Original instructions RDS

Like dokumenter
Original instructions RDS

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 1 Uten varme 3 Elvarme: 8 30 kw 2 Vannbåren varme WL.

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 3 Elvarme: 8 30 kw 2 Vannbåren varme WL. For svingdører

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 1 Uten varme 3 Elvarme: 8 30 kw 2 Vannbåren varme WL.

SFS SFS. Designluftport for svingdører, med intelligent regulering. 3 Elvarme: 8 23 kw 2 Vannbåren varme WL. For svingdører

AGS5000 AGS5000. Luftport for dør/port i industrilokaler og store lokaler, med intelligent styresystem. 1 Uten varme 2 Vannbåren varme WH, WL

Original instructions AR

Corinte Designluftport for eksklusive inngangspartier, med intelligent regulering

Elektra H GB... 9 NO

Elektra F GB NO FR

PA2500W PA2500E. Elegant luftport for inngangspartier, med intelligent regulering. 3 Elvarme: 5-16 kw 2 Vannbåren varme

AD Corinte W - ADCS

Original instructions SFS

AR200 AR200. Innfelt luftport for små innganger. 1 Uten varme 3 Elvarme: 3 18 kw 2 Vannbåren varme. Anbefalt installasjonshøyde 2,5 m*

Original instructions PA2500

IR3000, IR4500, IR6000

Original instructions AR

AGS5500 AGS5500. Luftport for dør/port i industrilokaler og store lokaler, med intelligent styresystem. 1 Uten varme 2 Vannbåren varme WH, WL

Original instructions CAT

Original instructions AGS5500

Elektra V GB NO DE PL

Corinte Designluftport for eksklusive inngangspartier, med intelligent regulering

Original instructions. Thermoplus

Original instructions AR

Original instructions PA2500

PA2500 PA2500E. Elegant luftport for inngangspartier, med intelligent regulering. 1 Uten varme 3 Elvarme: 5-16 kw 2 Vannbåren varme

Original instructions SFS

Original instructions. Panther 6-15 kw

Original instructions. Panther 6-15 kw

Thermozone AD Corinte W - ADCS

Original instructions. SIRe Basic Quick guide. SIReB

Original instructions AR

t* 3 Lydnivå* 2 [ C] [db(a)]

Original instructions AR

Thermozone AD Corinte W - ADCS

AGI AGI. Solid luftport for store industridører. 1 Uten varme 2 Vannbåren varme WL. Horisontal og vertikal montering

Thermozone AGV 4000 A/E/W

AD Corinte. Thermozone AD Corinte. Luftporter for dører med høyde på opptil 3 meter

Original instructions. Comfortinfra CIR DE NL FI RU... 20

PA4200 Elegant luftport for forretnings- og industrilokaler, med intelligent regulering

Original instructions PA1508 NO DE ES

Original instructions. Thermoplus

PA2200C PA2200C. Elegant luftport for inngangspartier, med fjernkontroll og integrert regulering. 1 Uten varme 3 Elvarme: 3 16 kw 2 Vannbåren varme

Original instructions PA2200C NO DE ES... 46

AR200 AR200. Innfelt luftport for små innganger. 1 Uten varme 3 Elvarme: 3 18 kw 2 Vannbåren varme. Anbefalt installasjonshøyde 2,5 m*

Original instructions Elztrip EZ W

Original instructions. Infrared heater IRCF

PA3500 Elegant luftport for forretningslokaler, med intelligent regulering

Thermozone AG4000 A/E/W Luftporter for entrèer eller porter med høyde opp til 4 meter

Portier. Portier. Elegante luftporter for inngangspartier. 1 Uten varme 3 Elvarme: 3-13,5 kw. Anbefalt installasjonshøyde 2,5 m*

Thermozone RD. Eksklusiv luftportløsning for karuselldører

PA4200 Elegant luftport for forretnings- og industrilokaler, med intelligent regulering

Elztrip EZ

Original instructions PA3200C NO DE ES

Original instructions PA

Original instructions. SIRe Basic Air Curtains Water With quick guide. SIReB. For wiring diagram, please see last pages

