AD Corinte W - ADCS

Like dokumenter
Thermozone AD Corinte W - ADCS

Thermozone AD Corinte W - ADCS

Elektra H GB... 9 NO

Elektra V GB NO DE PL

Elektra F GB NO FR

Original instructions RDS

Original instructions AR

Comfortinfra CIR11021C

Original instructions Elztrip EZ W

IR3000, IR4500, IR6000

Original instructions. Thermozone ADA Cool RU

Original instructions RDS

Original instructions. Panther 6-15 kw

Original instructions. Panther 6-15 kw

Original instructions CAT

Original instructions. Thermoplus

Elztrip EZ

Original instructions. Comfortinfra CIR DE NL FI RU... 20

Thermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18

Original instructions CIR DE NL FI RU... 20

Original instructions. SIRe Basic Quick guide. SIReB

Original instructions. Infrared heater IRCF

Original instructions PA2500

Original instructions AGS5500

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 1 Uten varme 3 Elvarme: 8 30 kw 2 Vannbåren varme WL.

Original instructions AR

Elztrip EZ

Original instructions PA2500

Original instructions. Thermoplus

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 3 Elvarme: 8 30 kw 2 Vannbåren varme WL. For svingdører

Elektra C GB NO

Original instructions AR

Original instructions. Infrared heater IRCF...17

PA2500 PA2500E. Elegant luftport for inngangspartier, med intelligent regulering. 1 Uten varme 3 Elvarme: 5-16 kw 2 Vannbåren varme

AGS5500 AGS5500. Luftport for dør/port i industrilokaler og store lokaler, med intelligent styresystem. 1 Uten varme 2 Vannbåren varme WH, WL

SFS SFS. Designluftport for svingdører, med intelligent regulering. 3 Elvarme: 8 23 kw 2 Vannbåren varme WL. For svingdører

Original instructions AR

PA2500W PA2500E. Elegant luftport for inngangspartier, med intelligent regulering. 3 Elvarme: 5-16 kw 2 Vannbåren varme

Thermocassette HP SE... 6 GB... 8 NO FR DE FI RU... 18

Original instructions. Thermocassette HP

Corinte Designluftport for eksklusive inngangspartier, med intelligent regulering

AR200 AR200. Innfelt luftport for små innganger. 1 Uten varme 3 Elvarme: 3 18 kw 2 Vannbåren varme. Anbefalt installasjonshøyde 2,5 m*

Original instructions AR

AD Corinte. Thermozone AD Corinte. Luftporter for dører med høyde på opptil 3 meter

Original instructions. SIRe Basic Air Curtains Water With quick guide. SIReB. For wiring diagram, please see last pages

Corinte Designluftport for eksklusive inngangspartier, med intelligent regulering

Original instructions SFS

AGS5000 AGS5000. Luftport for dør/port i industrilokaler og store lokaler, med intelligent styresystem. 1 Uten varme 2 Vannbåren varme WH, WL

AGI AGI. Solid luftport for store industridører. 1 Uten varme 2 Vannbåren varme WL. Horisontal og vertikal montering

Original instructions PA1508 NO DE ES

Infraduo IHD17 IHD

Original instructions PA

Thermozone AGV 4000 A/E/W

Elztrip EZ 300. Elztrip EZ300. Trepanels varmestråler for lagre, verksteder og lignende

Comfort control IHBD3

Original instructions. SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see last pages

RDS RDS. Diskré luftport for svingdører, med intelligent regulering. 1 Uten varme 3 Elvarme: 8 30 kw 2 Vannbåren varme WL.

Installasjon anvisning. Tak kassett Split System luftkjøler

Corinte. Corinte. Designluftport for eksklusive inngangspartier, med intelligent regulering. Anbefalt installasjonshøyde 3 m*

Original instructions SFS

VLSP TAC SD230 AV BPV10 SD230 TAC BPV10

Kjøkkenventilator 761 Opal

SIRe Basic Fan Heaters Water With quick guide SIReB

Noah Wall Heater Art. Nr:

Corinte. Corinte. Designluftport for eksklusive inngangspartier, med intelligent regulering. Anbefalt installasjonshøyde 3 m*

AR200 AR200. Innfelt luftport for små innganger. 1 Uten varme 3 Elvarme: 3 18 kw 2 Vannbåren varme. Anbefalt installasjonshøyde 2,5 m*

Original instructions. SIRe Basic Fan Heaters Water With quick guide. SIReB. For wiring diagram, please see last pages.

