FibreCore UWIC Enkelarmert sjøkabel

Like dokumenter
FibreCore ADSS Light

FibreCore A-DQ(ZN)2Y Mikrokabel

FibreCore SC Mikro Blåsekabel 250µm

FibreCore SC Mikro Blåsekabel 200µm

FibreCore SC Mikro Blåsekabel 200µm

FibreCore QXXE Mikro blåsekabel

FibreCore Kanalkabel QXXE light

FibreCore QXXI-I/O-W MicroSheath

FibreCore Inne/ute kabel AXXI-I/O-W

FibreCore Inne/ute kabel AXAI-I/O-W

PRODUCT MODEL 1 FIBER PRODUCT FAMILY SUBSCRIBER CABLES FEATURES SPECIFICATIONS

Bergen Cabling DNV GL godkjent LAN Hybrid kabel S/FTP Cat OS2 singel modus fibre

SPECIFICATIONS. LSZH jacket, blue, orange, green, brown, with Corning Clear- Curve LBL, G657

QXAI Micro Sheath B-VE R- NO GG- DS

AXXI I/O-W FRLSZH -A V -RE -1-NO GG S D

QXAI Micro Sheath -B V -RE 25-1-NO GG S D

AXAI I/O-W FRLSZH -D V -RE -1-NO GG S D

PRODUCT MODEL PRODUCT FAMILY FEATURES SPECIFICATIONS

1xN og 2xN PLC Splitter

Rotagrip Ltd Tel 0044 (0) Website FOR VPC-TYPE. Speed Max R.P.M. Speed Max R.P.M.

Kabel QXXE light C-VE R- NO GG- DS

Metal Oxide Varistor:TVA Series

Cylindrical roller bearings

Fiberkabel Mai Nexans Produktsortiment Fiberkabel

Monteringsprosedyre for Soundstop - lydmatte

Product Change Notice

Steatite Interlocking Beads. Steatite Band heater (Regular) Steatite Band Heater (Small) Steatite Band Heater (Large)

TUNNEL LIGHTING. LED Lighting Technology

Product Facts. Product code example

Kabel QXXE slim -E V -RE -1-NO GG S D

Data Sheet for Joysticks

Kabel pre-terminert Singelmodus

Data Sheet for Joysticks

GIMOTA AG. Assembly Instructions Dataconnectors D-SUB. Datenstecker Katalog Gimota AG 04/14 3

Data Sheet for Joysticks

Kabel pre-terminert Singelmodus Break-out

RF Power Capacitors Class kV Discs with Moisture Protection

Data Sheet for Joysticks

Data Sheet for Joysticks

1. med støvhetter (blind deksel) i alle hull, (se bilde øverst på siden) og et kveilekryss.

Neural Network. Sensors Sorter

Abbonentsnor Abbonentkabel

Smart High-Side Power Switch BTS730

RF Power Capacitors Class , 20 & 30 mm Barrel Transmitting Types

Kabel pre-terminert SM Til patch panel GP15/GP20

EGENSKAPER ANVENDELSE. Technical data sheet ESCR - KONSTRUKSJONSSKRUE TIL TRE

Edge Of Dock Leveler. Size: Widths 66, 72, 78, 84. Lengths 15, 17 Lips. Capacities: 20,000 25,000 30,000 35,000 NEVERLIFT NL

Cylindrical roller bearings

Recessed high tech, linear downlight - The result of lengthy research to produce a product with a high level of visual comfort.

Data Sheet for Joysticks

GIMOTA AG. Assembly Instructions Dataconnectors DIN F. Datenstecker Katalog Gimota AG 04/14

Fitting instruction. devi-pipeheat / devi-flexheat Assembly between cold tail and selflimiting. Montering av tilledning på selvbegrensende varmekabel

ELSEMA 1, 2, 4-Channel 27MHz Transmitter FMT312E, FMT31202E, FMT31204E

Generelle krav i nettet

STILLAS - STANDARD FORSLAG FRA SEF TIL NY STILLAS - STANDARD

MPS Splitter Modulært splitter System

Independent Inspection

1. med støvhetter (blind deksel) i alle hull, (se bilde øverst på siden) og et kveilekryss.