Original instructions AGI4500/6000

Original instructions AR3200C FR

AR3200C AR3200C. Innfelt luftport for næringslokaler, med fjernkontroll og innebygd kontrollpanel. 1 Uten varme 3 Elvarme: 5-16 kw 2 Vannbåren varme

SIRe Basic Fan Heaters Water With quick guide SIReB

SIRe Basic, SIRe Competent. VOSP, trykkuavhengig ventilpakke on/off Komplett sett med toveis trykkuavhengig regulerings- og

PA3500/4200 PA3500/4200. Elegant luftport for forretnings- og industrilokaler, med intelligent regulering

Corinte. Corinte. Designluftport for eksklusive inngangspartier, med intelligent regulering. Anbefalt installasjonshøyde 3 m*

Varmluftsvifter SWT. Varmluftsvifter SWT. Takmontert varmevifte med vannbåren varme

Corinte. Corinte. Designluftport for eksklusive inngangspartier, med intelligent regulering. Anbefalt installasjonshøyde 3 m*

Comfortinfra CIR11021C

Original instructions. Thermozone ADA Cool RU

AR3200C AR3200C. Innfelt luftport for næringslokaler, med fjernkontroll og innebygd kontrollpanel. 1 Uten varme 3 Elvarme: 5-16 kw 2 Vannbåren varme

Original instructions. Infrared heater IRCF...17

Thermozone AD 300 A/E/W

t* 4 [db(a)] [db(a)] Lydeffekt* [db(a)] [ C]

Original instructions. SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see last pages

Original instructions. SIRe Basic Fan Heaters Water With quick guide. SIReB. For wiring diagram, please see last pages.

Elektra C GB NO

Original instructions. SIRe Basic Fan Heaters Electric With quick guide. SIReBX. For wiring diagram, please see last pages.

Original instructions CIR DE NL FI RU... 20

Varmluftsvifte SWTM. Varmluftsvifte SWTM. Takmontert varmevifte i rustbeskyttet utførelse med vannbåren varme. Produktspesifikasjoner

Thermozone AD 200 A/E/W Luftporter til dører med høyde inntil 2,5 meter

AGI4500/6000 AGI4500/6000. Solid luftport for store industridører. Anbefalt installasjonshøyde * AGI4500: 4,5 m AGI6000: 6 m. Lufthastighetsprofil

PA3500 Elegant luftport for forretningslokaler, med intelligent regulering

Varmluftsvifte SW02 Stillegående varmevifte for tilkobling til vann i små bygninger.

Elztrip EZ

PA4200 Elegant luftport for forretnings- og industrilokaler, med intelligent regulering

Varmluftsvifte SWX EX

Styresystem SIRe. Intelligent Tilpasser seg automatisk inngangen. Proaktiv funksjon Gir raskere reaksjon

LPG/GASSVARMER / BYGGTØRKER

Vannregulering VOS. Se vår hjemmeside eller kontakt oss i Frico for mer informasjon om våre ventilpakker. TBVC SD230 AV.

Thermozone SF. Luftporter for vertikal montering i svingdører

Luftporter for energieffektivitet og bedre komfort. Ny intelligent luftportserie PA-serien

Varmluftsvifter SWS. Varmluftsvifter SWS. Basisvarmevifte for vanntilkobling

Varmluftsvifte Elektra

Varmluftsvifte SWX C / D / H

Varmluftsvifte Cat. Varmluftsvifte Cat. Kompakt varmevifte for små lokaler

Driftsinstruks. Vannkjølt aggregat MEC. Vi håper de får stor glede av et Novema kulde produkt!

