Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER. HRAT R407c

Like dokumenter
Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER HRAT R22

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER HRAT R22

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED RADIALVIFTER HRA R22

VANN/VANN ISVANNSAGGREGAT HRH R22

VANN/VANN VARMEPUMPE HRHH R22

Fla kt Woods AS VANN/VANN ISVANNSAGGREGAT. HRH R407c

VANN/VANN ISVANNSAGGREGAT HRH R22

Fla kt Woods AS LUFT/VANN VARMEPUMPE MED AKSIALVIFTER HRAN R22

Fla kt Woods AS VANN/VANN VARMEPUMPE MED RADIALVIFTER HRN R22

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER FE-WRAT R22

Fla kt Woods AS LUFTKJ LT ISVANNSAGGREGAT MED FRIKJ LING. WRAT-FC R407c

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER. WRAT R407c

Fla kt Woods AS LUFTKJ LT ISVANNSAGGREGAT MED FRIKJ LING WRAT-FC R22

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER. WRAT R407c

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER WRAT R22

ISVANNSAGGREGAT FOR FJERNKONDENSATOR ME R22

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER WRAT R22

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER. BE/ESRAT R134a

VANN/VANN VARMEPUMPE WRHH R22

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER. BE/SRAT R407c

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER BE/SRAT R22

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED RADIALVIFTER WRA R22

Fla kt Woods AS VANN/VANN ISVANNSAGGREGAT. ERH R134a

BRUKSANVISNING REGULATOR CVM 2

Dx Dx kjø ling. For kondensatorbatteri i avtrekkskanal. Type HE-A. FOREL PIG versjon 3

VANN/VANN ISVANNSAGGREGAT BE-SRH R22

VANN/VANN ISVANNSAGGREGAT WRH R22

Fla kt Woods AS VANN/VANN ISVANNSAGGREGAT. BE-ESRH R134a

Fläkt Klimaprodukter VANN/VANN ISVANNSAGGREGAT. BE-SRH R407c

Fla kt Woods AS VANN/VANN ISVANNSAGGREGAT. WRH R407c

Fla kt Woods AS ISVANNSAGGREGAT FOR FJERNKONDENSATOR. ME R407c

Fla kt Woods AS LUFT/VANN VARMEPUMPE MED AKSIALVIFTER WRAQ R22

CVM 2 reguleringssystem

BRUKSANVISNING REGULATOR CVM 20

BRUKSANVISNING REGULATOR CVM 300

Comar Benelux NV Brugzavel 8 B-9690 Kluisbergen T +32 (0) F +32 (0)

Product Facts. Product code example

Water terminals SYSDUCT HP. Ductable fan coil unit

TUNNEL LIGHTING. LED Lighting Technology

På de følgende sidene vises tabellene med alle de viktigste parameterne, for de forskjellige modellene.

Clino Professional Ozone Generator ONY10-3 and ONY20-3 Instructions for assembly and use. Edition 3.

Eksamen KVT2002 Elenergi og automatiseringssystem/systemer. Programområde: Kulde- og varmepumpeteknikk. Nynorsk/Bokmål

230V 110V 25% (230V) 110V 110V 230V

BRUKSANVISNING REGULATOR CVM 3000

Tekniske data Vers Modell

Teknikk. Dette avsnittet gir enkle forklaringer påforskjellige typer av kuldeanlegg. Skissene og forklaringene måkun brukes som prinsippskisser.

Uninterruptible Power Supply On-line Double Conversion 7.5KVA - 600KVA

SHORE POWER CONVERTER LIST 2018

Driftsinstruks. Vannkjølt aggregat FWR. Vi håper de får stor glede av et Novema kulde produkt!

SEVERE DUTY GENERAL PURPOSE Three-Phase TEFC. Features that make a difference: Standard Features:

Driftsinstruks. Vannkjølt aggregat MEC. Vi håper de får stor glede av et Novema kulde produkt!

MAXI 1500/2000/3000/4000 HW STYREPANEL/CONTROL PANEL XL-20 side/page 4 STYREPANEL/CONTROL PANEL XL-50 side/page 5

Tekniske data Modell 10T 14M 14T 19T Varmekapasitet kw ,1 19,1

SERVICE / VEDLIKEHOLDSMANUAL

BRUKER INSTRUKS. For fan coil type FCX - U.

Driftsinstruks. Vannkjølt aggregat FWR R410a. Vi håper de får stor glede av et Novema kulde produkt!

