Vifteregulering Velg manuell (0) eller auto (1), les mer under avsnittet Driftsmodus. P.05 Interntemperatur Gjeldende interntemperatur. Bare toppverdien vises når flere apparater er tilkoblet (gjelder bare for apparater med intern temperaturføler). P.06 - P.13 Kjøretid Kjøretid for vifte- og varmetrinn. Parameterliste Parameternummer Beskrivelse Innstillingsområde Fabrikkinnstilling P.00 Temperaturforskjell mellom varmetrinn 0,5-10 1.0 C P.01 Overopphetingsalarm PÅ/AV PÅ=1; AV=0 1/0 1 P.02 Ettergangstid når varme er aktivert 10-300 180 s P.03 Temperaturgrense for ettergang vifte 10-40 30 C P.04 Vifteregulering: Manuell eller Auto; 0=Manuell, 1 = Auto 0/1 0 P.05 Visning av apparatets interntemp./utblåsn.temp. 0-100 P.06 Kjøretid viftetrinn 1 0-99999 P.07 Kjøretid viftetrinn 2 0-99999 P.08 Kjøretid viftetrinn 3 0-99999 P.09 Kjøretid viftetrinn 4 0-99999 P.10 Kjøretid viftetrinn 5 0-99999 P.11 Kjøretid varmetrinn 1 0-99999 P.12 Kjøretid varmetrinn 2 0-99999 P.13 Kjøretid varmetrinn 1+2 0-99999 18

NO Alarm- og feilkoder Overopphetingsbeskyttelse SE06-15: Overopphetingsvernet skal begrense avtrekkstemperaturen til 70 C. Ved 70 C utkobles et effekttrinn. Hvis temperaturen fortsetter å stige, avbrytes all effekt ved 75 C. Hvis temperaturen likevel fortsetter å stige, for eksempel på grunn av feil på en kontaktor, begynner viften å rotere ved 70 C for å holde temperaturen nede. Samtidig startes en overopphetingsalarm, se Tabell - Alarm. Ved innvendige temperaturer på +80 C kjører viften på maksimal hastighet. Hvis apparatet kjøles ned, aktiveres varmeeffekten igjen. Alarmen blir stående i displayet til kontrollenheten. Hvis apparatet overopphetes to ganger i løpet av en time, må alarmen tilbakestilles før oppvarming kan aktiveres igjen. Viften kjører til alarmen er tilbakestilt. SE20-30: Overopphetingsvernet skal begrense avtrekkstemperaturen til 85 C. Ved 85 C utkobles et effekttrinn. Hvis temperaturen fortsetter å stige, avbrytes all effekt ved 90 C. Hvis temperaturen likevel fortsetter å stige, for eksempel på grunn av feil på en kontaktor, begynner viften å rotere ved 85 C for å holde temperaturen nede. Samtidig startes en overopphetingsalarm, se Tabell - Alarm. Ved innvendige temperaturer på +95 C kjører viften på maksimal hastighet. Hvis apparatet kjøles ned, aktiveres varmeeffekten igjen. Alarmen blir stående i displayet til kontrollenheten. Hvis apparatet overopphetes to ganger i løpet av en time, må alarmen tilbakestilles før oppvarming kan aktiveres igjen. Viften kjører til alarmen er tilbakestilt. NB! Utfør en grundig kontroll ved gjentatte alarmer og overopphetingsalarmer, og kontakt autorisert servicepersonale eller Frico hvis du ikke finner årsaken til feilen. statusvinduet. For alarmfeilkoder se Tabell - neste side. Statusvinduet veksler mellom å vise alarm/feilkode og ID-en til apparatet som forårsaker problemet. Aot. U02. Tilbakestilling alarm NB! Før tilbakestilling må du sjekke at feilen er rettet opp, og at det ikke er noe som hindrer apparatet fra å settes i drift igjen! Når feilen er rettet opp, skal alarmen tilbakestilles i henhold til beskrivelsen nedenfor. Alarmvisningen blir borte hvis du trykker på "feil" knapp, men vises i statusvinduet igjen etter ca. 20 sekunder. Ved første oppstart kan det oppstå alarmer og feilkoder, disse kan vanligvis tilbakestilles uten ytterligere tiltak. Alarmkoden begynner å blinke 3 sekunder Ert. res. Visning av alarm og feilkoder Ved en alarm eller en feil vises alarmen/ feilkoden og apparatet den gjelder for, i 19

NO SIRe Basic Fan Heaters Electric Tabell - Alarm Alarm Årsak Handling A.FA Motor alarm Termobryter er utløst. En eller flere motorer er overopphetet. (Bare apparater med uttrukkede termobrytere.) A.ot Overopphetingsalarm Temperaturen i apparatet har oversteget alarmgrensen for overoppheting. (Gjelder bare for apparater med interntemperatur.) Kontroller at ikke noe sperrer for apparatets luftinntak og -uttak. Når den overopphetede motoren har kjølt seg ned, lukkes termobryteren igjen, og alarmen kan tilbakestilles. Sjekk motorene ved gjentatte alarmer, og bytt ut ødelagte motorer. Kontroller at ikke noe sperrer for apparatets luftinntak og -uttak, funksjonen til den innvendige temperaturføleren. Tabell - Feilkoder Feilkode Årsak Handling E.co Kommunikasjon Kommunikasjon SIReB1X har ikke kontakt med SIReUB1. PC-kort SIReB1X har ingen ID = 0 To eller flere SIReB1X har samme IDnummer En eller flere SIReB1X mangler programmer. E.cF ID-feil To eller flere SIReB1X i systemet har forskjellige programmer. E.rt Romfølerfeil Feil i eller manglende ekstern romføler SIReRTX koblet til SIReB1X. E.It Intern følerfeil Feil på eller manglende føler i apparatet (gjelder bare apparater med intern føler). E.ru Romfølerfeil Feil på intern romføler i kontrollenhet SIReUB1. Kontroller tilkoblingen mellom SIReB1 og SIReUB1. Bytt ut eventuelle modulærkabler. Avbryt strømforsyningen og velg forskjellige ID-numre for alle SIReB1X i systemet. Avbryt strømforsyningen og velg forskjellige ID-numre for alle SIReB1X i systemet. Kontakt Frico for støtte. Kontakt Frico for støtte. Koble alltid fra strømforsyningen ved tilkobling eller frakobling av følere. Kontroller følerens tilkobling. Kontroller følerens tilkobling. Hvis føler mangler, kontakt Frico for støtte. Kontroller tilkoblingene mellom SIReUB1 og SIReB1X. Bytt ut eventuelle modulærkabler. Kontroller om en ekstern føler SIReRTX fungerer. Hvis feilen ikke er rettet opp, må SIReUB1 byttes ut. 20

Connections between SIReB1X and Panther SE06, SE09, SE12 and SE15. L L~ N SIReB1X SE06-15 40

Connections between SIReB1X and Panther SE20 L L~ N SIReB1X SE20 41

Connections between SIReB1X and Panther SE30 L L~ N SIReB1X SE30 42

SIReB1X Pot. Unit ID C2 X5 C1 X4 ROOM X3 N L PE PE N L SIReRTX (optional) SIReUB1 C Wiring diagrams Basic 230V~ 43

Wiring diagram SIRe Basic Fan Heaters Electric Basic parallel SIReB1X Pot. Unit ID Pot. Unit ID SIReRTX SIReB1 Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L~ L PE N L SIReUB1 C SIReB1 Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L~ L PE N L 44