Original instructions. SIRe Basic Fan Heaters Water With quick guide. SIReB. For wiring diagram, please see last pages.



Like dokumenter
Original instructions. SIRe Basic Air Curtains Water With quick guide. SIReB. For wiring diagram, please see last pages

Original instructions. SIRe Basic Fan Heaters Electric With quick guide. SIReBX. For wiring diagram, please see last pages.

Original instructions. SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see last pages

SIRe Basic Fan Heaters Water With quick guide SIReB

Original instructions. SIRe Basic Quick guide. SIReB

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see last pages SE... 2 ES

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

Styresystem SIRe. Intelligent Tilpasser seg automatisk inngangen. Proaktiv funksjon Gir raskere reaksjon

SIRe Competent Fan heaters Functions. SIReFC

Original instructions. SIRe Competent Fan Heater Water With quick guide. SIReFC SE For wiring diagram, please see last pages

SIRe Competent Fan Heater Electric. SIReFCX. With quick guide. For wiring diagram, please see last pages SE... 2 ES

BRUKS- OG MONTERINGSANVISING FOR CLIVET HID-S1 ELEKTRONISK TERMOSTAT

SIRe Competent Air Curtains Electric With quick guide. SIReAC. For wiring diagram, please see last pages SE... 2 ES

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 3 Elvarme: 8 30 kw 2 Vannbåren varme WL. For svingdører

ASU-4 alarmsystem. Tekniske data:

SIRe Competent Air Curtains Functions. SIReAC

AR200 AR200. Innfelt luftport for små innganger. 1 Uten varme 3 Elvarme: 3 18 kw 2 Vannbåren varme. Anbefalt installasjonshøyde 2,5 m*

Teknisk spesifikasjon:

SILENCIO EL TERMOSTAT

SIRe Advanced Fan Heater Electric. SIReFAX SIReFAEMX. With quick guide GB DE FR For wiring diagram, please see last pages

CTC Trådløs romføler. Funksjon - Drift - Vedlikehold

SmartDial. Trådløs. Bruksanvisning. -no. Dokument oversatt fra engelsk A001

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 1 Uten varme 3 Elvarme: 8 30 kw 2 Vannbåren varme WL.

KOMPAKT ReGO Ventilasjonsaggregater styresystem C4 Installasjons- og driftsmanual

Luftporter for energieffektivitet og bedre komfort. Ny intelligent luftportserie PA-serien

Brukerveiledning fjernkontroll MR-CH01 og MR-CC01

SFS SFS. Designluftport for svingdører, med intelligent regulering. 3 Elvarme: 8 23 kw 2 Vannbåren varme WL. For svingdører

Drift og installasjons veiledning DB3 Pumpdrive

DOMEKT ReGO Ventilasjonsaggregater styresystem C4 Installasjons- og driftsmanual

Olimpia Splendid Bi2 BRUKERVEILEDNING. Oslo/Sandvika Tel: Tel: Tel:

CLIVETTALK KONTROLLER CLIVET TALK

Elektrisk koblingsskjema for regulator T-MB og MB kort på Sabiana fancoiler.

Varmluftsvifter SWT. Varmluftsvifter SWT. Takmontert varmevifte med vannbåren varme

t* 3 Lydnivå* 2 [ C] [db(a)]

Varmluftsvifte SW02 Stillegående varmevifte for tilkobling til vann i små bygninger.

TA VARE PÅ DENNE INNSTRUKSJONEN BRUKER MANUAL

Elektra V GB NO DE PL

Styresystem SIRe. Intelligent Tilpasser seg automatisk inngangen. Proaktiv funksjon Gir raskere reaksjon

PA2500 PA2500E. Elegant luftport for inngangspartier, med intelligent regulering. 1 Uten varme 3 Elvarme: 5-16 kw 2 Vannbåren varme

SEMPA TERMOBLOK VEGGHENGTE ELEKTROKJELER MONTERINGS- OG BETJENINGSINSTRUKS

BRUKERVEILEDNING. Fjernkontroll BRC315D7

Varmepumper og skap for varmeanlegg

Display og knapper 3-4. Flammesymbol 5 Batterier 5 Synkronisering 6 Tid og dato 6. Manuell styring 7-10 Tidsplan 11

ASU-4 alarmsystem. Lad batteriene i minst 12 timer før ASU-4 settes i full drift. Med forbehold om endringer. Nyborg, , BK/HAK.

