Water terminals SYSDUCT HP Ductable fan coil unit
SYSDUCT HP Ductable fan coil unit The ductable air treatment units are available in 7 sizes. Units are extremely suitable for small centralized conditioning systems connected by a small ducting network. The small height of these units, make them the convenient solution for false ceiling installation. Structure Made of heavy gauge galvanised steel (1,5 mm) it is insulated in all parts in direct contact with the conditioned air. Insulated condensate tray made of galvanised steel, complete with drain plug for complete drainage. Air filter Filtering Polyester fabric enclosed within a metal frame to facilitate withdrawal and cleaning. Filtering rate of the standard model: EU3. Available with different filtering rate on request. Coil Coils are made of copper pipe expanded into aluminium fins. Copper headers with male fittings (GAS threads) and easily accessible air vents. In the standard version, the water connections are located on the left (looking at the air outlet). On request, the water connections can be placed on the right side of the unit. Ceiling-anchoring slots for easy fixing and levelling of the unit. Fan group Double-inlet centrifugal fans with statically and dynamically balanced horizontally-oriented aluminium impellers. Single-phase asynchronous electric motor with overload cutout. The motor with three speeds is directly coupled to the fans and cushioned with flexible mountings to ensure low noise. SYSDUCT HP Accessories Wide range of controllers Infrared remote Electronic thermostat with Electronic thermostat controller switch selectors for flush mounting Available accessories 2way or 3way valves with on/off or modulating actuators 9 air intake and supply plenum Section with fresh air louver Air filter, EU3 class Connecting flange Antivibrating joint Heating section with electric heater Straight air intake and supply plenum Intake and supply section with spigots 4 and 6 rows heat exchanger for cooling up to 61kW 9 air intake and supply plenum Antivibrating joint Straight air intake and supply plenum Intake and supply section with spigots Section with fresh air louver Heating section with electric heater ModBus or BacNet PC connection Aeraulic performances (2 pipe system) SYSDUCT HP 1 SYSDUCT HP 2 SYSDUCT HP 3 SYSDUCT HP 4 SYSDUCT HP 5 SYSDUCT HP 6 4R coil data SYSDUCT HP 7 4R coil data 16 14 12 1 8 3 4 MAX 6 4 2 68 db(a ) 1 2 3 4 5 6 7 8 9 16 14 12 1 8 3 4 MAX 6 4 2 1 2 3 4 22 2 18 16 14 12 1 8 6 4 2 2 4 22 2 18 16 14 12 1 8 6 4 2 2 4 33 3 27 24 21 18 15 12 9 6 3 3 6 4 36 32 28 24 2 16 12 8 4 5 1 4 36 32 28 24 2 16 12 8 4 1 2 5 6 7 8 9 1 11 12 13 14 15 6 8 1 12 14 16 18 2 6 8 1 12 14 16 18 2 9 12 15 18 21 24 27 3 15 2 25 3 35 4 45 5 3 4 5 6 7 8 9 1 22 33 55 11 )
Technical data Technical data Model SYSDUCT HP (2 PIPE SYSTEM - STANDARD COIL) 21 22 23 24 25 26 27 COOLING Inlet water temp.: 7 C water temp.: 12 C Inlet air temp.: 27 C d.b.-19 C w.b. HEATING Air temp.: 2 C Inlet water temp.: 5 C FURTHER DATA Model SYSDUCT HP (4 PIPE SYSTEM - STANDARD + AUXILIARY COIL) 41 42 43 44 45 46 47 COOLING Inlet water temp.: 7 C water temp.: 12 C Inlet air temp.: 27 C d.b.-19 C w.b. HEATING Air temp.: 2 C Inlet water temp.: 7/6 C FURTHER DATA Total cooling Sensible cooling Total cooling Sensible cooling W max 287 611 81 844 123 2154 395 W med 286 57 634 81 997 22 373 W min 275 45 55 66 847 183 333 W max 24 434 67 695 965 17 32 W med 236 394 6 67 754 159 31 W min 23 345 57 54 634 143 267 Water flow l/h max 492 95 1384 145 2116 3697 5359 Water pressure drop kpa max 15,4 26,9 31,5 24 25,8 21,1 25,1 W max 34 62 825 945 115 337 61 Heating W med 337 59 8 91 95 319 581 W min 323 47 673 78 815 294 528 Water flow l/h max 298 495 725 829 11 3696 536 Water pressure drop kpa max 2,3 13 3 18 23 17,6 19,6 m 3 /h max 57 165 175 168 264 3623 7143 Air flow m 3 /h med 567 114 1461 156 186 338 657 m 3 /h min 54 85 118 1181 147 295 5613 Pa max 6 6 59 6 6 122 121 ESP Pa med 5 5 5 5 5 1 1 Pa min 35 35 31 35 35 67 77 W max 39 56 89 94 131 2464 448 W med 296 53 78 898 115 233 4288 W min 283 45 739 74 88 281 384 W max 24 434 657 751 96 1837 344 W med 23 41 622 713 84 1735 3281 W min 218 33 526 575 647 1534 2915 Water flow l/h max 53 956 14 178 256 4227 7675 Water pressure drop kpa max 15,3 26,9 31,4 27,8 26 27,7 29,3 W max 397 67 1 112 165 2882 532 Heating W med 379 631 94 18 144 2716 589 W min 36 53 835 88 1 24 452 Water flow l/h max 53 956 14 178 256 4227 7675 Water pressure drop kpa max 13 22,6 26,1 23,3 22 22,6 23,8 Electric heater W - 3. 