Driftsinstruks. Dataromsaggregat type DAC. Vi håper de får stor glede av et Novema kulde produkt!

MCP-16RC, luftrenertårn

MSBCCL Series Asynchronous Three-Phase Brake Motors With Squirrel Cage Rotor Direct Current Brake

System. Vann vann isvannsaggregat

Prosjekt Nye tog November 2010

Aggregatnavnene JREF, TREF og NRG er overordnede navn, virkelig kode kommer av hva slags aggregat funksjon man skal ha. Noen eksempler på koder

ATC-L/BTC-L Dry Air Cooler

CONNECTION TERNINAL AND COMPONENTS

GRUNDFOS Pumper AS. Rune Sesaker. - Best på pumper

Subsea-Muligheter for virksomhet i den maritime klyngen. Utbygging og vedlikehold av subsea anlegg Prosjektleder : Torstein Vinterstø

Magna Track HS. Eksosavtrekk for utrykningsstasjoner med høyere frekvens/flere turer

BETJENING OG REGULERING AV ANLEGGET ISVANNSANLEGG

Splitt og monoblokk. for kjøl/frys. Katalog del 3.0 Januar IēēčĔđĉ.

DANGER. Carbon Monoxide. Using a generator indoors WILL KILL YOU IN MINUTES. Carbon Monoxide

BRUKER MANUAL NORSK VERSJON

Inverter. Varmepumpe N09 Heat pump N09 Ilmalämpöpumppu N09 ja asennustarvikkeet

Oversikt tele og datakjøling

Crocco Luftkjølte kondensatorer. Serie: CN, CL, CS.


Varme og kjøling for industri og bygg i over 100 år! Produktkatalog

Driftsinstruks. Viftekonvektor FCW. Vi håper de får stor glede av et Novema kulde produkt!

ZB5AV04 ( ) Signallampe rød for BA9s

ATS22C11S6 ( ) Mykstarter 110 A V

Complete tank expertise

Windlass Control Panel

RF Power Capacitors Class kV Discs with Moisture Protection

Deler Motorhode Skeetervac

Innhold

RF Power Capacitors Class1. 5kV Discs

DATAROMSAGGREGATER MED NED- OG OPPADRETTET LUFTSTRØM

Driftsinstruks. Viftekonvektor Omnia UL. Vi håper de får stor glede av et Novema kulde produkt!

Driftsinstruks. Dataromsaggregat med frikjølinjg DAS WXFO. Vi håper de får stor glede av et Novema kulde produkt!

TEKNISK SERVICE MANUAL. TAK / GULV MONTERT LUFTKJØLER Modeller EER / ENR / EN

Instruksjons manual Instruction manual

Service - Kontroll - Igangkjøring

HOBBYFISKERENS DRØM THE FISHERMANS DREAM

Service - Kontroll - Igangkjøring

Ved bedre separering av varme og kalde soner kan man tilføre kald luft med temperatur på 20 C og avtrekkstemperaturen kan økes til 30 C

KROPPEN LEDER STRØM. Sett en finger på hvert av kontaktpunktene på modellen. Da får du et lydsignal.

Driftsinstruks. Luftkjølt isvannsaggregat NS og aggregat med frikjøling NS-F.

BM 20 BLUE SEAL PLANETARY MIXER. BM20 PLANETARY MIXER Transmission Case. Planetary Shaft

Reservedeler for Weishaupt brenner WG5

Transkript:

Fla kt Woods AS LUFT/VANN ISVANNSAGGREGAT MED AKSIALVIFTER HRAT 0152 0604 R407c

eskrivelse aggregat UNIT DESCRIPTION Luft kjølt vannkjøleaggregat med aksial vifter laget for utendørs Air cooled liquid chiller with axial fans, suitable for outdoor installation. installasjon. Uniten er levert med ferdig antifreeze olje og R22/R407c. The unit is supplied with its full charge of antifreeze oil and R22 or Uniten er fabrikktestet slik at kun el og rør tilknytning må gjøres på R407C refrigerant charge. The unit is factory tested, so that only plassen water and electrical connections need to be made on site. Ramme Frame Ramme med paneler er laget i stål og behandlet for å kunne sikre Frame made of hot galvanized steel sheets painted with polyester beskyttelse mot vær og vind. powders. The external structure is made of Peraluman. The panels of the compressor enclosure are covered by a layer of high density acoustical lining. The self-standing structure containing the main components is designed to grant the maximum ease of access during service and maintenance operations. Kompressor Compressors To hermetiske scroll kompressorer opp til størrelse 0302 og 2 Two hermetic scroll compressors (up to size 0302), and two hermetic hermetiske stempel kompressorer for størrelse 0402-0502. Komplett reciprocating compressor (for sizes 0402-0502), complete with med bunnkasse varmer elektonisk overhetning med manuell reset. crankcase heater, electronic overheating protection with centralised Kompressorene har 2 polet elektrisk motor manual reset (thermal relay on size 0302). Compressors are equipped with two-pole electric motors. The compressors for sizes 0402-0502 are acoustically insulated by a special cap. Fordamper Evaporator AISI 316 plateveksler komplett med differnasetrykksbryter. Isolert for AISI 316 steel plate type complete of electrical resistors and å hindre kondens. differential pressostatic switch. The shell is insulated with a closed-cell neoprene anti-condensation lining. Kondensatorbatteri Condensing coils Varmeveksler laget av kobber rør og aluminium finner Heat exchanger coil made of copper pipes and aluminium fins. Ventilatori Fans Axial vifter med aliminiums blader. Axial fans with external rotor and die-cast aluminium blades. Seks polet motor med IP 54 beskyttelse plassert i en aerodynamisk Six pole electric motor complete with thermal protection and rated to ritkig utformet ramme med beskyttelsesgitter. IP54 protection. They are housed in an aerodynamic hood and Presostatstyring via av/på vifter. equipped with protection grilles. Kulde krets Refrigerant circuit Hver kuldekretser består av følgende komponenter, filter, se glass Each refrigerant circuit is complete with: dryer filter with replaceable med fuktighetsindikering, termisk ekspansjonsventil med utvendig core, sight glass equipped with humidity signal, externally equalised trykkutligning. Pressostater for høy og lav trykk thermal expansion valve, pressure switches for high and low pressure, liquid line shut-off valve, liquid line solenoid valve (on sizes 0302-0402 - 0502), muffler on compressor discharge line (for sizes 0402 and 0502). Elektrisk utstyr og kontroller Electrical board and control panel Electrical board and control panel are in compliance with EN Electrical board and control panel are in compliance with EN 604-1/IEC 4-1 norms, and complete with contactors for 604-1/IEC 4-1 norms, and complete with contactors for compressors, automatic circuit breakers for compressors and fans, compressors, automatic circuit breakers for compressors and fans, the auxiliary circuit is powered by a transformer and interlocked door the auxiliary circuit is powered by a transformer and interlocked door mains isolator is fitted as a standard. Contactors are of spring type mains isolator is fitted as a standard. Contactors are of spring type clamps to avoid cabling untighteness due to vibrations. clamps to avoid cabling untighteness due to vibrations. Controlled and regulated by a microprocessor, stepless variable fan Controlled and regulated by a microprocessor, stepless variable fan speed control by means of pressure transducer (the latter allows to speed control by means of pressure transducer (the latter allows to avoid unnecessary fans starts and grants a better control of the avoid unnecessary fans starts and grants a better control of the condensing pressure when working at low ambient temperature), condensing pressure when working at low ambient temperature), cumulative fault device signal, numbered cables, on/off switch, cumulative fault device signal, numbered cables, on/off switch, voltage supply 400V/3/50Hz +N + PE (+/-10%). The electrical panel, voltage supply 400V/3/50Hz +N + PE (+/-10%). The electrical panel, inside the supporting structure, is fitted with seal-tight double doors inside the supporting structure, is fitted with seal-tight double doors and is suitable for outdoor installation. and is suitable for outdoor installation. The electrical section follows the norms: CE 89/392/CEE (machine directive); 89/336/CEE (electromagnetic compatibility directive); 73/23/CEE (low tension directive). The electrical section follows the norms: CE 89/392/CEE (machine directive); 89/336/CEE (electromagnetic compatibility directive); 73/23/CEE (low tension directive). Modell HRAT kun kjøling. HRAT model only chiller. Versjon Version Standard versjon Standard version unit. A1