Varmluftsvifte Tiger. Varmluftsvifte Tiger. Robust varmevifte for bærbar bruk i krevende miljøer. Produktspesifikasjoner

Original instructions. Thermocassette HP

B r u k e r m a n u a l

Avtrekkshette NO Bruksanvisning

Kjøkkenhette NO Bruksanvisning

Thermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18

Transkript:

Original instructions RDS SE... 14 GB... 19 NO... 21 DE... 25 FR... 30 ES... 35 IT... 40 NL... 45 PL... 50 RU... 55

Top view L W R L [mm] RDS23 1000 RDS29 1000 RDS38 1500 RDS56 2000 RDS65 2500 Side view Min. 800 520 270 125 115 220 70 2

Suspended from ceiling ca 75 ca 80 ca 65 13 L/2 8 x M8 RDS23 RDS29 RDS38 RDS56 505 260 15 520 13 825 825 825 RDS65 10 x M8 3

Mounted on revolving door 100 223 22 520 Connections position W 85 617 160 51 Connections position E 400V 3~ RDSB L 40x80 25 Ø9 20 40 4

C RDS Accessories SIRe SIReB SIReAC SIReAA SIReRTX SIReUR SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReCC610 SIReCC615 SIReCC640 SIReCC403 SIReCC405 SIReCC410 SIReCC415 70x33x23 mm 114x70x50 mm 3 m 5 m 10 m 15 m 40 m 3 m 5 m 10 m 15 m SIReB SIReAC/SIReAA SIReRTX SIReUR SIReWTA SIReCJ4/SIReCJ6 SIReCC Type Connection VMO VMOP VMO15LF VMO15NF VMO20 VMO25 VMOP15LF VMOP15NF VMOP20 VMOP25 VOS15LF VOS15NF VOS20 VOS25 VOSP15 LF VOSP15NF VOSP20 VOSP25 VOT15 VOT20 VOT25 VMT15 VMT20 VMT25 VAT DN20 DN25 DN20 DN25 DN20 DN25 DN20 DN25 DN20 DN25 DN20 DN25 VOS VOT VMT VOSP VAT Accessories Type FH1025 RDSB Flexible hose DN25, inside thread, length 1 m Beam 40x80 mm FH1025 RDSB 5

RDS + RDSB (beam) 1 2 x2 x4 3 4 5 x4 6 7 8 x2 6

7 RDS E RDS23/29E RDS56/65E RDS23/29/38E SIReB1 Actuator Transformer 230V 200V 170V 145V 120V 100V N Black Black Grey Blue Blue White White Supply C2 C1 ROOM Internal sensor Motor protection Transformer 230V 200V 170V 145V 120V 100V N Yellow Orange Red Brown Black Green Blue RDS38E RDS65E RDS56E 400V3~ N L1L2L3

8 RDS W RDS23/29W SIReB1 Actuator Transformer 230V 200V 170V 145V 120V 100V N Black Blue White White Supply C2 C1 ROOM Internal sensor Motor protection Transformer 230V 200V 170V 145V 120V 100V N Yellow Orange Red Brown Black Green Blue RDS38W RDS65W RDS56W

SIReB Basic RDS A RDS E SIReB1/B2/B1EC SIReRTX (optional) SIReUB1 Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L L PE N L ~ SIReCC6XX (max 50 m) L2m SIReCC6XX (max 10 m) SIReB1/B2/B1EC Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L L PE N L ~ SIReCC6XX (max 50 m) SIReB1/B2/B1EC Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L L PE N L ~ Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe. 9

SIReB Basic RDS W SIReB1/B2/B1EC SD230 SIReRTX (optional) SIReUB1 Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L L PE N L ~ SIReCC6XX (max 50 m) L2m L1,5m SIReCC6XX (max 10 m) SD230 SIReB1/B2/B1EC Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L L PE N L ~ SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L L PE N L ~ Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe. 10