Regulator for elektrokjeler. type:

CTC SMS. Funksjon - Drift - Vedlikehold

AR200 AR200. Innfelt luftport for små innganger. 1 Uten varme 3 Elvarme: 3 18 kw 2 Vannbåren varme. Anbefalt installasjonshøyde 2,5 m*

Menysystem. Generelt. Navigasjon. CTC Basic display

FINGERLESER F-007 BRUKERMANUAL.

Roth Touchline Brukerveiledning

Varmepumper og skap for varmeanlegg

Drift og installasjons veiledning MT10 Styring for 4" pumper

Lagre disse instruksjonene CZ-RE2C2. Forenklet fjernkontroll for splitt-system-klimaanlegg BRUKSANVISNING

Display og knapper 3-4. Flammesymbol 5 Batterier 5 Synkronisering 6 Tid og dato 6. Manuell styring 7-10 Tidsplan 11

Nå med batteribackup

B styring til Olimpia SLS (Smart) viftekonvektorer

110191N CI 50. Monterings-/Brukerveiledning Styrepanel

Varmluftsvifte SWX EX

Disse anvisningene er delt inn i to deler. Først bruksanvisningen og så installasjonsanvisningene nederst i dette dokumentet.

Wireless Clickkit Quickguide

Pakkeinnhold. Ordliste. Powerline Adapter

Reguleringssystem EnergyLogic Touchline Wave

FDV Fujitsu innedeler for næring.

Wavin AHC 9000 trådløs romtermostat u/nattsenknig Monteringsveiledning

57692b qxd: /02/09 12:10 Side 1. Type MTD2 med trådløs IR-gulvføler. Norsk

CI 50. Monterings-/Brukerveiledning Styrepanel

SIRe Advanced Fan Heater - Water. SIReFA SIReFAWM. With quick guide GB DE FR For wiring diagram, please see last pages. ES...

Elektra H GB... 9 NO

Uponor SMS-modul for fjerntilgang R-56

BRUKSANVISNING VIFTEOVN VT 2000E

TYPE INNEDEL: ASHG07LUCA ASHG09LUCA ASHG12LUCA ASHG14LUCA ASHG09LTCA ASHG12LTCA

Portier. Portier. Elegante luftporter for inngangspartier. 1 Uten varme 3 Elvarme: 3-13,5 kw. Anbefalt installasjonshøyde 2,5 m*

SIRe Advanced Air Curtains Functions. SIReAA

Forenklet versjon av installasjons- og bruksanvisning. BRUKERVEILEDNING. Olimpia Splendid Bi2

Vannregulering VOS. Se vår hjemmeside eller kontakt oss i Frico for mer informasjon om våre ventilpakker. TBVC SD230 AV.

/07 (BJ) Type MTC2 / MTD2 med rom- eller gulvføler

EGM-100A SERVOMOTOR. Vær oppmerksom!

Monteringsanvisning MA 4.P.3

Spjeldmotor EGM-100A. For wiretrekk. Nominell trekkraft. Ekstern styrestrømssikring Maks. vandring av trommel. Inngangsmotstand

ASU Monitor inng.: 0= frakoblet, 1= kontakt, 2= temperatur, 3= kont. + temp. 3.

Innhold: ISTC-kontroller Oppsett av intelligent styring

SIRe Basic, SIRe Competent. VOSP, trykkuavhengig ventilpakke on/off Komplett sett med toveis trykkuavhengig regulerings- og

MP2000 Dataromskjøler

MWR-WH00 KABLET FJERNKONTROLL. Brukermanual. Takk for at du kjøpte dette Samsung-produktet. Takk for at du kjøpte dette Samsung-produktet.