Thermozone SF. Luftporter for vertikal montering i svingdører

Original instructions. SIRe Basic Fan Heaters Electric With quick guide. SIReBX. For wiring diagram, please see last pages.

DK: ADVARSEL! bruges i horisontal position. Må ikke tildækkes eller bruges i nærheden af letantændeligt materiale, da dette kan medføre brandfare.

t* 3 Lydnivå* 2 [ C] [db(a)]

Styresystem SIRe. Intelligent Tilpasser seg automatisk inngangen. Proaktiv funksjon Gir raskere reaksjon

Luftporter ELiS B. Egenskaper. Dimensjoner JUSTERBARE LAMELLER RADIAL VIFTE BMS KONTROLL SYSTEM ENKEL KONSTRUKSJON

mars 2017 MONTERINGS OG BRUKSANVISNING Ecosun GS ELFLEX GLASS STRÅLEPANEL FOR VEGG & TAK

Varmluftsvifter SWT. Varmluftsvifter SWT. Takmontert varmevifte med vannbåren varme

UF600 UF600. Luftport for bruk med utblåsingåpning under gulvet i store industriporter/dører. For dører opptil (H x B): 6 x 12 m

Varmluftsvifter SWH. Varmluftsvifter SWH. Intelligent varmevifte med ekstremt lavt lydnivå, for vanntilkobling. Produktspesifikasjoner

Halogen infraovn Thermo THI 1500

Elektra F GB NO FR

ELZTRIP EZF8-21 PL NO... 8 FR IT GB RU... 20

PA2200C PA2200C. Elegant luftport for inngangspartier, med fjernkontroll og integrert regulering. 1 Uten varme 3 Elvarme: 3 16 kw 2 Vannbåren varme

Thermozone AG4000 A/E/W Luftporter for entrèer eller porter med høyde opp til 4 meter

Original instructions AGI4500/6000

Varmluftsvifte SW02 Stillegående varmevifte for tilkobling til vann i små bygninger.

Montering og bruksanvisning.

VC300 Operating Instructions

HÅNDBOK. Bruksanvisning terrassevarmer TV TV 2100 frittstående modell

Skotørker DF-ST001 Brukerhåndbok KUN TIL HJEMMEBRUK MÅ VÆRE MONTERT TIL VEGG

Relivent Monteringsveiledning. Tekniske data:

BRUKSANVISNING FOR TERMOELEKTRISK VINKJØLER

Varmluftsvifte Tiger Robust varmevifte for bærbar bruk i krevende miljøer.

Opptiningsskap Tina 180 Installeringsanvisning

SP120 SP220 SP320 SP /19235/0 - Issue 0

Kjøkkenhette NO Bruksanvisning

Din bruksanvisning HUSQVARNA QC900U

EVB er testet av INTERTEK SEMKO, IP44, og kan normalt benyttes i tørre-, fuktige-, og våte rom.

Original instructions PAEC3200 NO DE ES

PA3500/4200 PA3500/4200. Elegant luftport for forretnings- og industrilokaler, med intelligent regulering

Vedlikeholdsmanual Tørketrommel

Infrasmart IHS20W/B/S24

Transkript:

SE...16 GB...19 NO...22 FR...25 RU...28 DE...31 NL...34 ES...37 PL...40 FI...43 IT...46 DK...49

Min 180 M8 M8 VL - A VR - A VL - B VR - B Min 180 225 125 Cu ø22 72 116 72 116 225 125 Fig 1 Wall Wall Doorway Top Top Bottom (seen from above) Bottom (seen from above) 2

