VEKSELVENTILKASSER ND50-ND150, NT10 X-over Valve Manifolds ND50-ND150, PN10



Like dokumenter
PTM Valve Manifolds with Eltorque Actuators

Product Facts. Product code example

Complete tank expertise

SHORE POWER CONVERTER LIST 2018

Robertson S35 NFU Steering Lever

AVS MAGMA SOLENOID VALVES

Data Sheet for Joysticks

The regulation requires that everyone at NTNU shall have fire drills and fire prevention courses.

Open Burner - 12" 2009 Viking Commercial Division 40

HOBBYFISKERENS DRØM THE FISHERMANS DREAM

REMOVE CONTENTS FROM BOX. VERIFY ALL PARTS ARE PRESENT READ INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION

MICROHALER HMH-03/05 MICRO HAULER HMH-03/05

Sveiste stålrør Welded steel pipes EN 10217

Windlass Control Panel

SERVICE BULLETINE

Institutt for biovitenskap

Data Sheet for Joysticks

THE SOLUTION YOU VE BEEN LOOKING FOR MANUELLE VENTILER

Version Type For valve series Page/ MFH MOFH JMFH JMFDH NVF3 MUFH MN1H JMN1H JMN1DH VZWM-L Internet F solenoid coil MSF

VENTILER. Magnetventiler Shuntventiler ESBE (sleide) Motoriserte kuleventiler Ventilmotorer for ESBE-ventiler...

Data Sheet for Joysticks

EFFICIENCY, SAFETY, ECONOMY AND HEALTH

Data Sheet for Joysticks

DC/AC inverters DC/AC invertere

Monteringsprosedyre for Soundstop - lydmatte

HOBBYFISKERENS DRØM KB03 THE FISHERMANS DREAM KB03

- Vennlig hilsen gründerne bak retyre

NEOREST Hybrid (Toilet bowl) NEOREST Hybrid. Installation manual. Safety Cautions Precaution before installation. Included parts.

AIR. Verdens minste enkelrørskinne! AIR. Verdens minste 2016 enkelrørsskinne!

Aktuator Elektrisk, Ajac

MCP-16RC, luftrenertårn

Bytte til split Collin Lanyard RSL. Obligatorisk - alle rigger skal ha dette montert ved hopping etter

ALUMINUM TWIN STACK PORTABLE AIR COMPRESSOR OL50135AL OPERATOR S MANUAL

Aktuator Elektrisk, ELQ

Cylindrical roller bearings

INSTALLATION GUIDE FTR Cargo Rack Regular Ford Transit 130" Wheelbase ( Aluminum )

Materialvalg sett fra en leverandør

SafeRing / SafePlus Retrofit of under voltage coil V Module

MONTASJEANVISNING INSTRUCTIONS FOR ASSEMBLY AND USE

HONSEL process monitoring

KONGSBERG MARITIME AS Simulation & Training Tone-Merete Hansen Area Sales Manger

INSTALLATION GUIDE FTR Cargo Rack Regular Ford Transit 130" Wheelbase ( Aluminum )

Instruksjons manual Instruction manual

Mulig posisjon Possible position. Anbefalt posisjon Recommended Recommended Possible Possible Not recommended. Mulig posisjon Possible position

MONTASJEBESKRIVELSE INSTALLATION GUIDE

Elektronisk termostat med spareprogram. Lysende LCD display øverst på ovnen for enkel betjening.

CYL KNIFE VALVES,S.L. 702-PRE SERIESKYVESPJELDVENTILER

Mounting the electrically elevating legrest

Parker Hannifin AS. Making parts and systems all over the world

Replacing the carbon brushes

Actuators & Positioners Characterizable Pneumatic Positioners Series AV1/2/3/4

STILLAS - STANDARD FORSLAG FRA SEF TIL NY STILLAS - STANDARD

Dreiespjeldventil EVBS, EVBLS, EVS

Dagens tema: Eksempel Klisjéer (mønstre) Tommelfingerregler

Original instructions. Infrared heater IRCF

1. SAFE CARGO HANDLING

Eksamen KVT2002 Elenergi og automatiseringssystem/systemer. Programområde: Kulde- og varmepumpeteknikk. Nynorsk/Bokmål

TRAPPETA RN MONTERINGSANVISNING

Gudrun & Valemon Prosjektene Elektriske Aktuatorer

PE trykkrør. Katalogdel

NY! Pneumatisk slangeventil type VMC Air operated Pinch Valve type VMC. The flexible modular system for solvable and aseptic piping connections!