Bruksanvisning for. Vifteovn. Modell: VS 2000

Installasjon. Shuntautomatikk BAS FORENKLET MONTERING. Monteres på vegg eller felles inn i kjelens panel, der hvor det er tilrettelagt for det.

Brukerhåndbok for betjeningspanel til: CS275. Versjon 1.0

Varmluftsvifte SWTM. Varmluftsvifte SWTM. Takmontert varmevifte i rustbeskyttet utførelse med vannbåren varme. Produktspesifikasjoner

B r u k e r m a n u a l

Hyundai Artful fjernkontroll

Manual for ASU-10 alarmsentral

Bruksanvisning for Bistrot Snack 434 og 464

BRUKER INSTRUKS. For fan coil type FCX - U.

Brukerveiledning for GSMG

BYGGTØRKER-/VARMEVIFTE

BRUKSANVISNING EASYSTART TIMER MONTERINGSANVISNING BILVARMEAPPARATER TEKNISK DOKUMENTASJON BRUKSANVISNING KORT VEILEDNING

Meaco Vifte Instruksjonsmanual

Styringsautomatikk for varmekabler på tak, i nedløp og i takrenner Brukermanual, revisjon 04 (Produsent NOR-IDE AS,

SIRe Advanced Air Curtains Water Ambient, no heat

AGS5000 AGS5000. Luftport for dør/port i industrilokaler og store lokaler, med intelligent styresystem. 1 Uten varme 2 Vannbåren varme WH, WL

Transkript:

Original instructions SIRe Basic Fan Heaters Water With quick guide SIReB C For wiring diagram, please see last pages.

NO Hurtigveiledning/oppstart Kontroller at alle bestanddeler finnes (se avsnittet Bestanddeler). Råd om plassering Kontrollenheten SIReUB1 har en integrert romtemperaturføler og er montert slik at den er tilgjengelig for brukeren. Modulærkablene RJ12 (6p/6c), som fås i forskjellige lengder, brukes til å koble sammen PC-kortet og kontrollenheten. Lengre kabler fås som ekstrautstyr. For maksimale kabellengder se avsnittet Ekstrautstyr. For å unngå at ikke autoriserte personer får tilgang til kontrollenheten kan den eventuelt plasseres et annet sted, og en ekstern romføler, SIReRTX (ekstrautstyr), kan installeres i lokalet for registrering av riktig temperatur. Tilkobling av systemet I PC-kort Base SIReB1(X) kobles apparatet videre med modulærkabel RJ12 (6p/6c) hvis flere apparater skal kobles sammen parallelt. Hvis en ekstern romtemperaturføler SIReRTX benyttes, kobles den til ved hjelp av modulærkabelen RJ11 (4p/4c) på SIReB1(X). Ventilmotoren er koblet til PC-kortet Base SIReB1 (X) PC-kort Base SIReB1(X) i/ved apparatet og kontrollenhet SIReUB1 tilkobles med modulærkabel RJ12 (6p/6c) etter at de andre apparatene er startet. Ved faste installasjoner skal medfølgende kabel og støpsel fjernes. Utfør installasjonen i samsvar med gjeldende forskrifter. apparat skal ha et unikt ID-nummer (1-9), som stilles inn på PC-kortets ID-velger. For eksempel enhet 1: ID=1, enhet 2: ID=3 Hvis den eksterne styringen av en eller annen grunn ikke er installert, kan apparatet likevel kjøre midlertidig. ID-velgeren settes da til modus 0, se bildet. Funksjonen er halv hastighet og varmeeffekt på. Ved endring av ID nummer må strømtilførselen frakobles. 2 1 0 3 4 5 Hvert apparat skal ha en unik ID på SIReB1X-kortet. Oppstart 6 7 2 8 1 9 0 3 4 5 6 7 8 9 Velg 0 for å kjøre apparatet midlertidig uten ekstern kontroll. System forsynt med strøm. Tre sifre 1.4.0. (programvareversjon) vises raskt statusvinduet, etterfulgt av tre horisontale linjer. Etter ca. 30 sekunder vises den gjeldende romtemperaturen i statusvinduet. Bruk pil opp/ned til å stille inn ønsket romtemperatur, viftehastighetstrinn og varmetrinn. Du kan endre en innstilling ved å trykke på den runde knappen (bekreft). Innstillingen begynner da å blinke og kan justeres med pil opp/ned.fabrikkinnstillingene gir manuell vifteregulering og termostatstyrt varme. Flere innstillingsmuligheter finnes i avsnittet Driftsmoduser. Ved første oppstart kan det oppstå alarmer og feilkoder, disse kan vanligvis tilbakestilles uten ytterligere tiltak. Koblingsskjema Koblingsskjemaene finnes i et eget avsnitt bakerst i denne håndboken. Når eksternt PC-kort Base SIReB1X benyttes, skal det trekkes ledninger mellom PC-kortet Base og luftporten. Se egen håndbok for SIReB1X. Stille inn ID / Drift uten kontrollenhet Styresystemet kan styre ett eller flere parallellkoblede apparater (maks. 9). Hvert Velg ønsket romtemperatur 5 - +30 C Velg viftetrinn 1-5 (alt. 1-3) Aktiver varme 0 = Ingen varme 1 = Varmetrinn 1 mulig 2 = Varmetrinn 2 mulig (3 = Varmetrinn 3 mulig) Varmetrinn styrt av termostat C 20-3 _ 1 12