2 Fig 2 Fig 3 1 Ø22 Cu 2 Ø22 Cu 1 3 80 60 PH2 / 1/4 60 80 2200/2450 500 350 3

6 1 2 3 B A C 5 7 8 10 9 4 Fig 4 4

Fig 5 5

1700/2200 1670/2170 100 126 75 Left connection Wall Right connection Ø31.5 (2x) Ø20 (3x) Fig 6a 75 Min 180 mm 50 Min 180 mm 376 Fig 6b 6

243 AD Corinte W - ADCS ø12 Fig 6c Fig 6d 360 Ø10 Ø22 5 10 15 35 80 35 180 25 40 Fig 7 7

ADCEH Ø8 Ø12 (2x)} 2 alternatives for securing at the top.* 1 A B C Ø8 for securing at the air curtain.* 2 A B SE / NO / FR / RU / DE / NL / ES / PL / FI / IT / DK C * 1 ) 2 alt. för stagning i toppen. / 2 muligheter for montering på toppen. / 2 possibilités de fixation par le haut. / 2 варианта крепления верхней части / Zwei Befestigungsmöglichkeiten an der Oberseite / 2 alternatieven voor bevestiging aan de bovenkant. / 2 opciones de sujeción a la parte superior. / 2 opcje montażu w części górnej. / 2 vaihtoehtoista kiinnitystapaa. / 2 alternative per il montaggio sulla parte superiore. / 2 alternativer til fastgørelse foroven. * 2 ) Ø8 för stagning i luftridån. / Ø8 for montering på luftporten. / Ø8 pour fixation du rideau d air. / Для крепления к завесе / Ø 8 zur Befestigung am Luftschleier / Ø8 voor bevestiging aan het luchtgordijn. / Ø8 para sujeción a la cortina de aire. / Ø8 do zamocowania kurtyny powietrznej. / Ø8 ilmaverhokojeen kiinnitykseen. / Ø8 per il montaggio sulla barriera d aria. / Ø8 til fastgørelse af lufttæppet. 8

ADCS - SIRe Fig 8 SIRe 9

C AD Corinte W - ADCS SIRe SIReB SIReAC SIReAA SIReRTX 70x33x23 mm SIReUR 114x70x50 mm SIReWTA SIReCJ4 SIReCJ6 SIReCC603 3 m SIReCC605 5 m SIReCC610 10 m SIReCC615 15 m SIReCC640 40 m SIReCC403 3 m SIReCC405 5 m SIReCC410 10 m SIReCC415 15 SIReB SIReAC/SIReAA SIReUR SIReWTA SIReCJ4/SIReCJ6 SIReRTX SIReCC VKF15LF VKF15NF VKF20 VKF25 VKF32 SD230 BPV10 SDM24 ST23024 DN15 DN15 DN20 DN25 DN32 VLSP VKF SD230 BPV10 VLP VKF SDM24 ST23024 10

Wiring diagrams Internal wiring diagram ADCS W 230V~ SIReB1 C2 C1 ROOM Internal sensor Motor protection 230V 200V 170V 145V 120V 100V N Transformer Yellow 230V Orange 200V Red 170V Brown 145V Black 120V Green 100V Blue N Transformer Blue Black Actuator 230V~ Supply 230V~ N L 230V~ 11

Wiring diagrams SIRe B Basic SIReB1/B2/B1EC 230V~ SD230 SIReRTX (optional) SIReUB1 Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L L PE N L ~ SIReCC6XX (max 50 m) L=2m L=1,5m SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~ Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L L PE N L ~ SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~ Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L L PE N L ~ Wiring diagrams for SIReAC Competent and SIReAA Advanced, see manuals for SIRe. 12