Output charts water Type Fan position Airflow Supply water temperature: 80 Room temperature: +18 Outlet air temperature: +35 * 1 Output Return water temp. [] Water flow Pressure drop Water temperature: 80/60 Room temperature: +18 Output* 2 Outlet Water air temp. flow Pressure drop [m 3 /h] [kw] [l/s] [kpa] [kw] [] [l/s] [kpa] RDS23WL max 2300 13,3 42,7 0,09 1,9 17,9 40,9 0,22 10,8 min 1050 6,1 32,7 0,03 0,3 11,0 48,9 0,13 4,3 RDS29WL max 2900 16,7 47,7 0,13 3,9 20,4 38,7 0,25 13,9 min 1300 7,5 34,1 0,04 0,5 12,6 46,6 0,15 5,6 RDS38WL max 3800 21,9 41,9 0,14 2,1 29,8 41,1 0,36 12,4 min 1800 10,4 31,5 0,05 0,3 18,8 48,7 0,23 5,1 RDS56WL max 5600 32,3 41,5 0,20 5,9 43,4 40,8 0,53 35,5 min 2700 15,6 30,3 0,08 1,0 27,8 48,3 0,34 15,1 RDS65WL max 6500 37,5 37,4 0,21 8,1 54,1 42,5 0,66 68,9 min 3100 17,9 27,9 0,08 1,4 33,9 50,2 0,41 27,7 Type Fan position Airflow Supply water temperature: 70 Room temperature: +18 Outlet air temperature: +35 * 1 Output Return water temp. [] Water flow Pressure drop Water temperature: 70/50 Room temperature: +18 Output* 2 Outlet Water air temp. flow Pressure drop [m 3 /h] [kw] [l/s] [kpa] [kw] [] [l/s] [kpa] RDS23WL max 2300 13,3 46,8 0,14 4,7 14,1 36,1 0,17 6,9 min 1050 6,1 34,5 0,04 0,5 8,7 42,5 0,11 2,8 RDS29WL max 2900 16,7 52,3 0,23 12,5 16,1 34,3 0,20 8,9 min 1300 7,5 37,0 0,06 0,9 10,0 40,7 0,12 3,6 RDS38WL max 3800 21,9 46,1 0,22 5,0 23,6 36,3 0,29 8,0 min 1800 10,4 34,1 0,07 0,6 14,9 42,4 0,18 3,4 RDS56WL max 5600 32,3 46,3 0,33 14,7 34,5 36,1 0,42 23,0 min 2700 15,6 33,4 0,10 1,7 22,1 42,2 0,27 9,9 RDS65WL max 6500 37,5 42,0 0,33 17,9 43,2 37,6 0,52 44,6 min 3100 17,9 30,8 0,11 2,4 27,1 43,7 0,33 18,2 11

Output charts water Type Fan position Airflow Supply water temperature: 60 Room temperature: +18 Outlet air temperature: +35 * 1 Output Return water temp. [] Water flow Pressure drop Water temperature: 60/40 Room temperature: +18 Output* 2 Outlet Water air temp. flow Pressure drop [m 3 /h] [kw] [l/s] [kpa] [kw] [] [l/s] [kpa] RDS23WL max 2300 13,3 51,9 0,40 35,5 10,3 31,3 0,12 3,9 min 1050 6,1 37,9 0,07 1,2 6,4 36,0 0,08 1,6 RDS29WL max 2900 13,8 46,9 0,26 15,0 11,7 29,9 0,14 5,0 min 1300 7,5 40,9 0,10 2,3 7,3 34,6 0,09 2,1 RDS38WL max 3800 21,9 51,5 0,63 36,4 17,3 31,4 0,21 4,5 min 1800 10,4 37,8 0,11 1,4 11,0 36,0 0,13 1,9 RDS56WL max 5600 32,3 52,0 1,05 136 25,5 31,4 0,31 13,1 min 2700 15,6 37,7 0,17 4,3 16,4 35,9 0,20 5,7 RDS65WL max 6500 37,1 48,0 0,72 83,2 32,0 32,5 0,39 25,4 min 3100 17,9 34,9 0,17 5,5 20,2 37,2 0,24 10,5 Type Fan position Airflow Supply water temperature: 55 Room temperature: +18 Outlet air temperature: +32 Output Return water temp. [] Water flow Pressure drop Water temperature: 55/35 Room temperature: +18 Output* 2 Outlet Water air temp. flow Pressure drop [m 3 /h] [kw] [l/s] [kpa] [kw] [] [l/s] [kpa] RDS23WL max 2300 11,2 46,0 0,30 20,9 8,4 28,7 0,10 2,7 min 1050 5,2 35,0 0,06 1,1 5,2 32,6 0,06 1,1 RDS29WL max 2900 14,1 50,0 0,76 124,2 9,5 27,7 0,11 3,4 min 1300 6,4 37,0 0,09 1,9 6,0 31,5 0,07 1,4 RDS38WL max 3800 18,7 46,0 0,50 24,0 14,1 28,9 0,17 3,1 min 1800 8,6 34,0 0,10 1,1 9,0 32,7 0,11 1,3 RDS56WL max 5600 27,2 46,0 0,73 68,5 20,9 29,0 0,25 9,1 min 2700 12,5 32,0 0,13 2,8 13,5 32,8 0,16 4,0 RDS65WL max 6500 31,0 42,0 0,56 50,8 26,4 30,0 0,32 17,6 min 3100 14,4 30,0 0,14 3,8 16,7 33,9 0,20 7,4 * 1 ) Recommended outlet air temperature for good comfort and optimized output. * 2 ) Nominal output at given supply and return water temperature. See www.frico.se for additional calculations. 12