Innhold Hurtigveiledning/oppstart Råd om plassering 12 Tilkobling av systemet 12 Koblingsskjema 12 Stille inn ID / Drift uten kontrollenhet 12 Oppstart 12 Bestanddeler SIReB 14 Ekstrautstyr 15 Maks. kabellengder 15 Vannregulering - ventilsett 16 Driftsmodus Driftsmoduser 17 Automodus 17 Ettergang vifte 17 Stille inn verdier 17 System PÅ/AV 17 Kontrollenhet SIReUB1 Oversikt 18 Forklaringer 18 Installatørmeny Parametermeny 19 Parameterbeskrivelse 19 Alarm- og feilkoder Overopphetingsvern 20 Visning av alarm og feilkoder 20 Tilbakestilling alarm 20 NO Koblingsskjema, se siste sider. 13

C X4 C1 X3 NO Bestanddeler SIReB Integrert i varmluftsviften X5 C2 ROOM PE N L SUPPLY 230V ACTUATOR 230V SIReUB1, kontrollenhet Basic Deksel til veggenhet SIReB1, integrert PC-kort Base SIReIT, intern temperaturføler SIReCC, modulærkabel Mål bestanddeler Type Beskrivelse HxBxD [mm] L [m] SIReUB1 Kontrollenhet Basic 120x70x35 SIReB1 Integrert PC-kort Base SIRelT Inter temperaturføler 1 SIReCC605 Modulærkabel RJ12 (6/6) 5 14

NO Ekstrautstyr SIReRTX, ekstern romtemperaturføler SIReCJ4, skjøtestykke SIReCJ6, skjøtestykke SIReCC, modulærkabel Type NRF-no. EL-no. Beskrivelse HxBxD [mm] L [m] SIReRTX 85 022 94 Ekstern romtemperaturfølerr 70x33x23 SIReCJ4 Skjøtestykke for to stk. RJ11 (4/4) SIReCJ6 Skjøtestykke for to stk. RJ12 (6/6) SIReCC603 85 022 95 Modulærkabel RJ12 (6/6) 3 SIReCC605 85 022 96 Modulærkabel RJ12 (6/6) 5 SIReCC610 85 022 97 Modulærkabel RJ12 (6/6) 10 SIReCC615 85 022 98 Modulærkabel RJ12 (6/6) 15 SIReCC403 85 022 99 Modulærkabel RJ11 (4/4) 3 SIReCC405 85 023 01 Modulærkabel RJ11 (4/4) 5 SIReCC410 85 023 02 Modulærkabel RJ11 (4/4) 10 SIReCC415 85 023 03 Modulærkabel RJ11 (4/4) 15 Maks. kabellengder Modulærkabel RJ12 (6p/6c) mellom SIReUB1 og SIReB1(X): maks. 50 m. Modulærkabel RJ12 (6p/6c) mellom to SIReB1(X): maks. 50 m. Modulærkabel RJ11 (4p/4c) til romføler SIReRTX: maks. 20 m. Total kabellengde som tillates i systemet, er maksimalt 300 m. 15