ADCS WH Type Fan position Air Supply water temperature: 110 C Outlet air temperature: +35 C* 1 Return water temp. temperature: 110/80 C * 2 Outlet air temp. [m 3 /h] [kw] [l/s] [kpa] [kw] [l/s] [kpa] ADCS17WH max 3200 18,7 36 0,06 0,5 39,6 54,2 0,33 8 min 1500 9,3 35 0,03 0,1 24 64,9 0,20 3,3 ADCS22WH max 4400 24,8 33 0,08 0,9 52,4 52,9 0,43 16,5 min 2100 12,0 29 0,04 0,2 32,7 63,6 0,27 7,1 ADCS25WH max 5000 28,7 32 0,09 1,2 61,6 54,1 0,51 24,3 min 2400 13,6 27 0,04 0,3 38,2 64,6 0,31 10,3 Type Fan position Air Supply water temperature: 90 C Outlet air temperature: +35 C* 1 Return water temp. temperature: 90/70 C * 2 Outlet air temp. [m 3 /h] [kw] [l/s] [kpa] [kw] [l/s] [kpa] ADCS17WH max 3200 18,1 39 0,09 0,8 32 47,3 0,39 11,7 min 1500 8,7 35 0,04 0,2 19,3 55,8 0,24 4,7 ADCS22WH max 4400 25,5 39 0,12 1,9 42,3 46,2 0,52 24,1 min 2100 12,0 31 0,05 0,4 26,3 54,7 0,32 10,2 ADCS25WH max 5000 28,8 36 0,13 2,4 49,7 47,1 0,61 35,4 min 2400 14,2 30 0,06 0,6 30,7 55,5 0,38 14,9 Type Fan position Air Supply water temperature: 80 C Outlet air temperature: +35 C* 1 Return water temp. temperature: 80/60 C * 2 Outlet air temp. [m 3 /h] [kw] [l/s] [kpa] [kw] [l/s] [kpa] ADCS17WH max 3200 18,7 42 0,12 1,5 26,3 42,1 0,32 8,5 min 1500 8,7 35 0,05 0,3 16 49,2 0,20 3,5 ADCS22WH max 4400 25,8 42 0,17 3,4 35 41,3 0,43 17,5 min 2100 12,0 33 0,06 0,6 21,8 48,4 0,27 7,5 ADCS25WH max 5000 29,3 40 0,18 4,3 41,2 42,1 0,50 25,7 min 2400 14,0 32 0,07 0,8 25,5 49,1 0,31 10,9 Type Fan position Air Supply water temperature: 82 C Outlet air temperature: +35 C* 1 Return water temp. temperature: 82/71 C * 2 Outlet air temp. [m 3 /h] [kw] [l/s] [kpa] [kw] [l/s] [kpa] ADCS17WH max 3200 19,0 42 0,12 1,4 30,8 46,2 0,69 32,6 min 1500 8,8 35 0,05 0,3 18,5 54,1 0,41 12,9 ADCS22WH max 4400 26,2 42 0,16 3,1 40,5 45 0,90 66,6 min 2100 12,2 33 0,06 0,6 25,1 53 0,56 27,8 ADCS25WH max 5000 28,4 38 0,16 3,4 47,5 45,8 1,06 97,6 min 2400 13,7 31 0,06 0,7 29,2 53,6 0,65 40,2 * 1 ) Recommended outlet air temperature for good comfort and optimized output. * 2 ) Nominal output at given supply and return water temperature. 13

