SECTION 55 VALVES Diesel Fuel Check Valves CKV/PRV Series

Like dokumenter
Product Facts. Product code example

REMOVE CONTENTS FROM BOX. VERIFY ALL PARTS ARE PRESENT READ INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION

Justeringsanvisninger finnes på de to siste sidene.

Exercise 1: Phase Splitter DC Operation

Start Here USB *CC * *CC * USB USB

Data Sheet for Joysticks

SHORE POWER CONVERTER LIST 2018

Slope-Intercept Formula

Unit Relational Algebra 1 1. Relational Algebra 1. Unit 3.3

Information search for the research protocol in IIC/IID

Data Sheet for Joysticks

Cylindrical roller bearings

Data Sheet for Joysticks

ELSEMA 1, 2, 4-Channel 27MHz Transmitter FMT312E, FMT31202E, FMT31204E

Windlass Control Panel

Eksamen KVT2002 Elenergi og automatiseringssystem/systemer. Programområde: Kulde- og varmepumpeteknikk. Nynorsk/Bokmål

AVS MAGMA SOLENOID VALVES

Hvordan føre reiseregninger i Unit4 Business World Forfatter:

RF Power Capacitors Class1. 5kV Discs

RF Power Capacitors Class kV Discs with Moisture Protection

The regulation requires that everyone at NTNU shall have fire drills and fire prevention courses.

ALUMINUM TWIN STACK PORTABLE AIR COMPRESSOR OL50135AL OPERATOR S MANUAL

KROPPEN LEDER STRØM. Sett en finger på hvert av kontaktpunktene på modellen. Da får du et lydsignal.

Data Sheet for Joysticks

TUNNEL LIGHTING. LED Lighting Technology

RF Power Capacitors Class , 20 & 30 mm Barrel Transmitting Types

Dagens tema: Eksempel Klisjéer (mønstre) Tommelfingerregler

NEOREST Hybrid (Toilet bowl) NEOREST Hybrid. Installation manual. Safety Cautions Precaution before installation. Included parts.

Complete tank expertise

SERVICE BULLETINE

DANGER. Carbon Monoxide. Using a generator indoors WILL KILL YOU IN MINUTES. Carbon Monoxide

INSTALLATION GUIDE FTR Cargo Rack Regular Ford Transit 130" Wheelbase ( Aluminum )

Cylindrical roller bearings

INSTALLATION GUIDE FTR Cargo Rack Regular Ford Transit 130" Wheelbase ( Aluminum )

Data Sheet for Joysticks

AC10. Brukermanual Brugsanvisning Bruksanvisning User Manual. Spenningsdetektor Voltage Detector. English Norsk

MCP-16RC, luftrenertårn

MID-TERM EXAM TDT4258 MICROCONTROLLER SYSTEM DESIGN. Wednesday 3 th Mars Time:

5 E Lesson: Solving Monohybrid Punnett Squares with Coding

Institutt for biovitenskap

NÅR FAGKUNNSKAP & KOMPETANSE TELLER BRUKERMANUAL ELIT AC10 SPENNINGSDETEKTOR USER MANUAL ELIT AC10 VOLTAGE DETECTOR. English Norsk

Replacing the carbon brushes

DC/AC inverters DC/AC invertere

Comar Benelux NV Brugzavel 8 B-9690 Kluisbergen T +32 (0) F +32 (0)

SEVERE DUTY GENERAL PURPOSE Three-Phase TEFC. Features that make a difference: Standard Features:

Instruksjons manual Instruction manual

PSi Apollo. Technical Presentation

Perpetuum (im)mobile

Smart High-Side Power Switch BTS730

Water terminals SYSDUCT HP. Ductable fan coil unit

Midnight BBQ Light USER MANUAL

CTGA Meeting February 2, 2012

2018 ANNUAL SPONSORSHIP OPPORTUNITIES

Replacing the tube and/or tyre of a drive wheel, indoor/outdoor

Data Sheet for Joysticks

KAMPANJE APK : APK-5: Skifte pakninger mellom turbo og CCDPF

Compello Fakturagodkjenning Versjon 10 Software as a service. Tilgang til ny modulen Regnskapsføring