TEKNISKE DATA Kapasitet Kulde kapasitet Effekt forbruk Totalt effekt forbruk Fordamper vann mengde Fordamper trykk fall CVM mikroprosessor Vifter Antall vifter Luftmengde Kuldemedie R407c STØRRELSE 0152 0182 02 0252 0302 0402 0502 [kw] 36 43 51 63 75 89 110 [kw] 14 16 18 23 29 36 44 [kw] 14 17 19 24 31 37 46 [m³/h] 6 7 9 11 19 [k] 30 30 32 31 40 40 41 2 2 2 2 2 2 2 [n] 4 4 6 6 8 8 10 [m³/h] 3,8 3,7 5,7 5,5 7,7 7,5 9,6 Kompressor Antall kompressorer Antall kretser Kapasitets trinn Fylling mengder Kuldemedie Olje [n] 2 2 2 2 2 2 2 [n] 2 2 2 2 2 2 2 STD+OPT [n] 2 2 2 2 2 2 2 [kg] 12 14 18 22 27 [kg] 8 8 8 8 13 13 13 Drifts vekt [kg] 510 540 590 640 710 800 930 Lyd effekt nivå Lyd trykk nivå (1) [d(a)] 78 78 79 80 81 82 83 [d(a)] 63 63 63 64 65 66 67 (1) Pressione sonora misurata ad 1 m in campo aperto Lyd trykk målt på avtsand 1 meter i fritt felt Data oppgittt ved Isvann Utetemperatur 12/7 [ C] 35 [ C] 1

TEKNISKE DATA Kapasitet Kulde kapasitet Effekt forbruk Totalt effekt forbruk Fordamper vann mengde Fordamper trykk fall CVM mikroprosessor Kuldemedie R407c 0524 0604 [kw] 133 155 [kw] 48 56 [kw] 52 61 [m³/h] 23 27 [k] 37 38 PICO PICO STØRRELSE Vifter Antall vifter Luftmengde Kompressor Antall kompressorer Antall kretser Kapasitets trinn Fylling mengder Kuldemedie Olje [n] 2 2 [m³/h] 11,6 11,3 [n] 4 4 [n] 2 2 STD+OPT [n] 4 4 [kg] 26 29 [kg] 16 26 Drifts vekt [kg] 1400 1490 Lyd effekt nivå Lyd trykk nivå (1) [d(a)] 92 92 [d(a)] 76 76 (1) Pressione sonora misurata ad 1 m in campo aperto Lyd trykk målt på avtsand 1 meter i fritt felt Data oppgittt ved Isvann Utetemperatur 12/7 [ C] 35 [ C] 2