PSi Apollo. Technical Presentation

ST8A-EM 14 W/ mm

Zone Diameter Riper Defekter A: Kjerne 0 µm 65 µm 1) Ingen Ubegrenset 2 µm

PrO-ASTM Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Oil testing. Petroleum testing, ASTM methods

BORD inspirasjon fra utvalgte leverandører

SubstiTUBE T5 High Output

RF Power Capacitors Class1 5kV Discs

Hydal Aluminium legeringer Hydal Aluminium alloys

Bytte til split Collin Lanyard RSL. Obligatorisk - alle rigger skal ha dette montert ved hopping etter

RF Power Capacitors Class1

Den brysomme veien til kvalitetsbolter..

Statens vegvesen. Testene tilfredsstiller kravene til styrkeklasse T3 med en målt arbeidsbredden på 0,7m.

Comar Benelux NV Brugzavel 8 B-9690 Kluisbergen T +32 (0) F +32 (0)

DC/AC inverters DC/AC invertere

Den europeiske byggenæringen blir digital. hva skjer i Europa? Steen Sunesen Oslo,

Emnenavn: Oppgavesettet består av 3 oppgaver. Alle spørsmålene teller likt.

RF Power Capacitors Class1. 5kV Discs

RF Power Capacitors Class1 : 10kV Discs

Re-board for ulike kategorier:

Konstruksjonsstål for arktiske forhold krav til sveisbarhet og egenskaper. Norsk Korrosjonsteknisk forening Mons Hauge, Statoil

PIPESTEC INDUSTRIAL GROUP LIMITED

OTC USE IN NORWAY FOR PARACETAMOL, ATC-CODE: N02BE01

HØGSKOLEN I NARVIK - SIVILINGENIØRUTDANNINGEN

(see table on right) 1,500,001 to 3,000, ,001pa to 250,000pa

Hydal Aluminium legeringer Hydal Aluminium alloys

Hydal Aluminium legeringer Hydal Aluminium alloys

AvtaleGiro beskrivelse av feilmeldinger for oppdrag og transaksjoner kvitteringsliste L00202 levert i CSV fil

SVM and Complementary Slackness

Finansieringsmuligheter i EU - noen eksempler

TriCOM XL / L. Energy. Endurance. Performance.

En praktisk anvendelse av ITIL rammeverket

LANmark-OF Patch Cords

Statens vegvesen. Rekkverket med føringsskinne av type A er i utgangspunktet samme egenskaper som det som var fullskalatestet, type B.

Statens vegvesen. Rekkverket med føringsskinne av type A er i utgangspunktet samme egenskaper som det som var fullskalatestet, type B.

YTELSESERKLÆRING. HECO-DoP_ETA_15/0784_MMS-plus_1804_NO

Statens vegvesen. Fra VSI test senter: testrapportnummer KIR14003 datert TB32 test av

Transkript:

FibreCore UWIC Enkelarmert sjøkabel

FibreCore UWIC er en sjøkabel med ett lag med galvanisert ståltrådarmering og med ytre kappe av slitesterk polyetylen. Kabelen leveres med 12 til 288 G.652D fibre som er merket i henhold til Telenor farge kode. Kabelen egner seg for forlegning i grunne innsjøer, vassdrag eller i grunne farvann langs kysten. 1. GENERAL 1.1 Scope The listed specifications covers the design requirements and performance standard for the supply of optical fiber cable in the industry. It also includes this premium designed cable with optical, mechanical and geometrical characteristics. Cable marking FibreCore-xxx G.652D-FSwUW-S1 Application Under water installation cable xxx: Fiber count 1.2 Cable Description The cable possesses high tensile strength and flexibility in a compact cable size. At the same time, it provides excellent optical transmission and physical performance. 1.3 Quality Excellent quality control is achieved through intense in-house quality check and stringent audit acceptance by ISO 9001. 1.4 Reliability Initial and periodic product qualification tests for performance and durability are performed rigorously to ensure product reliability. 1.5 Reference The cable offered are designed, manufactured and tested according international standards as follows: IEC 60793-1 IEC 60793-2 IEC 60794-3-30 ITU-T G.650 ITU-T G.652 Optical fiber Part 1: Generic specifications Optical fiber part2: Product specifications Optical fiber cables: Part 3-30, outdoor cables- family specification for lake and river crossings Definition and test methods for the relevant parameters of single-mode fibers Characteristics of a single-mode optical fiber and cable 2. OPTICAL FIBER The optical fiber is made of high pure silica and germanium doped silica. UV curable acrylate material is applied over fiber cladding as optical fiber fiber primary protective coating. The detail data of optical fiber performance are shown in the following table. ITU-T G652 fiber uses special spun device to successfully control the value of PMD to ensure stability during cabling. DS-MG-00034-1-NO-Rev-A Metric Industrial AS reserverer seg retten til å foreta endringer i spesifikasjonen uten videre forvarsel side 1 av 5