Neural Network. Sensors Sorter

SafeRing / SafePlus Retrofit of auxiliary switch S9 for fuse blown indication F module

OMT Technical Information. Versions OMT. Versions

Compello Fakturagodkjenning Versjon 10.5 As a Service. Tilgang til Compello Desktop - Regnskapsføring og Dokument import

Robertson S35 NFU Steering Lever

RF Power Capacitors Class1 5kV Discs

TriCOM XL / L. Energy. Endurance. Performance.

RF Power Capacitors Class kV Discs

1 BANESTRØMFORSYNING TOGVARMEANLEGG KONTAKTLEDNINGSANLEGG... 5

MONTASJEBESKRIVELSE INSTALLATION GUIDE

HONSEL process monitoring

Edge Of Dock Leveler. Size: Widths 66, 72, 78, 84. Lengths 15, 17 Lips. Capacities: 20,000 25,000 30,000 35,000 NEVERLIFT NL

Data Sheet for Joysticks

Elektronisk innlevering/electronic solution for submission:

Oppgave. føden)? i tråd med

25 Monate Garantiebedingungen 25 mois conditions de garantie 25 months warranty conditions

Duke Energy Seminar September 3 5, 2008 Concord, NC

Godkjenning av hydrogen som drivstoff på skip

KAMPANJE APK : APK-8: Bytte bakaksel bolter

Sitronelement. Materiell: Sitroner Galvaniserte spiker Blank kobbertråd. Press inn i sitronen en galvanisert spiker og en kobbertråd.

Fitting instruction. devi-pipeheat / devi-flexheat Assembly between cold tail and selflimiting. Montering av tilledning på selvbegrensende varmekabel

C C A Stainless Steel A F593/F594 Stuffing Box A. Stuffing Box O-Ring/gasket C/F594. Grade Grade

2A September 23, 2005 SPECIAL SECTION TO IN BUSINESS LAS VEGAS

RF Power Capacitors Class1 : 10kV Discs

Trådløsnett med Windows XP. Wireless network with Windows XP

RF Power Capacitors Class kV Discs with Moisture Protection

UNIVERSITETET I OSLO

Bytte til split Collin Lanyard RSL. Obligatorisk - alle rigger skal ha dette montert ved hopping etter

#89853 Command Center

Monteringsanvisning Installation manual Taksokkel for LHH og CareLite Ceiling mount for LHH and CareLite

FirstEnergy s Ohio Utilities. Energy Efficiency Programs for Business

Andrew Gendreau, Olga Rosenbaum, Anthony Taylor, Kenneth Wong, Karl Dusen

PTM Valve Manifolds with Eltorque Actuators

Rotagrip Ltd Tel 0044 (0) Website FOR VPC-TYPE. Speed Max R.P.M. Speed Max R.P.M.

VEKSELVENTILKASSER ND50-ND150, NT10 X-over Valve Manifolds ND50-ND150, PN10

230V 110V 25% (230V) 110V 110V 230V

- Vennlig hilsen gründerne bak retyre

Bruk av ALARP analyse for beslutningstaking på behovet for sikkerhetssystemer / barrierer

Windows Server 2008 Hyper-V, Windows Server 2008 Server Core Installation Notes

JBV DSB godkjenninger

bondura dual 36 Ø50mm - Ø200mm assembly & inspection manual art rev A

bondura Multi Tool 200 Hydraulic Ø200mm - Ø320mm user manual - for disassembly

Transkript:

SECTION 55 VALVES 7867 Diesel Fuel Check Valves CKV/PRV Series............................................... 273 99026 Diesel-Fuel Shutoff Valves SV Series..................................................... 275 94134 Electromechanical Fuel Shutoff Valves M25 and M50 Series.................................. 279 94129 Pneumatic Valves for Fuel Gas Shutoff Models M2582-P and M5180-P........................................................... 283 95145 Pulsation Dampener PD8100 Series..................................................... 285

THIS PAGE INTENTIONALLY LEFT BLANK. TABLE OF CONTENTS

Diesel Fuel Check Valves - 273-7867 Revised 04-01-10 Section 55 Features esel Engine Shutdown Systems Murphy offers two types of diesel fuel line valves: check valves and pressure relief valves. The CKV series check valves are in-line, one-way valves that prevent fuel from being siphoned back into an injector or injection pump which could delay a shutdown. There are two types of check valves: CKV2336 and CKV1WPS. The CKV2336 has a 1/4 NPT threaded male connection on each end for connecting to fuel line fittings or hoses. The CKV1WPS check valve is typically mounted in the fuel bypass line of the last fuel injector. The CKV1WPS features a hollow bolt connection and a barbed, 1/8 NPT connection for flex hose or fitting. The PRV series pressure relief valves, relieve overpressure in a fuel system usually caused by closing of a solenoid fuel valve. The PRV50 and PRV70 have a 1/4 NPT threaded connection on each end for connecting to fuel line fittings or hoses. Specifications Materials Note: Dimensions Opening Pressure Note: Static Pressure (all): 150 psi (1.03 MPa) maximum Weight: CKV2336: 1.3 oz (40.5 grams) CKV1WPS: 1.3 oz (40.5 grams) PRV50/PRV70: 1.3 oz (40.5 grams)

- 274 - Basic Operation Murphy Check Valves and Pressure Relief Valves enhance at the operation of diesel engine shutdown valves by reducing the time required for complete engine shutdown after the solenoid valve closes. The diagram to the right shows a typical installation using CKV check valves and PRV pressure relief valves. All valves are shown closed. Check Valves close off the fuel return line(s) to prevent fuel or air from re-entering the injection system through the bypass line(s). Models CKV2336 (3) is an in-line valve. Model CKV1WPS (2) has a 21/64 in. (8 mm) banjo fitting that attaches to the return line of the final injector. All check valves allow fuel to flow away from the injectors but close to prevent fuel from flowing in the reverse direction. The PRV50 and PRV70 (1) relieve pressure buildup in the fuel system that can cause fuel filter canisters to burst. When the solenoid valve closes to stop the engine, the fuel transfer pump will continue to produce pressure as the engine slows down to stop. This pressure buildup, if not relieved, can cause fuel filter canisters or gaskets to leak. PRV s are installed in the bypass line from the fuel filter(s) to the fuel return line. How to Order Specify model number: CKV2336 CKV1WPS PRV50 PRV70 Note: there are no replacement parts.