Technical specifications Ambient, no heat - RDS A 1 Type Output Airflow* 1 Electrical heat - RDS E 3 Type Output steps [kw] Airflow* 1 Sound level* 2 [db(a)] t *3 Sound level* 2 [db(a)] Voltage Amperage Voltage [V] Amperage [A] (control) Length [kw] [m 3 /h] [V] [A] [mm] [kg] RDS23A 0 1050/2300 60 2,3 1000 80 RDS29A 0 1300/2900 61 3,6 1000 100 RDS38A 0 1800/3800 62 4,8 1500 150 RDS56A 0 2700/5600 63 7,0 2000 200 RDS65A 0 3100/6500 64 8,2 2500 220 Voltage [V] Amperage [A] (heat) Length Weight* 6 [m 3 /h] [] [mm] [kg] RDS23E08 2,7/5,4/8,1 1050/2300 23/11 60 /2,3 400V3~/11,7 1000 80 RDS29E12 3,9/7,8/11,7 1300/2900 27/12 61 /3,6 400V3~/16,9 1000 100 RDS38E18 6,0/12,0/18,0 1800/3800 30/14 62 /4,8 400V3~/26,0 1500 150 RDS56E23 7,8/15,6/23,4 2700/5600 26/12 63 /7,0 400V3~/33,8 2000 200 RDS65E30 9,9/18,8/29,7 3100/6500 29/14 64 /8,2 400V3~/42,9 2500 220 Weight* 6 Water heat - RDS WL, coil for low water temperature (480 ) 2 Type Output* 4 Output* 5 Airflow* 1 t *3,4 t *3,5 Water Sound Voltage Amperage Length Weight *6 volume level* 1 [kw] [kw] [m 3 /h] [] [] [l] [db(a)] [V] [A] [mm] [kg] RDS23WL 10,3 17,9 1050/2300 18/13 31/23 2,2 60 2,3 1000 80 RDS29WL 11,7 20,4 1300/2900 17/12 29/21 2,2 61 3,6 1000 100 RDS38WL 17,3 29,8 1800/3800 18/13 31/23 3,4 62 4,8 1500 150 RDS56WL 25,5 43,3 2700/5600 18/13 30/23 4,5 63 7,0 2000 200 RDS65WL 32,0 54,1 3100/6500 19/15 32/25 5,7 64 8,2 2500 220 * 1 ) Lowest/highest airflow of totally 5 fan steps. * 2 ) Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m². * 3 ) t temperature rise of passing air at maximum heat output and lowest/highest airflow. * 4 ) Applicable at water temperature 60/40, air temperature, in +18. * 5 ) Applicable at water temperature 80/60, air temperature, in +18. * 6 ) Approximate weight for air curtain and duct. The data are estimated average values which are affected by the shape of the exhaust duct. Protection class: IP20. CE compliant. 13