Vi skaper tilgjengelighet

Replacing the tube and/or tyre of a drive wheel, indoor/outdoor

Exercise 1: Phase Splitter DC Operation

VALVES & PIPING MATERIAL PRODUCT CATALOGUE VOL 1

1. Description Design Dimensions, weights Placement and Assembly Pressure loss... 19

RF Power Capacitors Class kV Discs with Moisture Protection

Side 1. Delekatalog Scanreco RC

User manual English Svenska Norsk

Elztrip EZ 300. Elztrip EZ300. Trepanels varmestråler for lagre, verksteder og lignende

C C A Stainless Steel A F593/F594 Stuffing Box A. Stuffing Box O-Ring/gasket C/F594. Grade Grade

BRUKER MANUAL SWING GATE OPENER

bondura Multi Tool 200 Hydraulic Ø200mm - Ø320mm user manual - for disassembly

DANGER. Carbon Monoxide. Using a generator indoors WILL KILL YOU IN MINUTES. Carbon Monoxide

ZB5AD4 ( ) Venderhode 2 pos.ret. h sort

Trådløsnett med Windows XP. Wireless network with Windows XP

Water terminals SYSDUCT HP. Ductable fan coil unit

Capstan type HC03 Capstan type HC03

Recommended machine weight:

KAMPANJE APK : APK-5: Skifte pakninger mellom turbo og CCDPF

Uponor Pro 1" Manifold Installation instructions UK. Fördelare Installationsanvisningar SE. Fordeler Monteringsanvisning NO

AC/DC Power supplies, switch mode AC/DC Kraftaggregater, switch mode

SafeRing / SafePlus Retrofit of auxiliary switch S10 for position indication of earthing switch De module

Replacing the batteries

Statens vegvesen. Testene tilfredsstiller kravene til styrkeklasse T3 med en målt arbeidsbredden på 0,7m.

1. Description Design Communication and control devices Dimensions, weights... 9

NOTBLOKKER KB, FM POWER BLOCKS KB, FM

Berøringsfritt eksosavtrekkssystem

Årsaksmodellering i offshore risikoanalyser - Scenarioer og aktiviteter

Software applications developed for the maritime service at the Danish Meteorological Institute

RF Power Capacitors Class1. 5kV Discs

Cylindrical roller bearings

TUNNEL LIGHTING. LED Lighting Technology

ZAK -Systemet. Korrosjonsfritt // Gjengefritt // Lett å montere

Unit Relational Algebra 1 1. Relational Algebra 1. Unit 3.3

710A, Configurable. A powerful dust collector, excellent high vacuum for suction over long horizontal and vertical distance

ELSEMA 1, 2, 4-Channel 27MHz Transmitter FMT312E, FMT31202E, FMT31204E

Transkript:

VEKSELVENTILKASSER ND50-ND150, NT10 X-over Valve Manifolds ND50-ND150, PN10 Box Ø50 Box Ø80 Box Ø100 Box Ø125 Box Ø150 B=Ca. 258 B=Ca. 276 B=Ca. 317 B=Ca. 406 B=Ca. 453 C=80 C=100 C=120 C=150 C=180 D=120 D=150 D=170 D=220 D=250 E=300 E=360 E=402 E=524 E=584 F=17 F=17 F=17 F=22 F=22 G=M12 G=M16 G=M16 G=M20 G=M20 ØH=94 ØH=130 ØH=154 ØH=184 ØH=221 1=90 1=120 1=140 1=170 1=200 K=M12 K=M16 K=M16 K=M20 K=M20 ØM=65 ØM=80 ØM=100 ØM=130 ØM=156 ØN=80 ØN=100 ØN=120 ØN=150 ØN=180 O 152 O 182 O 202 O 264 O 294 P 105 P 125 P 140 P 184 P 215 X 80 X 95 X 108 X 117 X 135 Y 120 Y 130 Y 150 Y 180 Y 225 Z 110 Z 125 Z 138 Z 172 Z 195 S 15 S 15 S 18 S 22 S 25 No. of boxes 1 2 3 4 No. of cell=t 2 3 4 5 6 7 8 9 10 11 12 Type (Construction) 0002 0003 0022 0023 0033 0223 0233 0333 2 233 2 333 3 333 Length A Ø50 box 310 430 621 741 861 1 052 1 172 1 292 1 483 1 603 1 723 Length A Ø80 box 350 480 701 831 961 1 182 1 312 1 442 1 663 1 793 1 923 Length A Ø100 box 396 546 792 942 1 092 1 338 1 488 1 638 1 884 2 034 2 184 Length A Ø125 box 469 649 938 1 118 1 298 1 587 1 767 1 947 2 236 2 416 2 596 Length A Ø150 box 555 780 1 110 1 335 1 560 1 890 2 115 2 340 2 670 2 895 3 120 All dimensions in mm. Subject to alteration without further notice. Alle dimensjoner i mm. Vi forbeholder oss retten til å gjøre endringer uten å melde fra.