ADCS WL Type Fan position Air Supply water temperature: 80 C Outlet air temperature: +35 C* 1 Return water temp. temperature: 80/60 C * 2 Outlet air temp. [m 3 /h] [kw] [l/s] [kpa] [kw] [l/s] [kpa] ADCS17WL max 3200 18,3 33 0,09 0,9 35,8 50,8 0,44 12,6 min 1500 8,9 31 0,04 0,2 21 59 0,26 4,8 ADCS22WL max 4400 26,1 31 0,13 1,8 50,1 51,4 0,61 28,5 min 2100 12,0 27 0,05 0,4 29,7 59,4 0,36 11 ADCS25WL max 5000 28,2 29 0,13 2,2 57,3 51,6 0,70 39,6 min 2400 14,0 26 0,06 0,6 34,1 59,6 0,42 15,4 Type Fan position Air Supply water temperature: 70 C Outlet air temperature: +35 C* 1 Return water temp. temperature: 70/50 C * 2 Outlet air temp. [m 3 /h] [kw] [l/s] [kpa] [kw] [l/s] [kpa] ADCS17WL max 3200 18,5 35 0,13 1,5 28,2 43,8 0,34 8,4 min 1500 8,9 32 0,06 0,4 16,6 50,4 0,20 3,2 ADCS22WL max 4400 26,2 33 0,17 3,1 39,7 44,4 0,48 19,1 min 2100 12,5 28 0,07 0,7 23,6 51 0,29 7,5 ADCS25WL max 5000 28,8 32 0,18 3,8 45,5 44,6 0,55 26,6 min 2400 13,7 27 0,08 0,9 27,2 51,2 0,33 10,6 Type Fan position Air Supply water temperature: 60 C Outlet air temperature: +35 C* 1 Return water temp. temperature: 60/40 C * 2 Outlet air temp. [m 3 /h] [kw] [l/s] [kpa] [kw] [l/s] [kpa] ADCS17WL max 3200 18,7 37 0,20 3,4 20,4 36,6 0,25 4,8 min 1500 8,8 32 0,08 0,6 12,1 41,5 0,15 1,9 ADCS22WL max 4400 24,9 35 0,24 5,7 29,1 37,4 0,35 11,2 min 2100 12,0 30 0,10 1,2 17,5 42,4 0,21 4,5 ADCS25WL max 5000 28,9 35 0,28 8,1 33,5 37,6 0,41 15,8 min 2400 14,3 30 0,11 1,7 20,2 42,6 0,24 6,4 Type Fan position Air Supply water temperature: 55 C Outlet air temperature: +35 C* 1 Return water temp. temperature: 55/35 C * 2 Outlet air temp. [m 3 /h] [kw] [l/s] [kpa] [kw] [l/s] [kpa] ADCS17WL max 3200 18,9 39 0,3 6,5 16,3 32,9 0,20 3,3 min 1500 8,6 32 0,1 0,9 9,7 36,9 0,12 1,3 ADCS22WL max 4400 25,2 37 0,3 10,6 23,6 33,8 0,29 7,9 min 2100 12,4 31 0,1 1,9 14,2 37,9 0,17 3,2 ADCS25WL max 5000 29,0 37 0,4 15,0 27,3 34 0,33 11,2 min 2400 13,9 30 0,1 2,3 16,5 38,2 0,20 4,6 * 1 ) Recommended outlet air temperature for good comfort and optimized output. * 2 ) Nominal output at given supply and return water temperature. 14

Technical specifications 2 heat - ADCS WH, coil for high temperature water ( 80 C) (IP20) Type * 6 [kw] Air* 3 [m 3 /h] t* 5,6 volume [l] Sound level* 4 [db(a)] motor [W] Voltage motor [V] Amperage motor [A] Length ADCS17WH*¹ 26 1500/3200 31/24 2,8 43/61 890 230V~ 3,9 1700 85 ADCS22WH 35 2100/4400 30/23 3,6 44/62 1230 230V~ 5,4 2200 110 ADCS25WH*² 41 2400/5000 31/24 4,0 45/63 1420 230V~ 6,2 2450 125 [mm] Weight [kg] 2 heat - ADCS WL, coil for low water temperature (<80 C) (IP20) Type * 7 [kw] Air* 3 [m 3 /h] t* 5,7 volume [l] Sound level* 4 [db(a)] motor [W] Voltage motor [V] Amperage motor [A] Length ADCS17WL*¹ 20 1500/3200 23/18 2,8 43/61 890 230V~ 3,9 1700 85 ADCS22WL 29 2100/4400 24/19 3,6 44/62 1230 230V~ 5,4 2200 110 ADCS25WL*² 33 2400/5000 24/19 4,0 45/63 1420 230V~ 6,2 2450 125 [mm] Weight [kg] * 1 ) Available only for horizontal mounting. * 2 ) Available only for vertical mounting. * 3 ) Lowest/highest air of totally 5 fan steps. * 4 ) Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m². At lowest/highest air. * 5 ) t = temperature rise of passing air at maximum heat output and lowest/highest air. * 6 ) Applicable at water temperature 80/60 C, air temperature, in +18 C. * 7 ) Applicable at water temperature 60/40 C, air temperature, in +18 C. Protection class: IP20. CE compliant. 15