NO Vannregulering - ventilsett VOS SD230 TBVC BPV10 AV Vannregulering - ekstrautstyr VOSP SD230 TBVCMP BPV10 AV VAT, justeringsverktøy for ventilpakke. Type Beskrivelse Tilkobling VOS15LF På/av DN15 VOS15NF På/av DN15 VOS20 På/av DN20 VOS25 På/av DN25 VOSP15LF Trykkuavhengig DN15 VOSP15NF Trykkuavhengig DN15 VOSP20 Trykkuavhengig DN20 VOSP25 Trykkuavhengig DN25 VOT15 Treveisventil og regulator på/av DN15 VOT20 Treveisventil og regulator på/av DN20 VOT25 Treveisventil og regulator på/av DN25 VAT Justeringsverktøy for ventilpakke 16

Driftsmodus Driftsmoduser Fabrikkinnstillingene gir manuell vifteregulering og termostatstyrt varme ved valgt trinn. Stille inn verdier Bruk pil opp/ned til å velge ønsket romtemperatur, viftehastighetstrinn og varmetrinn. NO Automodus Endre parameter P04 fra 0 til 1 (se parameterliste på neste side) for å aktivere automodus. Still inn maksimal viftehastighet, så styrer termostaten varmen ved å åpne/lukke regulator/ventil og øke/ redusere viftehastigheten fortløpende. Når ønsket romtemperatur er oppnådd, lukkes regulatoren/ventilen, og viften stopper. Maksimal viftehastighet i Auto-modus er begrenset til trinn 4. Trykk på bekreftknappen. Tallet/tallene begynner å blinke. Verdien kan nå justeres med pil opp/ned og bekreftknappen. Manuell drift Senk temperaturinnstillingen under 5 C. Følgende symboler vises i statusvinduet = manuell modus. I manuell modus reguleres både vifte- og varmetrinn manuelt. Temperatur Viftehastighetstrinn Varmetrinn C 20-3 _ 1 Ettergang vifte Når varmen er aktivert, fortsetter viften å kjøre for å kjøle ned apparatet. Ettergangstiden er 180 sekunder eller kortere hvis interntemperaturen har falt under +30 C (gjelder bare for apparater med intern temperaturføler). System PÅ/AV Trykk på PÅ/AV-knappen i 2 sekunder for å slå av systemet. Enhetens sikkerhetsfunksjoner er fortsatt aktive etter at systemet er slått av, som betyr at viften kan fortsette å kjøre en stund etter at AV-modus er valgt. 17

NO Kontrollenhet SIReUB1 Oversikt C Statusvindu Gjeldende romtemperatur 208. Pil opp blar oppover Bekreft C Ønsket romtemperatur Pil ned blar nedover 20 Viftehastighetstrinn - 3 Alarm, rød lysdiode Kjøresignal, grønn lysdiode Varmetrinn PÅ/AV-knapp _ 1 Forklaringer Statusvindu Statusvinduet har fire hovedvisninger: gjeldende og ønsket romtemperatur, vifte- og varmetrinn. Alarmkoder og parameterinnstillinger kan også vises i statusvinduet. Bekreft Gir tilgang til installatørmenyen, til å velge parametere og bekrefte en justert innstilling. Etter ca. 20 sekunder går kontrollenheten tilbake til å vise gjeldende temperatur. Pil opp Bla opp i menyen / øke en innstilling. Pil ned Bla ned i menyen / redusere en innstilling. 18