6. 6. 9. 9. 12. 18. A - 4.5 9. 9. 12. 12. 18. 24. m 3 /h max 65 164 1764 178 265 3946 7731 Air flow m 3 /h med 61 94 1627 1728 2163 3645 7248 m 3 /h min 57 746 1293 1262 1442 312 6193 Pa max 6 6 59 6 6 122 121 ESP Pa med 5 5 5 5 5 1 1 Pa min 35 35 31 35 35 67 77 db(a) max 6 57 63 62 6 7 72 db(a) med 57 54 61 61 57 66 67 db(a) min 54 51 57 57 54 61 62 db(a) max 64 61 67 66 65 74 75 db(a) med 61 58 65 64 61 69 7 db(a) min 58 55 6 6 59 64 65 db(a) max 51 48 54 53 51 62 63 db(a) med 48 45 52 52 48 57 59 db(a) min 45 42 48 48 45 53 53 db(a) max 55 52 58 57 56 65 66 db(a) med 52 49 56 55 52 61 62 db(a) min 49 46 51 51 5 56 57 Power input W W 16 24 32 34 58 132 26 Absorbet current A A,72,97 1,43 1,51 2,58 5,86 11,54 Water content L L 1,36 2,18 2,63 3,25 3,79 9,38 14,44 db(a) max 6 57 63 6 69 7 72 db(a) med 56 56 6 56 65 66 67 db(a) min 54 52 57 54 58 61 62 db(a) max 64 61 68 64 69 74 75 db(a) med 6 6 64 6 66 69 7 db(a) min 58 55 62 58 58 64 65 db(a) max 51 48 54 51 6 62 63 db(a) med 47 47 51 47 56 57 59 db(a) min 45 43 48 45 49 53 53 db(a) max 55 52 59 55 6 65 66 db(a) med 51 51 55 51 57 61 62 db(a) min 49 46 53 49 49 56 57 Power input W max 16 24 32 34 58 132 26 Absorbet current A max,72,97 1,43 1,51 2,58 5,86 11,54 Water content (cooling) L - 1,36 2,18 2,63 3,25 3,79 9,38 14,44 Water content (heating) L -,45,73,88 1,8 1,26 4,69 7,22 Minimum air pressure loss necessary to ensure the correct functioning of the units. Minimum air pressure loss Pa 6 6 MODEL 1 2 3 4 5 6 7 Fans - Motors n 1-1 2-1 2-1 2-1 2-1 1-1 2-2 Standard coil Auxiliary coil Rows n 3 3 3 3 3 4 4 Fittings (ØAF) Ø 1/2 1/2 3/4 3/4 1 1 1/4 1 1/2 Rows n 1 1 1 1 1 2 2 Fittings (ØAF) Ø 1/2 1/2 1/2 3/4 3/4 1 1 1/4 Condensate drain fitting (ØC) Ø mm 2 2 2 2 2 2 2 External dimensions Height H mm 3 3 325 325 375 675 675 Lenght L mm 65 1. 1.1 1.34 1.34 1.341 2.28 Depth* P mm 533 533 533 533 533 853 853 Intake A mm 197 197 222 222 272 572 572 Supply M mm 197 197 222 222 272 39 * 39 * B mm 548 898 998 1.238 1.238 1.238 1.926 C mm 4 4 4 4 4 725 725 D mm 67 67 67 67 67 118 118 E mm 34 34 34 34 34 65 65 N. x Ø BAM mm 2xØ2 3xØ2 3xØ2 4xØ2 4xØ2 2xØ4 4xØ4 Net weight kg 28 36 41 46 57 117 192 * On request: supply dimension as intake dimension. Dimensions 7 34 37 44 37 51 51 B 51 L SYSDUCT HP 1-5 44 SYSDUCT HP 6-7 B 51 L 7 77 A 26 77 A 26 29 29 17 137 Ø 2 Ø 2 P 29 P 29 77 M 26 H 259 M 26 H
REFTEC AS Våre folk Trondheim REFTEC AS Vi kan kulde/varmepumpe og klimaprodukter Andrè Benjamin Erik Henrik Reftec AS ble etablert i 27 og er en bedrift med hovedkontor i Trondheim og avdelingskontor i Oslo. Våre ansatte består av unge teknisk orienterte medarbeidere innenfor fagområdet kuldeteknikk og varmepumpesystemer. Våre kunder i det norske markedet strekker seg fra ventilasjon og kuldebransje til rørleggere og totalentreprenører. Jan Ivar Johnny Jon Bjarte Ketil De ansatte i bedriften innehar lang fartstid i faget, noe som har gitt oss et høyt kompetansenivå. Reftec AS skal med høy servicegrad og punktlighet gi miljøbevisste kunder optimale energiløsninger. I vårt produktspekter inngår energioptimale produkter som blant annet varmepumper, isvannsmaskiner, dataromskjølere, fancoils, industrielle terminal uniter og kondenseringsaggregater. Vi har produkter til konkurransedyktige priser fra store europeiske leverandører som Systemair, Chiller OY og Argo. Lars Petter Per Wenche Morten Visjon: Oslo Energioptimale løsninger i et fremtidsrettet miljøperspektiv. Thomas Ole-Johnny Linn Christine
Reftec AS Tlf: 73 1 39 5 post@reftec.no www.reftec.no Trondheim: Vestre Rosten 85 Sigmasenteret 775 Tiller Oslo: Nordåsveien 5 1251 Oslo - Vi tenker miljø.