NO Monterings- og bruksanvisning Generelle anvisninger Les disse anvisningene nøye før installasjon og bruk. Ta vare på disse anvisningene for senere bruk. Produktet må kun brukes som beskrevet i monterings- og bruksanvisningen. Garantien gjelder kun hvis produktet brukes til det som det er beregnet på, og i henhold til anvisningene. Bruk RDS brukes som beskyttelse i karuselldører. Luftporten er tilgjengelig med elektrisk varme og med vannbatteri. Luftporten monteres over døren, og avtrekkskanalen tilpasses dørens diameter, slik at du får en pen og diskré løsning. Kapslingsklasse: IP20. Drift Luften suges inn fra apparatets overside og blåses ut nedover slik at den skjermer døråpningen og reduserer varmetapet. For å oppnå best mulig virkning må apparatet dekke hele åpningens bredde. Luftportens yteevne er avhengig av lufttemperaturen, trykkforskjeller over døråpningen og eventuelt vindtrykk. NB! Undertrykk i bygningen reduserer luftportens yteevne betydelig. Ventilasjonen bør derfor være balansert.. Montering Luftporten monteres horisontalt på taket av svingdøren, på stålplater (100 x 200 mm) som fordeler vekten. Enheten kan alternativt bli montert på bjelker. Sørg for at luftporten med kanal får plass over svingdøren. Avstanden mellom tak på karuselldør og fast innertak i bygningen bør ikke være på mindre enn 800 mm, for at installasjon og service skal være mulig. Sørg for at taket på svingdørens har kapasitet til luftport og kanal. Installasjonens totalvekt er angitt under tekniske data. Hvis karuselldørens tak ikke tåler vekten, kan RDS holdes oppe av en bjelkekonstruksjon. Leveres med bjelkefester. Montering på bjelke, se fig. 2. Elektrisk installasjon Installasjonen skal kobles til en allpolig bryter med minst 3 mm kontaktavstand og kan kun utføres av en godkjent elektriker i henhold til gjeldende IEE-regulativer. Styresystemet forhåndsinstalleres i luftporten med et integrert styrekort. SIRe leveres forhåndsprogrammert med hurtigkoblinger. Modulærkabler kobles til styrekortet. Se håndbok for SIRe. Aggregat med vannbåren varme Tilkobles via det innebygde styrekortet SIRe med 2 m ledning og støpsel. Aggregat med elvarme Tilkobling gjøres på siden av aggregatet. Styrespenning (230 V~) og effektspenning for varme (400 V3~) skal kobles til en koblingsplint. Se Fig.1. Den største kabeldiameteren for koblingsplinten er 16 mm². Benyttede kabelgjennomføringer må oppfylle kravene til kapslingsklasse. I gruppesentralen skal det angis at "luftportene kan forsynes med strøm fra mer enn én tilkobling". Se koblingsskjemaer. 1. Betjeningsluken åpnes ved å skru ut skruene øverst på enheten. 2. Enheten tilkobles via kabelmuffen på høyre side (sett fra innsiden). Se koblingsskjemaer. Type Effekt [kw] Spenning [V] Minsteareal [mm 2 ] Regulering - 1,5 RDS23E08 8,1 400V3~ 2,5 RDS29E12 11,7 400V3~ 4 RDS38E18 18,0 400V3~ 10 RDS56E23 23,4 400V3~ 10 RDS65E30 29,7 400V3~ 16 21