- 275 - Diesel-Fuel Shutoff Valves SV-Series 99026 Revised 08-07 Section 55 Features el Shutoff Valve or 24 VDC Models The SV-series valve is a normally closed valve that opens when current is supplied from the battery through a magnetic switch. Temperature, level, or pressure SWICHGAGE instruments installed on the engine and pump or compressor, trip the magnetic switch, breaking the circuit from the battery which closes the valve and stops the engine. The SV-12 valve operates on 12VDC, has a 1/4 NPT inlet and outlet, and a full 3/16 in. (5 mm) orifice. 24 VDC (SV-24) is optional The SV valves open against 30 psi. (207 kpa) [2.07 bar] inlet pressure. Greater Flow Rate Valve Special series SV valve is available with a 1/4 in. (6 mm) orifice which opens against maximum pressure of 15 psi (103 kpa) [1.03 bar]. This valve is recommended where greater flow is required, and only static head or low transfer pump pressures are encountered. High Pressure Valves SV-HP series valves open against diesel fuel transfer pump pressure up to 60 psi (414 kpa) [4.14 bar]. Models are available for 12 or 24 volt DC systems. The orifice is 1/4 in. (6 mm), using the same inlet/outlet and options as standard SV. Things You Should Know About SV-Series Valves The SV-Series fuel shutoff valve is intended for use with diesel engines having externally accessible fuel injection pumps. The volume of fuel required for the engine to operate must be able to pass through the 3/16 in. (5 mm) or 1/4 in. (6 mm) orifice of the valve. You must be able to attach the fuel valve directly onto or in close proximity to the fuel injection pump in order to close off fuel flow to the pump. SV-series is NOT intended for use with engines having unit injectors or distributor type injection pumps. Use only with diesel. Auxiliary Fuel Valves Fuel Return Line Check Valve The CKV series is an in-line, one-way valve for the prevention of fuel siphoning from the diesel return line by an injection pump. In engine shutdown systems using a Murphy SV valve, the CKV is necessary to ensure a rapid shut down of the engine by fuel starvation of the injection system. For details see bulletin CKV-7867B. Fuel Line Pressure Relief Valve The PRV50 is an in-line, one-way valve for the prevention of overpressure damage to fuel filters and their housings. This pressure relief valve operates in conjunction with a Murphy SV series shutdown valve; after the SV closes, a rapid high pressure build-up caused by the fuel pump can occur. The PRV, mounted in a fuel return line after the filter, will open to relieve pressure buildup.

- 276 - Typical SV Valve Installation Installation and Service Suggestions 1. Make sure the valve is the same voltage as the battery. Under continuous duty, the coil will normally be hot, however, incorrect voltage can cause smoking and burned coils. 2. The valve will not operate if the flow arrow on the side of the valve does not indicate the correct direction of flow. 3. Do not apply pipe dope to female valve threads. Dope inside the valve will foul the seat and prevent proper seal. 4. Install the valve as close as possible to the injection pump. Troubleshooting the SV-Series Valves Check Control Circuit: To determine if the electrical system is energizing the solenoid, listen for a metallic click signifying the solenoid is operating. Absence of the click indicates loss of power supply. Check for blown or loose fuses, for an open circuit or a grounded coil, for broken lead wires or open splice connections. Coil Burnout: Check for open-circuit coil. Replace coil if necessary. High or Low Voltage: Check voltage across the coil with a voltmeter. Voltage must be in 85% to 110% of nameplate rating. Incorrect Pressure: Check fuel line pressure. Pressure on the valve must be within the specific range of the SV in use.. Specifications NOTE: Mount the SV valve as close as possible to the injection pump. If using the SV valve with electronic devices, we recommend installing a suppression diode across the SV valve coil. Electrical Rating: 12 VDC, 10 watts Orifice: 3/16 in. (5 mm) diameter (optional 1/4 in. [6 mm] diameter). See chart below. Body Connections: 1/4 NPT inlet/outlet Maximum Opening Pressure: 3/16 in. (5 mm) orifice: 30 psi (207 kpa) [2.07 bar] 1/4 in. (6 mm) orifice: 15 psi (103 kpa) [1.03 bar] Shipping Weight: 1 lb. 6 oz. (0.68 kg) Shipping Dimension: 3 x 2-3/4 Sx 2-3/4 in. (76 x 70 x 70 mm) SV-HP (High Pressure model) Orifice: 1/4 in. (6 mm) diameter. See chart below. Maximum Opening Pressure: 60 psi (414 kpa) [4.14 bar]. Fuel Leak Through Valve: Disassemble the valve and clean parts. Replace any parts that are worn or damaged (see other side for repair parts). Slow Shutdown: Due to the internal fuel capacity of some injection pumps, engine shutdown will not occur until that fuel is used up Note: If engine continues to run after the valve closes, install a check valve such as CKV2336 in return line. Dimensions