LENSEVENTILKASSER ND50-ND150, NT10 Bilge-water Valve Manifolds ND50-ND150, PN10 Box Ø50 Box Ø80 Box Ø100 Box Ø125 Box Ø150 B=Ca. 220 B=Ca. 230 B=Ca. 263 B=Ca. 313 B=Ca. 373 C=80 C=100 C=120 C=150 C=180 D=120 D=150 D=170 D=220 D=250 E=150 E=180 E=200 E=260 E=290 F=17 F=17 F=17 F=M22 F=M22 G=M12 G=M16 G=M16 G=M20 G=M20 ØH=94 ØH=130 ØH=154 ØH=184 ØH=221 1=90 1=120 1=140 1=170 1=200 K=M12 K=M16 K=M16 K=M20 K=M20 ØM=61 ØM=86 ØM=106 ØM=132 ØM=155 ØN=80 ØN=100 ØN=120 ØN=150 ØN=180 P 50 P 60 P 70 P 90 P 110 X 70 X 85 X 98 X 117 X 132 Y 120 Y 130 Y 150 Y 180 Y 225 Z 70 Z 85 Z 98 Z 117 Z 133 S 15 S 15 S 18 S 22 S 22 No. of boxes 1 2 3 4 No. of cell=t 2 3 4 5 6 7 8 9 10 11 12 Type (Construction) 0002 0003 0022 0023 0033 0223 0233 0333 2 233 2 333 3 333 Length A Ø50 box 260 380 521 641 761 902 1 022 1 142 1 283 1 404 1 523 Length A Ø80 box 300 430 601 731 861 1 032 1 162 1 292 1 463 1 593 1 723 Length A Ø100 box 346 496 693 843 993 1 190 1 340 1 490 1 687 1 837 1 987 Length A Ø125 box 414 594 828 1 008 1 188 1 422 1 602 1 782 2 016 2 196 2 736 Length A Ø150 box 490 715 980 1 205 1 430 1 695 1 920 2 145 2 410 2 635 2 860 All dimensions in mm. Subject to alteration without further notice. Alle dimensjoner i mm. Vi forbeholder oss retten til å gjøre endringer uten å melde fra.

VENTILKASSE MED FJERNSTYRING Valve Manifolds with Remote Control VENTILKASSE / Bilge-water Valve Box Ø80 Box Ø100 Box Ø125 Box Ø150 AA 66 80 100 120 AB 173 221,5 260 290 AC 184 210 226 230 AD 423 511,5 586 640 All dimensions in mm VEKSELVENTILKASSE / X-over Valve Box Ø80 Box Ø100 Box Ø125 Box Ø150 AA 191 220 284 335 AB 173 221,5 260 290 AC 184 210 226 230 AD 548 651,5 770 855 Alle dimensjoner i mm FJERNSTYRINGSPANEL / Remote Control Panel