NO RDS Oppstart (E) Når apparatet brukes for første gang eller etter et lengre opphold, kan det komme røyk eller lukt fra støv eller smuss som har samlet seg på elementene. Dette er helt normalt og forsvinner etter en liten stund. Tilkobling av vannbatteriet (W) Installasjonen må utføres av en autorisert installatør. Vannbatteriet har kobberrør med flenser av aluminium og er beregnet for tilkobling til et sluttet vannoppvarmingssystem. Vannbatteriet må ikke kobles til et hovedtrykkvannssystem eller et åpent vannsystem. Vær oppmerksom på at tilkoblingen av apparatet skal skje via reguleringsventil, se Fricos ventilsett. Vannbatteriet kobles til på siden av aggregatet via innvendig gjengede rør DN25 (1 ). Fleksible slanger fås som tilbehør, se tilbehørssider. Legg merke til at ved montering av rørkobling skal de sekskantede tilkoblinger holdes fast med et verktøy slik at koblingen ikke skades. Koblingene til vannbatteriet må utstyres med avstengingsventiler (følger ikke med), slik at det lett kan stenges av. En lufteventil skal tilkobles ved et høyt punkt i rørsystemet. Luftventiler følger ikke med. Innstilling av viftehastighet Viftehastighet når døren er åpen, stilles inn ved hjelp av regulatoren. Vær oppmerksom på at luftstrømmens retning og viftehastigheten kan trenge finjustering, avhengig av belastningen på døren. Filter (W) Batteriets lamellavstand i kombinasjon med hulldiameteren i innsugingsgitteret beskytter mot tilskitning og gjentetting. Derfor er det vanligvis overflødig med et separat filter. Service, reparasjon og vedlikehold Gjør følgende før du utfører service, reparasjon og vedlikehold: 3. Koble fra strømtilførselen. 4. Serviceluken åpnes ved å løsne skruene på aggregatets side. Vedlikehold Apparat med vannbåren varme: Filteret i apparatet må rengjøres regelmessig for å ivareta luftportvirkningen og varmeutstrålingen fra apparatet. Hvor ofte, avhenger av lokale forhold. Et tiltettet filter er ikke en risiko, men det kan oppstå funksjonsfeil. Støvsug innsugingsgitteret regelmessig fra utsiden når støv er synlig, for eksempel som en del av vaskerutinen. Alle apparater: Fordi viftemotorene og andre komponenter er vedlikeholdsfrie, er det ikke nødvendig med annet vedlikehold enn rengjøring. Rengjøringsnivået kan variere, avhengig av lokale forhold. Rengjør minst to ganger per år. Innblåsnings- og utblåsningsgitter, viftehjul og elementer kan støvsuges eller tørkes rene med en fuktig klut. Bruk en børste når du støvsuger for å unngå skader på ømfintlige deler. Ikke bruk sterke alkaliske eller syreholdige rengjøringsmidler. Overoppheting Luftporten med elektrisk varme er utstyrt med overopphetingsvern. Hvis det utløses på grunn av overoppheting, tilbakestiller du det slik: 5. Koble fra strømmen med den isolerte bryteren. 6. La det elektriske batteriet få kjøle seg ned. 7. Finn årsaken til overopphetingen og rett opp feilen. 8. Koble til luftporten igjen. Alle motorer er utstyrt med en innebygd termokontakt. Denne settes i funksjon og stopper luftporten hvis temperaturen i motoren blir for høy. Termokontakten tilbakestilles automatisk når motortemperaturen har kommet tilbake til normale verdier igjen. Temperaturkontroll Temperaturreguleringen for SIRe opprettholder utblåsningstemperaturen. Hvis temperaturen skulle bli enda høyere, høres en overopphetingsalarm. For mer informasjon se håndboken for SIRe. 22