- 277 - SV Repair Parts Callout Part Description Part Number A Screw 80-04-1412 B Coil Replacement Kit 12 volt kit 55-01-0141 B Coil Replacement Kit 24 volt kit 55-01-0145 C Core Repair Kit (Std mdls) 55-01-0155 C Core Repair Kit (HP mdls) 55-01-0156 D Valve Body: 3/16 Orifice 1/4 NPT x 1/4 NPT (std.) 55-05-0194 D Valve Body: 1/4 Orifice 1/4 NPT x 1/4 NPT 55-05-0193 How to Order See the diagram below, example: SV 12 HP SV Coil Voltage 12 = 12 VDC 24 = 24 VDC HP = High Pressure Orifice Blank (non- HP models) = 3/16 in. (5mm) dia. Blank ( HP models = 1/4 in. (6mm) dia. 4 = 1/4 in. (6mm) dia. (non- HP models only) CAUTION: Do NOT use the SV valves with distributor type injection pumps. For use with DIESEL ONLY.

- 278 - THIS PAGE INTENTIONALLY LEFT BLANK.

- 279-94134 Revised 07-99 Section 55 Electromechanical Fuel Shutoff Valves M25 and M50 Series Features gneto, CD Ignition or 12/24 VDC These fuel shutoff valves are semi-automatic devices for shutdown of natural gas fueled engines. The valve is opened manually and closes when the electromagnet is energized and trips the latch. The valve can be closed manually by turning the valve s disconnect knob. A normally energized model is available that holds the valve open electrically and closes when the coil is de-energized. A vent in the valve body relieves trapped gas when the valve closes. A pop-out indicator button informs you when the valve is open or closed. The valve s tripping power is provided by an engine ignition system or battery. Models are available for magneto, CD ignition or 12/24 V battery. The M2582 is a 1 inch (25 mm) valve with 1 NPT connections. It has one SPDT snap-switch. The valve body is made of sandcast aluminum. It does not include the open/close indicator button. M5081 is a 2 inch (51 mm) valve with 2 NPT connections. It has two SPDT snap-switches. The valve body is available in sandcast aluminum or cast steel (optional). M5081FS is the same as the M5081 but has a normally energized circuit. This circuit allows the valve to be held open electrically and close by interruption of the coil s power circuit. A manual trip knob is not available on this model. An optional 2 in. (51 mm) steel flange pipe connection is available for M5081 and M5081FS steel body models (see Dimensions page 3). Specifications Valve Body: Sandcast aluminum, painted red (corrosion resistance). Optional cast steel available for M5081 and M5081FS models only. Valve Seat: Buna-N Maximum Pressure Rating: Coil Rating: Intermittent duty; coil type must match power source; Wiring (See Internal Wiring page 2): Snap-switch Rating: 5 A @ 480 VAC Laboratory Approval: CSA listed for Class I, Groups C and D Hazardous Locations. 5 amps maximum; intermittent duty; models M5081 and M5081-CD engine ignition powered, and model M5081-B, 12 or 24 VAC or VDC; switch contacts rated 5 A @ 480 VAC maximum. Options and Accessories Diode Package (65010065) The Murphy 202 V diode package is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems. Sold separately (see How to Order). Magnetic Switch Adapter As ignition systems wear from usage their power output becomes less and less. Ignition may not have the capacity to reliably trip the fuel valve. Therefore, the use of a Magnetic Switch Adapter for CD ignition systems is recommended. The adapter stores energy from the CD ignition to trip the fuel valve. 65020126: For Negative Ground CD Ignitions up to 240 VDC 65020127: For Positive Ground CD Ignitions up to 450 VDC 65020155: For Negative Ground CD Ignitions 240 VDC to 450 VDC

- 280 - Flow Rates Internal Wiring M2582 M5081 and M5081FS NOTE: For grounding the ignition (CD models only) through the fuel valve s internal snap-switch, a Murphy Magnetic Switch adapter (see page 4) must be used in addition to a 100 ohm, 2 watt resistor (supplied with valve). NOTE: For grounding the ignition (CD models only) through the fuel valve s internal snap-switch, a Murphy Magnetic Switch adapter (see page 4) must be used in addition to a 100 ohm, 2 watt resistor (supplied with valve).