Installatørmeny Parametermeny Hold bekreftknappen inne til P00 vises i statusvinduet. Bruk pil opp/pil ned til å bla mellom parameterne. Trykk en gang på bekreftknappen for å endre en innstilling på parametermenyen. Blinkende verdier kan justeres med pil opp/ned og bekreftknappen. Hold bekreftknappen inne for å komme tilbake til statusvinduet. (Statusvinduet vises automatisk på nytt etter ca. 50 sekunder.) Parameterbeskrivelse P.00 Temperaturforskjell varmetrinn Stiller inn forskjellen mellom viftetrinnene (i automatisk modus der termostaten også styrer viftehastighetstrinnene) NO P.01 Overopphetingsalarm PÅ/AV Mulighet til å blokkere alarmen (gyldig bare for apparater med intern temperaturføler). P.02 Ettergangstid Tid der viften fortsetter å kjøre når varmen er aktivert (gyldig bare for apparater med intern temperaturføler). P00. P01. P02. P02.. P13. P.03 Temperaturgrense for ettergang Ettergangstid avbrytes hvis den interne temperaturen faller under denne innstilte verdien (gyldig bare for apparater med intern temperaturføler). P.04 Vifteregulering Velg manuell (0) eller auto (1), les mer under avsnittet Driftsmodus. P.05 Interntemperatur Gjeldende interntemperatur. Bare toppverdien vises når flere apparater er tilkoblet (gjelder bare for apparater med intern temperaturføler). P.06 - P.13 Kjøretid Kjøretid for vifte- og varmetrinn. Parameterliste Parameternummer Beskrivelse Innstillingsområde Fabrikkinnstilling P.00 Temperaturforskjell mellom varmetrinn 0,5-10 1.0 C P.01 Overopphetingsalarm PÅ/AV PÅ=1; AV=0 1/0 1 P.02 Ettergangstid når varme er aktivert 10-300 180 s P.03 Temperaturgrense for ettergang vifte 10-40 30 C P.04 Vifteregulering: Manuell eller Auto; 0=Manuell, 1 = Auto 0/1 0 P.05 Visning av apparatets interntemp./utblåsn.temp. 0-100 P.06 Kjøretid viftetrinn 1 0-99999 P.07 Kjøretid viftetrinn 2 0-99999 P.08 Kjøretid viftetrinn 3 0-99999 P.09 Kjøretid viftetrinn 4 0-99999 P.10 Kjøretid viftetrinn 5 0-99999 P.11 Kjøretid varmetrinn 1 0-99999 P.12 Kjøretid varmetrinn 2 0-99999 P.13 Kjøretid varmetrinn 1+2 0-99999 19

NO Alarm- og feilkoder Overopphetingsvern Gjelder bare for apparater med intern føler. Overopphetingsbeskyttelsen skal begrense avtrekkstemperaturen til +90 C. Ved +90 C lukkes regulatoren for tilførsel av varme. Regulatoren åpner igjen hvis interntemperaturen faller under +85 C. Hvis temperaturen likevel fortsetter å stige, for eksempel på grunn av feil på en ventil/ regulator, begynner viften å rotere ved +95 C for å holde temperaturen nede. Samtidig startes en overopphetingsalarm Aot. Ved interntemperaturer på +100 C kjører viften på maksimal hastighet. Hvis apparatet kjøles ned, aktiveres varmen igjen. Alarmen blir stående i displayet til kontrollenheten. Hvis apparatet overopphetes to ganger i løpet av en time, må alarmen tilbakestilles før oppvarming kan aktiveres igjen. Viften kjører til alarmen er tilbakestilt. NB! Utfør en grundig kontroll ved gjentatte alarmer og overopphetingsalarmer, og kontakt autorisert servicepersonale eller Frico hvis du ikke finner årsaken til feilen. Tilbakestilling alarm NB! Før tilbakestilling må du sjekke at feilen er rettet opp, og at det ikke er noe som hindrer apparatet fra å settes i drift igjen! Når feilen er rettet opp, skal alarmen tilbakestilles i henhold til beskrivelsen nedenfor. Alarmvisningen blir borte hvis du trykker på "feil" knapp, men vises i statusvinduet igjen etter ca. 20 sekunder. Ved første oppstart kan det oppstå alarmer og feilkoder, disse kan vanligvis tilbakestilles uten ytterligere tiltak. 3 sekunder Visning av alarm og feilkoder Ved en alarm eller en feil vises alarmen/ feilkoden og apparatet den gjelder for, i statusvinduet. For alarmfeilkoder se Tabell - neste side. Statusvinduet veksler mellom å vise alarm/feilkode og ID-en til apparatet som forårsaker problemet. Aot. U02. Alarmkoden begynner å blinke Ert. res. 20