KULDEKAPASITET Kuldemedie R407c COOLING CAPACITY Modell 0152 Modell 0182 Modell 02 Modell 0252 Modell 0302 Pf 42 43 45 Qev 7 7 8 dpev 41 45 49 Pt 47 49 51 10 10 10 8 8 9 53 57 62 Pf 50 52 54 Qev 9 9 9 dpev 41 44 48 Pt 57 59 61 11 12 12 10 10 11 52 56 61 Pf 59 61 64 Qev 10 11 11 dpev 43 46 50 Pt 66 69 72 13 13 13 11 12 12 55 59 64 Pf 73 76 79 Qev 12 13 14 dpev 42 46 50 Pt 82 85 89 16 16 16 14 15 15 54 59 63 Pf 86 90 94 Qev 15 16 16 dpev 53 58 63 Pt 98 102 105 22 22 23 17 18 18 68 74 79 Pf 41 43 45 Qev 7 7 8 dpev 40 43 47 46 48 50 10 10 10 8 8 9 51 55 60 Pf 49 51 53 Qev 8 9 9 dpev 39 43 46 56 58 60 12 12 12 10 10 10 50 55 59 Pf 58 60 63 Qev 10 10 11 dpev 41 45 49 65 68 71 13 13 13 11 12 12 53 57 62 Pf 71 74 78 Qev 12 13 13 dpev 41 44 48 81 84 87 17 17 17 14 14 15 52 57 61 Pf 85 89 92 Qev 15 15 16 dpev 51 56 61 96 100 104 23 23 24 17 17 18 66 71 77 Pf 40 42 44 Qev 7 7 8 dpev 38 42 45 24 Pt 46 47 49 11 11 11 8 8 8 49 53 58 Pf 48 50 52 Qev 8 9 9 dpev 38 41 45 24 Pt 55 57 59 12 13 13 10 49 53 57 Pf 57 59 62 Qev 10 10 11 dpev 40 43 47 24 Pt 64 67 69 14 14 14 11 12 12 51 55 60 Pf 70 73 76 Qev 12 13 13 dpev 39 43 47 24 Pt 79 83 86 18 18 18 14 14 15 51 55 59 Pf 83 87 91 Qev 14 15 16 dpev 50 54 59 24 Pt 94 98 102 24 24 25 16 17 18 64 69 74 Pf 40 42 43 Qev 7 7 7 dpev 38 41 45 Pf 48 50 52 Qev 8 9 9 dpev 37 40 44 Pf 56 59 61 Qev 10 10 11 dpev 39 43 46 Pf 69 72 76 Qev 12 12 13 dpev 39 42 46 Pf 83 86 90 Qev 14 15 16 dpev 49 53 58 45 47 49 11 11 11 8 8 8 48 52 57 54 56 58 13 13 13 10 48 52 56 64 66 69 14 14 14 11 11 12 50 55 59 79 82 85 18 18 18 14 14 15 50 54 58 94 97 101 24 25 25 16 17 17 62 68 73 Pf 39 41 43 Qev 7 7 7 dpev 36 39 43 Pf 47 49 51 Qev 8 8 9 dpev 36 39 42 Pf 55 58 60 Qev 10 dpev 38 41 45 Pf 68 71 74 Qev 12 12 13 dpev 37 41 44 Pf 81 85 88 Qev 14 15 15 dpev 47 51 56 44 46 48 11 11 12 8 8 8 47 50 54 53 55 57 13 14 14 10 46 50 54 63 65 68 15 15 15 11 11 12 49 53 57 77 80 83 19 19 19 13 14 14 48 52 56 92 96 99 25 26 26 16 16 17 60 65 70 Pf 38 40 41 Qev 7 7 7 dpev 34 37 40 Pf 45 47 49 Qev 8 8 9 dpev 34 37 40 Pf 53 56 58 Qev 10 dpev 35 39 42 Pf 66 69 72 Qev 11 12 12 dpev 35 38 42 Pf 79 82 86 Qev 14 14 15 dpev 44 48 52 43 45 46 12 12 12 7 8 8 44 48 51 51 54 56 14 15 15 9 43 47 51 61 63 66 16 16 16 10 11 11 46 50 54 75 78 81 21 13 13 14 45 49 53 89 93 96 27 27 28 15 16 17 57 61 66 Tev [ C] Fordamper utgående vann [ C] condenser water in/out Pf [kw] Kulde kapasitet Pt [kw] Varme kapasitet [kw] Kompressorer effekt forbruk Qev [m³/h] Fordamper vann mengde dpev [k] Fordamper trykk fall [m³/h] Kondensator vann mengde [k] Kondensator trykk fall C1

KULDEKAPASITET Kuldemedie R407c COOLING CAPACITY Modell 0402 Modell 0502 Modell 0524 Modell 0604 Pf 109 114 119 Qev 19 dpev 60 65 71 Pt 124 129 134 32 32 33 21 22 23 77 84 91 Pf 133 139 145 Qev 23 24 25 dpev 61 66 72 Pt 151 157 163 39 40 41 26 27 28 78 84 91 Pf 153 160 167 Qev 26 27 29 dpev 49 54 59 Pt 173 180 187 36 36 37 30 31 32 64 69 75 Pf 178 186 194 Qev 31 32 33 dpev 50 55 59 Pt 2 210 218 41 42 43 35 36 38 64 70 75 Pf 106 111 116 Qev 18 19 dpev 57 62 68 121 126 131 32 33 34 21 22 23 74 80 87 Pf 130 136 142 Qev 22 23 24 dpev 58 63 69 148 153 159 40 41 42 25 26 27 74 80 87 Pf 151 157 164 Qev 26 27 28 dpev 48 52 57 171 178 185 37 38 38 29 31 32 62 67 72 Pf 175 183 191 Qev 30 32 33 dpev 48 53 57 199 7 215 43 44 45 34 36 37 62 67 73 Pf 103 108 113 Qev 18 19 19 dpev 54 59 65 24 Pt 118 123 128 33 34 35 21 22 70 76 83 Pf 127 133 138 Qev 22 23 24 dpev 55 60 65 24 Pt 144 150 156 40 42 43 25 26 27 71 77 83 Pf 148 155 161 Qev 26 27 28 dpev 46 51 55 24 Pt 168 175 182 38 39 40 29 30 31 60 65 70 Pf 172 180 188 Qev 30 31 32 dpev 47 51 56 24 Pt 195 3 211 45 46 47 34 35 36 60 65 70 Pf 102 107 112 Qev 18 18 19 dpev 53 58 63 Pf 125 131 137 Qev 22 23 24 dpev 54 59 64 Pf 147 154 160 Qev 25 26 28 dpev 46 50 54 Pf 171 178 186 Qev 29 31 32 dpev 46 50 55 117 121 126 33 34 35 21 22 69 75 81 142 148 154 41 42 43 25 26 27 69 75 81 167 173 180 39 40 41 29 30 31 59 64 69 194 1 9 46 47 48 33 35 36 59 64 69 Pf 100 104 109 Qev 17 18 19 dpev 50 55 60 Pf 122 128 133 Qev 21 22 23 dpev 51 56 61 Pf 144 151 157 Qev 25 26 27 dpev 44 48 52 Pf 168 175 183 Qev 29 30 31 dpev 44 48 53 114 119 123 34 35 36 21 65 71 77 139 144 150 42 43 44 24 25 26 66 71 77 164 170 177 41 41 42 28 29 31 57 61 66 190 198 5 48 49 50 33 34 35 57 62 67 Pf 96 100 105 Qev 16 17 18 dpev 46 51 55 Pf 117 123 128 Qev 21 22 dpev 47 51 56 Pf 140 146 153 Qev 24 25 26 dpev 42 45 49 Pf 163 170 178 Qev 28 29 31 dpev 42 46 50 109 114 119 34 36 37 19 60 66 71 134 139 144 43 44 45 23 24 25 61 66 71 159 165 172 43 44 45 27 29 30 54 58 63 185 192 0 51 52 53 32 33 34 54 58 63 Tev [ C] Fordamper utgående vann [ C] condenser water in/out Pf [kw] Kulde kapasitet Pt [kw] Varme kapasitet [kw] Kompressorer effekt forbruk Qev [m³/h] Fordamper vann mengde dpev [k] Fordamper trykk fall [m³/h] Kondensator vann mengde [k] Kondensator trykk fall C2