NO AD Corinte W - ADCS Monterings- og bruksanvisning Generelle anvisninger Les disse anvisningene nøye før installasjon og bruk. Ta vare på denne bruksanvisningen for senere bruk. Garantien er gyldig bare hvis apparatene brukes etter produsentens anvisning og i samsvar med Fricos monterings- og bruksanvisninger. Bruksområde Luftporten AD Corinte W - ADCS W leveres med vannbatteri og er beregnet på fast montering over eller ved siden av inngangsdører og andre åpninger med en høyde på opptil 3,5 meter. Kapslingsklasse: IP20. Funksjon Luften suges inn fra apparatets overside/ bakside og blåses ut nedover/utover slik at den skjermer døråpningen og reduserer varmetapet. For å oppnå best mulig virkning må apparatet dekke hele åpningens høyde/ bredde. Gitteret som bestemmer retningen på ublåsningsluften, kan justeres og er normalt rettet utover for å oppnå best mulig beskyttelse mot innkommende kald luft. Luftportens yteevne er avhengig av lufttemperaturen, trykkforskjeller over døråpningen og eventuelt vindtrykk. NB! Undertrykk i bygningen reduserer luftportens yteevne betydelig. Ventilasjonen bør derfor være balansert. Vertikal montering Apparatet monteres vertikalt på gulvet med utblåsningsåpningen vendt utover. Før installasjon må det tas stilling til hvorvidt tilkobling av elektrisitet eller vann skal gjøres fra undersiden. La beskyttelsesplasten være på under installasjon. Pass på at overflatene ikke skades. For installasjon, se figur 4. 1. Skru ut skruene i frontpanelet. 2. Skru ut skruene som fester frontpanelet til utblåsningsgitteret. 3-4. Fjern frontpanelet. 5. Plasser rammen på gulvet og fest den om nødvendig med bolter eller lignende i de forsenkede hullene (se fig.7). Plasser luftporten på rammen. 6. Den medfølgende flate listen brukes til å feste luftporten. Monter luftporten gjennom det firkantede hullet. Pass på at den flate listen ikke blir bøyd under monteringen. 7. Fest oversiden med en vinkelbrakett eller lignende for å forhindre at luftporten velter. Midt på luftportens overside er det et hull med en innvendig M8-gjenge som braketten kan festes i. Rengjør panelene for smuss og fingeravtrykk med et egnet rengjøringsmiddel. Eventuelle merker på panelene fjernes enkelt med et egnet løsemiddel. Horisontal montering Apparatet monteres horisontalt med utblåsningsåpningen vendt nedover. Ikke fjern beskyttelsesplasten før etter montering. Pass på at overflatene ikke skades. Montering mindre enn 180 mm fra taket anbefales ikke, ettersom det vil redusere luftstrømmen gjennom apparatet. Apparatet leveres med to braketter for montering på vegg eller hengende i taket. Horisontal montering på veggen 1. Monter brakettene på veggen iht. målene i fig. 6a og 6b. 2. Sett apparatet på plass og fest det med en sekskantnøkkel og de medfølgende M8- skruene. Horisontal montering i taket 1. Monter pendler eller lignende (medfølger ikke) i taket med c/c-avstand iht. fig. 6a og 6b. 2. Monter brakettene på apparatet med en sekskantnøkkel og de medfølgende M8- skruene. 3. Sett apparatet på plass og fest brakettene i pendlene. NB! Apparatet må sikres hvis det henger i vaiere. 22