G.652D Fiber Category Optical Specifications Specifications Description Before cabling After cabling Attenuation @ 1310 nm 0,34 db/km 0,36 db/km Attenuation @ 1550 nm 0,20 db/km 0,22 db/km Zero Dispersion Wavelength 1300~1324 nm Zero Dispersion Slope 0,092ps/nm 2 -km PMD Max. Value 0,2 ps/ km Cable Cutoff Wavelenght (λ 1260 nm Macro bending loss (100 turns ø50 mm) @ 1550 nm 0,05 db (100 turns ø50 mm) @ 1625 nm 0,10 db MDF (Mode Field Diameter) @ 1310 nm 9,2 ± 1µm Cladding Diameter 125 ± 1µm Dimensional Core/clad concentricity error 0,6µm Specifications Cladding non-circularity 1,0% Mechanical Specifications Proof stress 0,69Gpa 3. CABLE STRUCTURE 3.1 Cable type Bildet er kun for referanse Construction: 1. Outer sheath (HDPE) 2. Galvanized steel wire armor 3. Loose tube, fiber and jelly 4. Inner sheath (HDPE) 5. Central strength member (Coated FRP) 6. Thixotropic jelly 7. Water blocking tape 8. Wrap tape 9. Ripcord x2 Technical Characteristics: The unique extruding technology provides the fibers in the tube with good flexibility and bending endurance The unique fiber excess length control method provides the cable with excellent mechanical and environmental properties Multiple water blocking material fillings provides dual water blocking function DS-MG-00034-1-NO-Rev-A Metric Industrial AS reserverer seg retten til å foreta endringer i spesifikasjonen uten videre forvarsel side 2 av 5

Dimension and Properties Fiber count 12 24 48 96 144 192 240 288 No. of loose tube/filler layer 1 1/5 2/4 4/2 8/0 12/0 6/0 9/0 9/0 No. of loose tube/filler layer 2 - - - - - 10/2 11/4 15/0 Fiber no. per tube 12 Cable OD, nominell (mm) 14,5 14,5 14,5 15,7 18,9 20,0 21,2 21,2 Cable weight, nominell (kg/km) 400 403 405 445 630 815 870 875 Operation temp. range ( C) -40 ~+70 Installation temp. range ( C) -20 ~+70 Transport/storage temp. range ( C) -40 ~+70 Max.tensile load (N) 5000 Crush resistance (N/10cm) Short term: 5000, Long term: 2000 Minimum installation bending radius Minimum operational bending radius 30 x OD 15 x OD COLOR CODE SCHEME Color code fiber 1 2 Hvit Rød 3 Gul 4 Grønn 5 Blå 6 Grå 7 Brun 8 Sort 9 Violett 10 11 12 Color code tube layer 1 (inner layer) 1 2 3 4 Hvit Rød Gul Grønn 5 Blå 6 Grå 7 Brun 8 Sort 9 Violett 10 11 12 Color code tube layer 2 (outer layer) 1 Hvit 2 Rød 3 Gul 4 Grønn 5 Blå 6 Grå 7 Brun 8 Sort 9 Violett 10 11 12 13 14 15 Other color code scheme are available on request. 4. TEST REQUIREMENT The cable is in accordance with applicable standard of cable and requirement of customer. The following test items are carried out according to corresponding reference. Mode field diameter IEC 60793-1-45 Core/clad concentricity IEC 60793-1-20 Cladding diameter IEC 60793-1-20 Cladding non-circularity IEC 60793-1-20 Attenuation coefficient IEC 60793-1-40 Chromatic dispersion IEC 60793-1-42 Cable cut-off wavelength IEC 60793-1-44 DS-MG-00034-1-NO-Rev-A Metric Industrial AS reserverer seg retten til å foreta endringer i spesifikasjonen uten videre forvarsel side 3 av 5