LYD TRYKK VED FULL ELASTNING Kuldemedie R407c - Oktav bånd [Hz] Lyd trykk d(a) / Avstand [m] 63 125 250 500 1000 00 4000 8000 Total Modell -Lyd trykk nivå [d] d(a) 5 10 15 0152 73 63 62 61 58 54 48 50 63 0182 73 64 62 61 58 54 47 51 63 02 75 65 62 61 58 54 47 51 63 0252 76 65 63 62 58 54 48 51 64 0302 78 66 64 61 61 57 51 47 65 0402 80 66 63 61 60 59 54 43 66 0502 80 67 63 64 61 59 53 44 67 0524 73 72 75 71 70 70 63 58 76 0604 73 72 75 71 70 70 63 58 76 Driftsbetingelser Fordamper (inn/ut) 12/7 [ C Utetemperatur 35 [ C] Test punkt Ved 1 meter fra aggregat og i 1 meters høyde over ramme. Lyd trykk refererer seg til avstand og målt i åpent felt faktor Q = 1 hvis Q=2 (en reflekterende flate) legg til 3 d(a) hvis Q=4 to reflekterende flate) legg til 6 d(a) hvis Q=8 (tre reflekterende flate) legg til 9 d(a) emerkning: For aggregat som er montert over gulv. Må gulvet taes med som en reflekterende flate. Kommentar: Lyd trykks nivå i avstand må bare sees på som veieldende. Da tallene er regnet frem matematisk. H1

Din totalleverandør av kulde- og ventilasjonsprodukter Produkter for godt inneklima året rundt. Ventilasjonsaggregater Isvannsmaskiner Luftfordelingsutstyr Air-conditioning Luftvarmere Tørrkjølere Spjeld Fan-coils Vifter Kjøletårn efuktere Dx-maskiner Varmegjenvinnere Varmepumper Varme- og kjølebatterier Dataromkjøling AS HOVEDKONTOR AVD. TROMSØ AVD. TRONDHEIM AVD. ERGEN AVD. STAVANGER Postboks 114, Postboks 2134, Fossegrenda 30, Postboks 64, Postboks 2138 N-03 Lillestrøm 9267 Tromsø 7038 Trondheim 5848 ergen 4394 Sandnes Tlf.: 63 81 14 00 Tlf.: 77 61 64 00 Tlf.: 73 84 45 60 Tlf.: 55 94 11 Tlf.: 51 67 33 Fax: 63 81 98 66 Fax: 77 65 02 70 Fax: 73 96 44 88 Fax: 55 34 17 54 Fax: 51 67 33 01