NO Tabell - Alarm Alarm Årsak Handling A.FA Motor alarm Termobryter er utløst. En eller flere motorer er overopphetet. (Bare apparater med uttrukkede termobrytere.) A.ot Overopphetingsalarm Temperaturen i apparatet har oversteget alarmgrensen for overoppheting. (Gjelder bare for apparater med interntemperatur.) Kontroller at ikke noe sperrer for apparatets luftinntak og -uttak. Når den overopphetede motoren har kjølt seg ned, lukkes termobryteren igjen, og alarmen kan tilbakestilles. Sjekk motorene ved gjentatte alarmer, og bytt ut ødelagte motorer. Kontroller at ikke noe sperrer for apparatets luftinntak og -uttak, funksjonen til regulatoren/ventilen, returvann og interne temperaturfølere i apparatet. Tabell Error - code Feilkoder Cause Action Feilkode Årsak Handling E.co Kommunikasjon Kommunikasjon SIReB1(X) har ikke kontakt med SIReUB1. PC-kort SIReB1(X) har ingen ID = 0 To eller flere SIReB1(X) har samme IDnummer En eller flere SIReB1(X) mangler programmer. E.cF ID-feil To eller flere SIReB1(X) i systemet har forskjellige programmer. E.rt Romfølerfeil Feil i eller manglende ekstern romføler SIReRTX (ekstrautstyr) koblet til SIReB1(X). E.It Intern følerfeil Feil på eller manglende føler i apparatet (gjelder bare apparater med intern føler). E.ru Romfølerfeil Feil på intern romføler i kontrollenhet SIReUB1. Kontroller tilkoblingen mellom SIReB1 og SIReUB1. Bytt ut eventuelle modulærkabler. Avbryt strømforsyningen og velg forskjellige ID-numre for alle SIReB1(X) i systemet. Avbryt strømforsyningen og velg forskjellige ID-numre for alle SIReB1(X) i systemet. Kontakt Frico for støtte. Kontakt Frico for støtte. Koble alltid fra strømforsyningen ved tilkobling eller frakobling av følere. Kontroller følerens tilkobling. Kontroller følerens tilkobling. Hvis føler mangler, kontakt Frico for støtte. Kontroller tilkoblingene mellom SIReUB1 og SIReB1(X). Bytt ut eventuelle modulærkabler. Kontroller om en ekstern føler SIReRTX (ekstrautstyr) fungerer. Hvis feilen ikke er rettet opp, må SIReUB1 byttes ut. 21

PE N L X4 C1 X5 C2 SIRe Basic Fan Heaters Water Wiring diagram Basic C SUPPLY 230V ACTUATOR 230V X3 ROOM SIReB1 SIReSD230 SIReRTX (optional) SIReUB1 44

SIRe Basic Fan Heaters Water Wiring diagram Basic parallell SIReB1 SIReSD230 X5 C2 X4 C1 X3 ROOM PE N L SUPPLY 230V ACTUATOR 230V SIReB1 SIReSD230 X5 C2 X4 C1 X3 ROOM PE N L SUPPLY 230V ACTUATOR 230V SIReB1 SIReSD230 SIReRTX (optional) SIReUB1 X5 C2 X4 C1 X3 ROOM PE N L SUPPLY 230V ACTUATOR 230V 45