TEST LIST 4.1 Tension Loading Test Sample length Load Duration time IEC 60794-1-2 E1 No less than 50 mtr. Max. Tension load 10 min. Fiber strain 0,33% Additional attenuation 0,1dB No damage to outer jacket nor inner elements 4.2 Crush/Compression Test Load Duration time IEC 60794-1-2 E3 Crush load 5 min. Test number 3 Additional attenuation 0,1dB No damage to outer jacket nor inner elements 4.3 Impact Resistance Test Impact energy Radius IEC 60794-1-2 E4 10J 300mm Impact points 3 Impact numbers 1 Additional attenuation 0,1dB No damage to outer jacket nor inner elements 4.4 Temperature Cycling Test Impact energy Radius IEC 60794-1-2 F1 +20 C ->-40 C ->+70 C ->-40 C ->+70 C ->+20 C 12 hrs Impact points 2 After test, attenuation variation for reference value (the attenuation to be measured before test at +20±3 C) 0,10dB/km at 1550 nm 4.5 Water Penetration Test Height of water column Sample length Test time IEC 60794-1-2 F5B 1 mtr. 3 mtr. 24 hrs No water leakage from the opposite of the cable core DS-MG-00034-1-NO-Rev-A Metric Industrial AS reserverer seg retten til å foreta endringer i spesifikasjonen uten videre forvarsel side 4 av 5

4.6 Drip Test Sample length Temperature Duration IEC 60794-1-2 E14 0,3 mtr. 70 C 24 hrs No filling compound shall drip from the tubes 5. PACKAGING AND DRUM 5.1 The cables are coiled on Iron-wooden drum. During transportation, the correct tools should be used to avoid damaging the package and to handle with ease. Cables should be protected from moisture, kept away from high temperature and fire sparks. It should be protected from over bending and crushing as well as from mechanical stress and damage. 5.2 The color of cable marking is white (The printing shall be carried out at interval of 1 meter on the outer sheath of the cable) The inner end of the cable is then sealed with heat shrinkable end cap to prevent ingress of water and is made available for testing. The outer end of the cable is equipped with heat shrinkable end cap. Outer sheath marking legend can be changed upon user s request 5.3 Outdoor cable packing. Iron wooden drum. Strong wooden batten protection. ORDERING INFORMATION Elnr MI art. Nr. Beskrivelse 10 009 60 G12-9/125 B1.D UWIC 1S G12 FibreCore UWIC enkelarmert sjøkabel, G.652D 10 009 61 G24-9/125 B1.D UWIC 1S G24 FibreCore UWIC enkelarmert sjøkabel, G.652D 10 009 62 G48-9/125 B1.D UWIC 1S G48 FibreCore UWIC enkelarmert sjøkabel, G.652D 10 009 63 G96-9/125 B1.D UWIC 1S G96 FibreCore UWIC enkelarmert sjøkabel, G.652D 10 009 64 G144-9/125 B1.D UWIC 1S G144 FibreCore UWIC enkelarmert sjøkabel, G.652D 10 009 65 G192-9/125 B1.D UWIC 1S G192 FibreCore UWIC enkelarmert sjøkabel, G.652D 10 009 66 G240-9/125 B1.D UWIC 1S G240 FibreCore UWIC enkelarmert sjøkabel, G.652D 10 009 67 G288-9/125 B1.D UWIC 1S G288 FibreCore UWIC enkelarmert sjøkabel, G.652D DS-MG-00034-1-NO-Rev-A Metric Industrial AS reserverer seg retten til å foreta endringer i spesifikasjonen uten videre forvarsel side 5 av 5