NO Elektrisk installasjon Luftporten leveres med kabel og plugg. Installasjonen skal kobles til en allpolig bryter med minst 3 mm kontaktavstand og kan kun utføres av en godkjent elektriker i henhold til gjeldende IEE-regulativer. Styresystemet er forhåndsinstallert i luftporten med et integrert styrekort (se fig. 8). SIRe leveres forhåndsprogrammert og er utstyrt med hurtigkoblinger. Modulærkabler kobles inn på styrekortet Bas ved å åpne frontplaten, se fig 4 og 5. Se manual for SIRe Tilkobling av vannbatteri Luftporten har et vannbatteri kobberrør som er beregnet for bruk i et lukket vannoppvarmingssystem. Vannbatteriet må ikke kobles til et hovedtrykkvannsystem eller et åpent vannsystem. Enheten kobles til Ø22 mm kobberrør ved lodding eller annen tilfredsstillende kobling. Vannbatteriets overside er utstyrt med lufteventil. Vannbatteriet skal luftes før bruk for å forhindre innestengt luft. Når apparatet monteres vertikalt, kan vannet kobles til fra oversiden eller undersiden. Tilkobling fra undersiden kan gjøres på følgende måte: Fleksible slanger kan trekkes gjennom hull boret i gulvet og kobles til luftportens rør. De fleksible slangene er tilkoblet systemet under gulvet. NB! Ved tilkobling fra undersiden, unngå å plassere slanger eller rør slik at de kan hindre luftstrømmen til viftene. Fest dem om nødvendig for å unngå vibrasjoner og forhindre at de suges inn i viftene. Når apparatet monteres horisontalt, kan vannet tilkobles fra venstre eller høyre. Lokket på apparatets overside kan skyves og på den måten tilpasses vannrørenes dimensjon. (se fig 6a). Luftstrømmen må derfor rettes utover for å stå imot belastningen. (Generelt kan sies at jo større belastning, desto større vinkel er nødvendig.) Løsne de tre skruene som fester utblåsningsgitteret med en sekskantnøkkel. Vinkle gitteret utover for å hindre innkommende kald luft. Overoppheting Overopphetningsvernet i SIRe passer på å begrense utblåsningstemperaturen til 40 C. Om temperaturen allikevel går over, gis et alarm. Les mer i manualen for SIRe Vedlikehold For å opprettholde luftportens ytelse og driftssikkerhet bør den inspiseres regelmessig (minst to ganger i året). Dette kan imidlertid variere avhengig av lokale forhold. Et tett filter innebærer ingen risiko, men vil redusere luftportens effektivitet. Innblåsningsgitteret fungerer som et filter og bør støvsuges regelmessig. Vannbatteriet bør rengjøres ved behov på følgende måte: 1. Koble fra strømtilførselen. 2. Løsne de to skruene på innblåsningsgitteret med en sekskantnøkkel og fjern gitteret. 3. Tørk forsiktig av varmebatteriets finner med en våt klut. 4. Monter innsugningsgitteret. 5. Koble til strømmen. Hvis apparatet er utstyrt med filterkassetter, må disse byttes ut når de er skitne eller når luftstrømmen reduseres. De kan ikke rengjøres. Grunnfilteret rengjøres med vann og et mildt rengjøringsmiddel. Viftemotorene og andre komponenter er vedlikeholdsfrie, og det er derfor ikke nødvendig å foreta annet vedlikehold enn rengjøring. Disse bør rengjøres minst to ganger i året. Justering av luftstrøm Luftstrømmens retning og hastighet må justeres i forhold til belastningen på åpningen. Trykkrefter påvirker luftstrømmen slik at den bøyer av innover i lokalet (når lokalene er oppvarmet og uteluften er kald). 23

NO AD Corinte W - ADCS Sikkerhet Sørg for at området rundt apparatets innsugnings- og utblåsnigsgitter til enhver tid er fritt for materialer som kan hindre luftstrømmen gjennom apparatet! Apparatets overflater er varme under drift! Dette apparatet kan brukes av barn på 8 år eller eldre, samt personer med nedsatte fysiske, sansemessige eller psykiske evner, eller med manglende erfaring og kunnskap, under den forutsetning at de holdes under oppsikt eller har fått opplæring i sikker bruk av apparatet, og er inneforstått med faremomentene. Barn skal ikke leke med apparatet. Rengjøring og vedlikehold skal ikke utføres av barn uten tilsyn. 24

Main office Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se Art nr: 208033, 2017-02-28 CH/LE