NO Uskifting av viften Viftene byttes ut gjennom betjeningsluken i bunnen. Alternativt kan man løsne skruene til betjeningsluken i bunnen og bytte ut viftene gjennom betjeningsluken på toppen. 9. Finn ut hvilken av viftene som ikke virker. 10. Koble fra ledningene til den aktuelle viften. 11. Fjern skruene som holder fast viften, og løft viften ut. 12. Monter den nye viften som forklart ovenfor, men i omvendt rekkefølge. Utskifting av et elektrisk batteri/varmepakke (E) Vannbatteriet må byttes ut via betjeningsluken i toppen. 13. Merk og koble fra kablene til varmeelementene/-pakken. 14. Fjern festeskruene som holder varmeelementene/-pakken fast i enheten, og løft varmeelementene/-pakken ut. 15. Installer de/den nye varmeelementene/- pakken i motsatt rekkefølge i forhold til ovenfor. Feilsøking Hvis viftene ikke virker eller ikke blåser tilstrekkelig, sjekk følgende: At innsugningsgitteret/-filteret ikke er skittent. Kontroller funksjonene og innstillingene for styresystemet SIRe, se håndbok for SIRe. Hvis det ikke er noe varme, må du kontrollere følgende: Kontroller funksjonene og innstillingene for styresystemet SIRe, se håndbok for SIRe. For apparater med elektrisk varme må også følgende sjekkes: Strømtilførselen til det elektriske batteriet: kontroller sikringer og strømbryter (hvis det finnes en). At overopphetingsbeskyttelsen for motoren ikke er utløst. For apparater med vannbatteri må følgende også sjekkes: At vannbatteriet er tømt for luft. At vannmengden er tilstrekkelig. At innkommende vann er nok oppvarmet. Hvis feilen ikke kan rettes opp, må du kontakte en kvalifisert servicetekniker. Strømbryter for reststrøm (E) Hvis installasjonen er beskyttet med en strømbryter for reststrøm, og denne utløses når apparatet kobles til, kan årsaken være fuktighet i varmeelementet. Når et apparat som inneholder et varmeelement ikke har vært brukt over lengre tid eller oppbevares i et fuktig miljø, kan det trenge fuktighet inn i elementet. Dette er ikke en feil, men en situasjon som du enkelt retter opp ved å koble apparatet til strømforsyningen via en kontakt uten jordfeilbryter, slik at fuktigheten får trekke ut av elementet. Tørketiden kan variere fra noen timer til et par dager. Som et forebyggende tiltak bør apparatet innimellom tas i bruk i kortere perioder når det ikke skal brukes over lengre tid. Sikkerhet For alle installasjoner av elektrisk oppvarmede produkter skal det benyttes en 300 ma strømbryter for reststrøm av hensyn til brannsikkerheten. Sikre at området rundt apparatets innsugog utblåsgitter holdes fri fra materiell som kan hindre luftstrømmen gjennom apparatet! Enhetens ytterside kan være varm når den er i drift, og i tiden etter at den er slått av. Enheten må ikke tildekkes, verken helt eller delvis, av tekstiler eller liknende materialer. Overoppheting kan føre til brannfare! (E) Bruk løfteutstyr ved løfting av enheten. Dette apparatet kan brukes av barn på 8 år eller eldre, samt personer med nedsatte fysiske, sansemessige eller psykiske evner, eller med manglende erfaring og kunnskap, under den forutsetning at de holdes under oppsikt eller har fått opplæring i sikker bruk av apparatet, og er inneforstått med faremomentene. Barn skal ikke leke med apparatet. Rengjøring og vedlikehold skal ikke utføres av barn uten tilsyn. 23

NO RDS Oversettelse av introduksjonssidene Top view Side view Suspended from ceiling Mounted on revolving door Connections position Accessories Beam Wiring diagrams for xxx, see manual for xxx. Fra toppen Fra siden Opphengt i taket Montert på svingdør Tilkobling Tilbehør Bjelke Koblingsskjemaer for xxx og xxx, se håndbok for SIRe. Tekniske data Output steps [kw] Output* 4, 5 [kw] Airflow* 1 [m3/h] Sound level* 1 [db(a)] Voltage motor [V] Amperage motor [A] Voltage / Amperage heat Water volume [l] Length [mm] Weight* 6 [kg] Effekttrinn Effekt Luftmengde Lydnivå Spenning motor Strøm motor Spenning / Strøm varme Vannvolum Lengde Vekt * 1 ) Lavest/høyest luftmengde av totalt 5 viftetrinn. * 2 ) Betingelser: Avstand til aggregat 5 meter. Retningsfaktor: 2. Ekvivalent absorpsjonsareal: 200 m². * 3 ) t temperaturøkning på gjennomstrømmende luft ved maksimal varmeeffekt og lav/høy luftmengde. * 4 ) Gjelder ved vanntemperatur 60/40, lufttemperatur inn +18. * 5 ) Gjelder ved vanntemperatur 80/60, lufttemperatur inn +18. * 6 ) Omtrentlig vekt for luftport og kanal. Dataene er beregnede gjennomsnittsverdier som påvirkes av formen på avtrekkskanalen. CE-merket. Dimensjoneringstabeller Supply water temperature [] Room temperature [] Outlet air temperature* 1 [] Water temperature [] Fan position Airflow [m 3 /h] Output* 2 [kw] Return water temperature [] Water flow [l/s] Pressure drop [kpa] Turvanntemperatur Romtemperatur Utslippslufttemperatur Vannvolum Vifteregulering Luftmengde Effekt Returvanntemperatur Vannmengde Trykkfall * 1 ) Anbefalt utslippslufttemperatur for god komfort og optimal ytelse. * 2 ) Nominell effekt ved oppgitt tur- og returvanntemperatur. 24

Art.nr: 208029, 160705, SL