- 281 - Dimensions M2582 Steel Flanged Option 3 (available on M5081FS and M5081FS steel body configurations only) M5081 and M5081FS

- 282 - How to Order To order your valve, use the diagram below to specify your model and options. Example: M5081-A-2 Accessories Specify part number when ordering. Magnetic Switch Adapter 65020126: For Negative Ground CD Ignitions up to 240 VDC 65020127: For Positive Ground CD Ignitions up to 450 VDC 65020155: For Negative Ground CD Ignitions 240 VDC to 450 VDC Diode Package 65010065: For use with dual Magneto Ignition systems. Shipping Information Shipping Weights: Shipping Dimensions: Service Parts Specify part number when ordering.

- 283 - Pneumatic Valves for Fuel Gas Shutoff Models M2582-P and M5180-P 94129 08-07 Section 55

- 284 -

- 285 - Pulsation Dampener PD8100 Series 95145 Revised 12-03-10 Section 55 The PD8100 Series eliminates pointer flutter on pressure indicating SWICHGAGE devices which are subject to pulsating pressure from reciprocating pumps or compressors. It also allows a close setting of high and low contact points providing for more accurate pressure indication and control of equipment. The PD8100 Series decreases wear on geared movements and increases the life of pressure indicating instruments by eliminating excessive gage strain and unnecessary movement. A necessity which quickly pays for itself by protecting any pressure indicating and control instrument which is subject to pulsation. PD8100 SERIES NOT FOR USE ON OXYGEN OR LIQUID OXYGEN APPLICATIONS. Quality built with a large diameter valve stem wheel for ease of adjustment with clearly printed operating instructions. Machined from 1-3/8 in. (35 mm) hex bar stock. A two degree taper on valve and stem assure positive dampening. Available in brass, carbon steel, 303 stainless steel or 316 stainless steel to meet pressure and environmental requirements with either 1/2 NPT or 1/4 NPT inlet connections. Specifications See How to Order section for available inlet and outlet connections. PD8183: All wetted parts are Brass. Rated to 3,000 psi (20.68 MPa) [206.80 bar]. PD8184: All wetted parts are Carbon steel. Rated to 5,000 psi (34.47 MPa) [344.70 bar]. PD8185: All wetted parts are 303 stainless steel. Rated to 10,000 psi (68.95 MPa) [689.50 bar]. PD8190: All wetted parts are 316 stainless steel. Rated to 10,000 psi (68.95 MPa) [689.50 bar]. Meets NACE standard MR- 01-75 for direct exposure to H 2 S. Operating Temperature: -15 to 400 F (-26 to 204 C) Shipping Weight (all models): 2 lbs.(0.9 kgs.) Shipping Dimensions (all models): 4-3/4 x 4-3/4 x 3-1/4 in. (121 x 121 x 83 mm) Features Instruments and Recorders to Dampen Pressure Pulsation inter Flutter Accurate Pressure Indication Gage s Geared Movement NOT INTENDED FOR USE AS A SHUTOFF VALVE Dimensions

- 286 - Mounting for the OPLFC Pressure SWICHGAGE and PD8100 Series The PD8100 Series pulsation dampener is mounted directly below the OPLFC MURPHYMATIC Compressor Panel Shown at right, is a typical MURPHYMATIC compressor panel featuring three Pulsation Dampeners and Murphy s OPLFC gages. The PD's are recommended for use on piston pumps and compressors to eliminate pointer contact flutter and gage wear. Service Parts Precautions: Dope or use teflon tape on connection threads. Do not block the inlet orifice. How to Order