TABELL FOR VENTILKASSE Size table for valve manifolds Type Draw.no End flange Bottom flange Blind flange Hole Ø (mm) ND s ize Draw.no Hole Ø (m m) ND s ize Draw.no Hole Ø (mm ) ND s ize P40564 79 65 P40566 63 50 P40565 ND 50 P30657 117 100 P40567 91 80 P30658 ND 80 P30657.1 91 80 P40567.1 78 65 P30657.2 78 65 P40567.2 63 50 P30659 144 125 P40568 117 100 P30660 ND 100 P30659.1 117 100 P40568.1 91 80 P21809 170/150 150 P21810 141/125 125 P21811 ND 125 P212590 144 125 P21804 195/180 175 P21805 170/150 150 P21806 ND 150 Steel pipe N.D. O.D. (mm) 40 48,3 50 60,3 65 76,1 80 88,9 100 114,3 125 139,7 150 168,3 175 193,7 200 219,1 250 273,0 Ulstein Ventilkasser Design Det er lagt vekt på et kompakt design for å spare plass ombord. Ventilhusene er støpt i ett stykke. Ventilsetene er montert i separat, og kan tas ut ved behov. Ventilene kan enten være løse eller fast montert til spindelen. For lensekasser benyttes kun ventiler som ikke er fast montert til spindelen ( non-return ). Test og bruk Maksimum arbeidstrykk er 10 bar. Alle ventilkassene teste/ trykksettes før de leveres. Ventilkassene kan kun benyttes i Klasse III rørsystemer. Ulstein Ventilkasser er typegodkjent av Det Norske Veritas, sertifikat nr. P- 10635. Leveringsomfang Ventilkassene leveres uten bolter og muttere Motflenser og pakninger er opsjoner, men leveres når spesifisert Blind-/Endeflenser leveres med O-ringer Bunnflenser leveres med pakninger Ulstein Valve Manifolds Design A compact design is emphasised due to space-saving onboard. The houses are casted in one piece with removable seats. The valves can be of non return type or valves locked to the spindle. When the chests are used in bilge systems, the non-return valves to be used. Testing and usage Maximum working pressure is 10 bar. All valve manifolds are tested/ pressurised before they leave the factory. The chests can only be used for Class III piping systems. The Ulstein Valve Manifolds are type approved by Det Norske Veritas, certificate no. P-10635. Scope of supply All valve manifolds are delivered without bolts and nuts Counter flanges and gaskets are optional, but delivered upon specification Blind-/Endflanges are delivered with O-rings Bottom flanges are delivered with gaskets Fjernstyring av ventilkasser Ventilkasser som kan fjernstyres har fått erstattet rattene med pneumatiske aktuatorer. Disse er montert på hver sin brakett og opereres via magnetventiler som igjen styres fra lokale betjeningspaneler eller eksterne styresystemer. Endebrytere er påmontert hver aktuator for indikering av åpen og stengt posisjon. Ventilskap Magnetventilene er innmontert i et separat skap, beregnet for skottmontering i nærheten av ventilkassen. Ventilene kan være enten bistabile (2 spoler) eller unistabile (1 spole). Bistabile magnetventiler blir stående i posisjon ved spenningsbortfall, mens unistabile ventiler går tilbake til utgangsposisjon. Magnetventiler kan leveres for både 24VDC og 230 VAC Lokal betjening Vendere for operering av magnetventilene samt lysdioder for indikering åpen/stengt er montert i fronten av et lokal betjeningsskap. Rekkeklemmer for tilkopling av eksterne styresystemer er inkludert. Lokal-betjeningsskapet er lagret for skottmontering. Fjernbetjeningspanel med mimikk Ventilkassene kan fjernbetjenes fra egne kontrollpanel i kontrollrom eller på bro. Panelene er laget for montering i pult. Beskyttelsesgrad er IP54. Vendere for operering av magnetventilene samt lysdioder for indikering åpen/stengt er montert. I tillegg kan mimikk-diagram graveres inn i toppfolien på panelene. Start/stopp av pumper samt operasjon av eksterne ventiler kan inkluderes i kontrollpanelenes funksjoner. Remote controlled valve manifolds have got pneumatic actuators instead of hand wheels. Each actuator is mounted on a bracket and is operated by means of solenoid valves. Micro-switches are mounted on each actuator for indication of open/ closed position. Solenoid valve cabinet The solenoid valves are assembled in a cabinet for bulkhead mounting nearby the valve manifold. Bistable (2 coils) or unistable (1 coil) solenoid valves may be used. Bistable solenoid valves remain in position if a blackout condition occurs, whereas unistable solenoid valves return to the original position. Solenoid valves are available for both 24 VDC and 230 VAC. Local operation Switches for operation of solenoid valves and LEDs for indication of open/closed position are assembled in front of a local operation cabinet, made for bulkhead mounting. Terminals for connection to external control systems are included. Remote control panel with mimic diagram The valve manifolds may be remote controlled from separate control panels in the engine control room or from the bridge. The control panels are made for desk mounting. Protection degree is IP54. Switches for operation of solenoid valves and LEDs for indication of open/closed position are included. In addition, the mimic diagram can be engraved on the top of the panel. Start/stop of pumps, together with the operation of external solenoid valves can be included on the control panel.

ULSTEIN VENTILKASSER Mange modeller for ulike formål. Vekselventilkasser og lenseventilkasser Kompakt design Manuell eller fjernstyrt betjening Fjernstyring kan leveres ved oppgradering eller ombygging Tilhørende spesialflenser og tetninger inkluderes Vi forbeholder oss retten til å gjøre endringer uten å melde fra ULSTEIN Valve Manifolds Several models for various duties including X-over and bilge-water purposes Compact design Manual or remote operation Remote control can be supplied for upgrading and retrofit Counter flanges and gaskets included in scope. Subject to alteration without further notice